General Glass International Corp.: OSHA inspections and violations

Rockingham, North Carolina · Flat Glass Manufacturing · NAICS 327211

1inspections
3citation items
$2,400current penalties
Jan 11, 2024last inspection

OSHA has inspected General Glass International Corp. once in North Carolina.

The inspection began on Jan 11, 2024 as a planned inspection, in Rockingham.

That inspection ended with 3 citation items: 2 serious and 1 other-than-serious.

Penalties were first proposed at $2,400 and still stand at $2,400.

Belts, pulleys and power-transmission parts comes up most often in these citations: 2 items under 1910.219.

How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $4,500, and General Glass International Corp. averages $2,400 (1 cited inspection).

General Glass International Corp.: OSHA citation items per year, 2024 to 2024
Citation items per year, by inspection date.

North Carolina · latest 90 days of OSHA records

226employers cited

Get notified the morning OSHA posts each new citation in North Carolina: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in North Carolina

Checking a subcontractor, a client or your own company? Watch General Glass International Corp. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347207573 OPENED JAN 11, 2024Closed

Planned · Partial · Safety · 25 employees at the site · Closed Mar 25, 2024

208 Silver Grove Church Rd., Rockingham, NC 28379 · Flat Glass Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.219(d)(1) · Belts, pulleys and power-transmission parts
Serious$2,400$2,400Mar 6, 2024Final
Citation 1, item 1b
29 CFR 1910.219(e)(3)(i) · Belts, pulleys and power-transmission parts
Serious$0$0Mar 6, 2024Final
Citation 2, item 1
29 CFR 1910.303(b)(7) · Electrical equipment, general requirements
Other-than-serious$0$0Mar 6, 2024Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.219 · Belts, pulleys and power-transmission parts

29 CFR 1910.219(d)(1)

(d) Pulleys—(1) Guarding. Pulleys, any parts of which are seven (7) feet or less from the floor or working platform, shall be guarded in accordance with the standards specified in paragraphs (m) and (o) of this section. Pulleys serving as balance wheels (e.g., punch presses) on which the point of contact between belt and pulley is more than six feet six inches (6 ft. 6 in.) from the floor or platform may be guarded with a disk covering the spokes.

29 CFR 1910.219(e)(3)(i)

(3) Vertical and inclined belts. (i) Vertical and inclined belts shall be enclosed by a guard conforming to standards in paragraphs (m) and (o) of this section.

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.303(b)(7)

(7) Mechanical execution of work. Electric equipment shall be installed in a neat and workmanlike manner.

Other flat glass manufacturing employers in North Carolina

Alert subscribers get notified of each newly cited employer in North Carolina the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.