OSHA SearchOSHA records by employer

Genesis Electric & Home Improvement, LLC.: OSHA inspections and violations

Philadelphia, Pennsylvania · Other Building Equipment Contractors · NAICS 238290

1inspections
6citation items
$14,066current penalties
Apr 22, 2019last inspection

OSHA inspectors have visited Genesis Electric & Home Improvement, LLC. in Pennsylvania one time.

It opened on Apr 22, 2019 on a referral, in Philadelphia and is still open.

In all, OSHA issued 6 citation items: 6 serious.

The proposed penalties came to $18,754; today they stand at $14,066, 25% less.

The rule cited most here is 1926.453 (aerial lifts), 2 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Genesis Electric & Home Improvement, LLC. averages $14,066 across 1 cited inspection.

Genesis Electric & Home Improvement, LLC.: OSHA citation items per year, 2019 to 2019
Citation items per year, by inspection date.

Pennsylvania · latest 90 days of OSHA records

274employers cited

Get notified the morning OSHA posts each new citation in Pennsylvania: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Pennsylvania

Checking a subcontractor, a client or your own company? Watch Genesis Electric & Home Improvement, LLC. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343961868 OPENED APR 22, 2019Open

Referral · Partial · Safety · 3 employees at the site · Open

2045 Trenton Avenue, Philadelphia, PA 19125 · Other Building Equipment Contractors · OSHA's record · Phone and website on Google Maps

Incident on Apr 22, 2019: Employee is burned by high voltage electricity

At 9:00 a.m. on April 22, 2019, Employee #1, employed by an electrical contractor, was attempting to install an electrical cover over a high voltage electrical line. The employee came into contact with high voltage electricity. He was transported to the hospital and admitted for treatment of electrical burns.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.21(b)(2) · Construction safety training
Serious$3,978$2,984Sep 30, 2019Final
Citation 1, item 2
29 CFR 1926.95(a) · Criteria for personal protective equipment
Serious$3,978$2,984Sep 30, 2019Final
Citation 1, item 3a
29 CFR 1926.416(a)(1) · Electrical safety in construction
Serious$3,978$2,984Sep 30, 2019Final
Citation 1, item 3b
29 CFR 1926.416(a)(3) · Electrical safety in construction
Serious$0$0Sep 30, 2019Final
Citation 1, item 4
29 CFR 1926.453(b)(2)(v) · Aerial lifts
Serious$3,978$2,984Sep 30, 2019Final
Citation 1, item 5 Serious$2,842$2,132Sep 30, 2019Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.21 · Construction safety training

29 CFR 1926.21(b)(2)

(2) The employer shall instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his work environment to control or eliminate any hazards or other exposure to illness or injury.

29 CFR 1926.416 · Electrical safety in construction

29 CFR 1926.416(a)(1)

(a) Protection of employees. (1) No employer shall permit an employee to work in such proximity to any part of an electric power circuit that the employee could contact the electric power circuit in the course of work, unless the employee is protected against electric shock by deenergizing the circuit and grounding it or by guarding it effectively by insulation or other means.

29 CFR 1926.416(a)(3)

(3) Before work is begun the employer shall ascertain by inquiry or direct observation, or by instruments, whether any part of an energized electric power circuit, exposed or concealed, is so located that the performance of the work may bring any person, tool, or machine into physical or electrical contact with the electric power circuit. The employer shall post and maintain proper warning signs where such a circuit exists. The employer shall advise employees of the location of such lines, the hazards involved, and the protective measures to be taken.

29 CFR 1926.453 · Aerial lifts

29 CFR 1926.95 · Criteria for personal protective equipment

Other other building equipment contractors employers in Pennsylvania

Alert subscribers get notified of each newly cited employer in Pennsylvania the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.