OSHA SearchOSHA records by employer

Genon Mid-Atlantic, LLC. and Its Successors: OSHA inspections and violations

Aquasco, Maryland · Fossil Fuel Electric Power Generation · NAICS 221112

1inspections
3citation items
$0current penalties
Oct 2, 2018last inspection

OSHA has inspected Genon Mid-Atlantic, LLC. and Its Successors once in Maryland.

The inspection began on Oct 2, 2018 after a complaint, in Aquasco.

That inspection ended with 3 citation items: 3 other-than-serious.

None of the citations carried a penalty.

Respiratory protection comes up most often in these citations: 2 items under 1910.134.

How that compares: the median penalty per cited inspection for utility employers since 2015 is $0, and Genon Mid-Atlantic, LLC. and Its Successors averages $0 (1 cited inspection).

Genon Mid-Atlantic, LLC. and Its Successors: OSHA citation items per year, 2018 to 2018
Citation items per year, by inspection date.

Maryland · latest 90 days of OSHA records

191employers cited

Get notified the morning OSHA posts each new citation in Maryland: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Maryland

Checking a subcontractor, a client or your own company? Watch Genon Mid-Atlantic, LLC. and Its Successors and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343506077 OPENED OCT 2, 2018Closed

Complaint · Partial · Health · 132 employees at the site · Closed Mar 4, 2019

25100 Chalk Point Road, Aquasco, MD 20608 · Fossil Fuel Electric Power Generation · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.134(c)(1) · Respiratory protection
Other-than-serious$0$0Jan 22, 2019Final
Citation 1, item 2
29 CFR 1910.134(c)(3) · Respiratory protection
Other-than-serious$0$0Jan 22, 2019Final
Citation 1, item 3
29 CFR 1910.1020(g)(1) · Access to employee exposure and medical records
Other-than-serious$0$0Jan 22, 2019Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1020 · Access to employee exposure and medical records

29 CFR 1910.1020(g)(1)

(g) Employee information. (1) Upon an employee's first entering into employment, and at least annually thereafter, each employer shall inform current employees covered by this section of the following:

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.134(c)(1)

(1) The test instrument must have an effective audio-warning device, or a visual-warning device in the form of a screen tracing, that indicates when the test subject fails to hold his or her breath during the test. The test must be terminated and restarted from the beginning when the test subject fails to hold his or her breath during the test. The test subject then may be refitted and retested.

29 CFR 1910.134(c)(3)

(3) The test operator shall direct the stream of irritant smoke from the smoke tube toward the faceseal area of the test subject, using the low flow pump or the squeeze bulb. The test operator shall begin at least 12 inches from the facepiece and move the smoke stream around the whole perimeter of the mask. The operator shall gradually make two more passes around the perimeter of the mask, moving to within six inches of the respirator.

Other fossil fuel electric power generation employers in Maryland

Alert subscribers get notified of each newly cited employer in Maryland the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.