Since 1973, OSHA inspectors have visited Baltimore Gas and Electric Company in Maryland 105 times.
The most recent inspection opened on Jan 12, 2026 after a complaint, in Baltimore.
In all, OSHA issued 37 citation items: 24 serious, 1 repeat and 12 other-than-serious.
The proposed penalties came to $64,930; today they stand at $48,745, 25% less.
The rule cited most here is 1926.651 (excavations), 7 times.
Among utility employers, the typical cited inspection since 2015 ends with a $0 penalty. Baltimore Gas and Electric Company averages $2,322 across 6 cited inspections.
6 inspections on this page followed a fatal incident.
Baltimore Gas and Electric Company also files yearly injury logs with OSHA, summarized below.
97 older inspections
Inspection 343984068 OPENED MAY 3, 2019Closed
Accident · Partial · Safety · 17 employees at the site · Closed Jul 14, 2020
1700 Saint Andrews Way, Sykesville, MD 21784 · Electric Power Distribution · OSHA's record · Phone and website on Google Maps
Incident on May 3, 2019: Employee incurs burns when shocked while working on overhead
At 12:00 p.m. on May 03, 2019, an employee was part of a 14 man crew tasked to change over a section of electrical utility lines from overhead power lines to underground power lines. The employee and a coworker were working as one of three teams working at utility pole #551049. At the beginning, the employee and their trainee, the coworker, were together in the basket of a bucket truck. The employee was watching the coworker work as they made up lightning arrestors by connecting wires to them. After the coworker finished making up the arrestors, another coworker yelled up to the employee and coworker and told them the lines were energized. The employee and coworker then communicated to another coworker working on the pole that they could make the taps. The employee and coworker came down out of the area while the other coworker was making the taps. Something happened in regards to the neutral wire, so the employee and coworker went back up the pole to "dead end" the neutral wire. The coworker was performing the work on the neutral wire and the employee was in the bucket with them watching the work. The coworker took the clamps off of the concentrics that were attached to the neutral wire. Once the coworker finished their work they saw a flash and the employee slumped over. The coworker grabbed the controls and threw them down to the ground. The employee was admitted and treated at the hospital for 2nd degree burns to the left back shoulder and stomach.
No citations from this inspection.
Inspection 342546660 OPENED AUG 10, 2017Closed
Accident · Partial · Safety · 1 employee at the site · Closed Dec 7, 2017
5801 Smith Avenue, Baltimore, MD 21209 · Electric Power Distribution · OSHA's record · Phone and website on Google Maps
Incident on Aug 8, 2017: Employee receives electrical shock and burns to his arms
At 1:00 p.m. on August 8, 2018, an employee was working on a switch gear without wearing rubber sleeves or gloves. The employee received an electrical shock, burning his arms.
No citations from this inspection.
Inspection 342239159 OPENED APR 7, 2017Closed
Complaint · Partial · Safety · 36 employees at the site · Closed May 22, 2017
2900 Lord Baltimore Drive, Woodlawn, MD 21207 · Electric Power Distribution · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|
| Citation 1, item 1 |
Other-than-serious | $0 | $0 | May 4, 2017 | Final |
Inspection 317755270 OPENED APR 23, 2014Closed
Planned · Complete · Safety · 6 employees at the site · Closed Jul 23, 2014
3716 Washington Boulevard, Halethorpe, MD 21227 · Natural Gas Distribution · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|
| Citation 1, item 1 |
Other-than-serious | $1,350 | $945 | May 21, 2014 | Closed |
Inspection 314956152 OPENED OCT 14, 2010Closed
Planned · Partial · Safety · 3 employees at the site · Closed Sep 19, 2011
5684 The Alameda, Baltimore, MD 21239 · Electric Power Distribution · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Inspection 314564337 OPENED AUG 12, 2010Closed
Accident · Partial · Safety · 6 employees at the site · Closed Nov 5, 2010
Reidel Road, Crofton, MD 21114 · Electric Power Distribution · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Inspection 312269756 OPENED JUN 18, 2008Closed
Accident · Partial · Safety · 1 employee at the site · Closed Nov 13, 2008
Spout Hill Road & Springfield Road Substation, Sykesville, MD 21784 · Electric Power Distribution · OSHA's record · Phone and website on Google Maps
Incident on Jun 18, 2008 (fatal): Electrician working on high-voltage circuit is electrocuted
On June 18, 2008, an electrician entered the low voltage (up to 13-kv) side of a substation cabinet and removed two fuses. He was wearing fire retardant clothin g and high voltage sleeves and gloves. There was also voltage-testing equipment in the cabinet. He was found by a town police officer who was investigating a re port of someone yelling for help. The electrician may have contacted a bus bar w ith his back. The electrician's shirt was burned off in the back, and his pants were burned off in the front. He was responsive and told the officer he had blow n the feeder. The electrician was working alone. He died en route to the nearest medical facility of an electric shock of at least 7,620 volts.
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|
| Citation 1, item 1 |
Serious | $5,150 | $5,150 | Oct 3, 2008 | Closed |
Inspection 310900857 OPENED APR 9, 2007Closed
Accident · Partial · Safety · 2 employees at the site · Closed May 7, 2007
Annapolis Town Center/2300 Solomons Island Road, Annapolis, MD 21401 · Power, Distribution, and Specialty Transformer Manufacturing · OSHA's record · Phone and website on Google Maps
Incident on Apr 9, 2007: Employee is injured from contact with energized gear box
On April 9, 2007, Employee #1 was assigned to open and inspect a new unenergized switch gear box. However, Employee #1 mistakenly opened the wrong switch gear b ox, which was energized. As he contacted the energized box, Employee #1 received severe electrical shock injuries to his right wrist, left forearm, and his head , which required ten staples on the back of his head during hospitalization.
No citations from this inspection.
Inspection 308737626 OPENED MAY 16, 2005Closed
Accident · Partial · Safety · 1 employee at the site · Closed Jun 3, 2005
7223 Lee Deforest Drive, Columbia, MD 21046 · Electric Power Distribution · OSHA's record · Phone and website on Google Maps
Incident on May 15, 2005: Employee is shocked and burned
On May 15, 2005, Employee #1 was performing a scheduled monthly substation inspe ction. While inspecting Capacitor Bank Number 3-3, he observed a dead cat lying under the 7,600-volt phase A feed to reactor A. Employee #1 got the key for the gated capacitor bank, unlocked the gate, and entered the area. While inside the energized capacitor bank, Employee #1 contacted phase A and/or phase B. He recei ved an electrical shock, which rendered him temporarily unconscious and set his shirt on fire. Employees working nearby heard a loud noise and saw Employee #1 o n fire. They responded by putting out the fire with fire extinguishers and calli ng emergency services. Employee sustained burns to his face, chest, back and arm s. He was transported to a shock trauma center by helicopter.
No citations from this inspection.
Inspection 303542294 OPENED JUL 19, 2000Closed
Complaint · Partial · Health · 1,000 employees at the site · Closed Aug 8, 2000
G & E Building, 39 West Lexington Street, Baltimore, MD 21201 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|
| Citation 1, item 1 29 CFR 50104 A |
Serious | $4,325 | $4,325 | Apr 14, 2000 | Closed |
Incident on Jul 22, 1998: Two employees burned in gas main fire
On July 22, 1998, Employee #1, a contracted inspector, was overseeing work in an area where a company and its subcontractor were encapsulating the joints on a 1 6 in. medium-pressure gas main. The approximately 5 ft long by 4 ft wide by 4 1/ 2 ft deep trench had been opened on July 21. On that same day, a leak had been d iscovered in the joint near the T-connection on the gas main inside the hole. Th e hole was covered with a steel plate overnight so that the gas main could be re paired the next day. At approximately 11:00 p.m., Employee #1 was working inside the trench where he was preparing to take out the existing T-connection. He had just removed it when he heard the hissing sound of escaping natural gas. As he got the new T partially connected, a second hissing sound was heard and flames e ngulfed the hole. Employee #1 suffered second- and third-degree burns to his nec k, torso, and upper and lower extremities. Employee #2 sustained minor burns to his arms while trying to pull Employee #1 out of the hole. The cause of the fire is not known, but Employee #1 stated that neither the metallic piping nor the p lastic piping that he was working on that night were bonded to provide electrica l continuity and prevent the buildup of a static charge. Also, a Regent quartz h alogen light, model TQS 1000, was positioned on the ground at the top of the hol e to provide light. Quartz halogen lights are not designed for a Class I Divisio n I hazardous atmosphere. The metal housing on the quartz halogen light reaches temperatures as high as 140 degrees C (284 degrees F), and the outside surface o f the lens gets as hot as 300 degrees C (572 degrees F).
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|
| Citation 1, item 1 29 CFR 50104 A |
Serious | $4,500 | $2,000 | Jan 12, 1999 | Closed |
| Citation 1, item 2 29 CFR 50104 A |
Serious | $2,000 | $2,000 | Jan 12, 1999 | Closed |
| Citation 2, item 1 |
Serious | $0 | $0 | Jan 12, 1999 | Closed |
| Citation 3, item 1 |
Serious | $0 | $0 | Jan 12, 1999 | Closed |
| Citation 4, item 1 |
Serious | $1,000 | $1,000 | Jan 12, 1999 | Closed |
| Citation 5, item 1 |
Serious | $3,500 | $3,500 | Jan 12, 1999 | Closed |
| Citation 6, item 1 |
Serious | $0 | $0 | Jan 12, 1999 | Closed |
| Citation 7, item 1 |
Other-than-serious | $0 | $0 | Jan 12, 1999 | Closed |
Inspection 302024476 OPENED MAY 5, 1998Closed
Unprogrammed related · Complete · Safety · 1 employee at the site · Closed Jun 23, 1998
Painters Mill Road & Lakeside Blvd., Owings Mills, MD 21117 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
No citations from this inspection.
Incident on Aug 16, 1996: Electric shock - contact with overhead line thru boom
A power line worker in an aerial lift was transferring an overhead power line fr om one set of utility poles to another. As he was removing a 7620-volt (phase-to -ground) power line, the line contacted a metal screw on the aerial lift. The em ployee received an electric shock through the D-ring on his body belt and lost c onsciousness. He also sustained a burn at his waist line. He was hospitalized fo r his injuries.
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|
| Citation 1, item 1 |
Serious | $3,625 | $1,800 | Dec 6, 1996 | Closed |
Incident on Apr 26, 1996: Electric shock - direct contact with energized parts
Two power line workers were assigned to work on a new single-phase, pad-mounted transformer. The employees arrived at the jobsite at 10:00 AM. While they were r emoving the #1 and #2 elbows, the probes broke off the elbows. They tested both legs at the locations indicated by the feeder print and found the circuit to be deenergized at those locations. However, a line to the transformer was energized from a circuit not shown on the feeder print. The transformer elbow remained en ergized, and it is believed that the tester being used did not make contact insi de the elbow with the conductor lug. Believing from these tests that the line wa s deenergized, one of the power line workers removed his rubber insulating glove s and received a severe electric shock when he contacted the 7620-volt line. He was hospitalized for his injury.
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|
| Citation 1, item 1 |
Serious | $2,150 | $1,075 | Aug 21, 1996 | Closed |
No citations from this inspection.
Inspection 119538551 OPENED NOV 10, 1994Closed
Planned · Complete · Safety · 100 employees at the site · Closed Nov 16, 1994
Ne Corner Of Rosewood Lane & Reistertown Road, Owings Mills, MD 21117 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
No citations from this inspection.
No citations from this inspection.
Incident on Aug 18, 1993: Burn - electrical fault in live-line tool
A power line crew for an electric utility was phasing an electric generator to a power line. A nylon screw in the test stick failed, causing an electrical fault . The ensuing electric arc burned five of the employees; one of them was severel y burned. Four of the five employees were hospitalized for their injuries. The c rew was well trained and qualified to perform this job. The crew members were we aring proper personal protective equipment, which, in most cases, prevented more severe injury.
No citations from this inspection.
No citations from this inspection.
Incident on May 25, 1993: Electric shock - direct contact with energized conductor
A power line worker for an electric utility was repairing a defective transforme r. He was working between grounds and was wearing electrical protective equipmen t. He tested the system to ensure that it had been deenergized in accordance wit h his employer's tagging system. When he found the lines to be deenergized, he r emoved his electrical protective equipment and removed the test probe from the d efective elbow terminator. He received a very strong dc electric shock and was k nocked to the ground. He was hospitalized for his injury. The transformer had be en energized by another crew working in the same location. They had been testing for defective cables, apparently using cable fault locating equipment. The cabl e that they were testing was mismarked when it was installed. It was connected t o the transformer on which the injured employee had been working.
No citations from this inspection.
Inspection 104366794 OPENED OCT 21, 1992Closed
Planned · Complete · Safety · 4 employees at the site · Closed Oct 27, 1992
Wolfe & Fleet Streets, Baltimore, MD 21231 · Natural Gas Distribution · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Incident on May 18, 1992 (fatal): Electric shock - direct contact with overhead line
TWO POWER LINE WORKERS WERE ON A UTILITY POLE, PREPARING THE POLE FOR THE CONNEC TION OF AN UNDERGROUND FEEDER. ONE OF THE POWER LINE WORKERS HAD COMPLETED MEASU RING AND CUTTING TAPS FOR THE CROSSARM ON HIS LEFT. AS HE SHIFTED TO WORK ON HIS RIGHT SIDE, HE CONTACTED THE 7620-VOLT B-PHASE TAP WITH THE BACK OF HIS NECK. H E WAS ELECTROCUTED. THE EMPLOYEE WAS WEARING PERSONAL PROTECTIVE EQUIPMENT AT TH E TIME OF THE ACCIDENT. HE HAD BEEN TRAINED TO PERFORM THIS WORK AND HAD BEEN WO RKING FOR HIS EMPLOYER (AN ELECTRIC UTILITY) FOR 2 YEARS.
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|
| Citation 1, item 1 |
Serious | $7,900 | $0 | Nov 18, 1992 | Closed |
Incident on Feb 29, 1992 (fatal): Fall from scaffold
TWO MAINTENANCE WORKERS FOR AN ELECTRIC UTILITY WERE REMOVING 6-INCH-DIAMETER Y' S IN A ROOF DRAIN SYSTEM. THE THREE PIPES GOING INTO ONE OF THE Y'S WERE CUT WIT H A TORCH, AND A COME-ALONG WAS USED TO LOWER THE Y TO THE PLATFORM ON A SCAFFOL D. THE SCAFFOLD WAS 18.5 FEET HIGH. IT HAD BEEN PLACED ON AN AISLE THAT WAS 9 FE ET ABOVE THE NEXT LOWER ROOF LEVEL. THE SCAFFOLD HAD A PROPER GUARDRAIL AND LADD ER. THEY THEN USED A CHAINFALL TO RAISE THE Y OVER THE SCAFFOLD'S GUARDRAIL AND LOWER IT TO THE GROUND. AS THE Y WAS BEING RAISED OVER THE GUARDRAIL, ONE OF THE TWO EMPLOYEES CLIMBED DOWN THE SCAFFOLD. THE OTHER EMPLOYEE WAS MANIPULATING TH E CHAINFALL. WHEN THE EMPLOYEE WHO CLIMBED DOWN THE SCAFFOLD GOT TO THE BOTTOM, HE HEARD A THUD ON THE ROOF LEVEL BELOW AND SAW HIS COWORKER LYING THERE. THE EM PLOYEE HAD FALLEN OFF THE SCAFFOLD. HE DIED OF INJURIES SUSTAINED IN THE FALL.
No citations from this inspection.
No citations from this inspection.
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|
| Citation 1, item 1 |
Repeat | $6,200 | $6,200 | Mar 11, 1992 | Closed |
| Citation 2, item 1 |
Serious | $2,600 | $2,600 | Mar 11, 1992 | Closed |
| Citation 3, item 1 29 CFR 50405 B02 |
Serious | $230 | $230 | Mar 11, 1992 | Closed |
| Citation 4, item 1 |
Other-than-serious | $0 | $0 | Mar 11, 1992 | Closed |
| Citation 4, item 2 |
Other-than-serious | $0 | $0 | Mar 11, 1992 | Closed |
Incident on Nov 20, 1991: Burn - electrical fault in switchgear
A power line worker was assigned by his supervisor to go to a jobsite to work on an electric switchgear. He was trying to identify conductors running from the s witchgear to a pit where his crew leader was working. The crew leader instructed the power line worker to go to another compartment in the switchgear and set up an I.P.D. tester to check another set of conductors. An electric arc occurred ( the cause of which was not reported). The power line worker was burned on his ri ght arm, his chest, and his face. He was transported by helicopter to a burn cen ter, where he was hospitalized for his injuries.
No citations from this inspection.
Incident on Jun 17, 1991 (fatal): Employee killed when struck by vehicle
Employee #1 was conducting corrosion tests on gas mains in various areas and roa dways. Upon arriving at a work area, he would turn on the van's rear flashers, t he overhead flashing bubble light, and the arrow board. On the day of the accide nt, Employee #1 turned on all of the lights, got out of the van, walked around t o the rear, and opened the doors. He was approximately 4 ft from the rear of the van when he was struck by an oncoming car and thrown against the back of the va n. Employee #1 was flown to a trauma center, where he died of multiple injuries. Employee #1 was wearing a safety vest. He had not put out traffic cones for the 5 minute operation because his employer required cones only for jobs lasting mo re than 15 minutes. The driver of the car said that he never saw Employee #1 and was focused on avoiding the van. The police ruled the accident was the result o f driver error.
No citations from this inspection.
No citations from this inspection.
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|
| Citation 1, item 1 |
Other-than-serious | $0 | $0 | Jun 26, 1991 | Closed |
| Citation 1, item 2 |
Other-than-serious | $0 | $0 | Jun 26, 1991 | Closed |
No citations from this inspection.
No citations from this inspection.
No citations from this inspection.
No citations from this inspection.
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|
| Citation 1, item 1 |
Other-than-serious | $0 | $0 | Dec 14, 1990 | Closed |
No citations from this inspection.
Inspection 104442017 OPENED JUL 17, 1990Closed
Accident · Complete · Safety · 11 employees at the site · Closed Nov 29, 1990
Cypress Creek Road & B & A Boulevard, Severna Park, MD 21146 · OSHA's record · Phone and website on Google Maps
Incident on Jul 16, 1990: Electric shock - contact with overhead line
A power line crew was moving an overhead power line, including installing new ut ility poles about 4.3 meters from the roadway and installing new conductors. Thr ee employees on the crew were working from aerial lifts, and the rest of the emp loyees were on the ground. One of the employees cut a deenergized conductor at o ne end and started lowering it to the ground. This created slack in the conducto r about 120 meters away and caused the conductor to contact an energized line. A power line worker on the ground, who was not wearing rubber insulating gloves t hough he had been trained in their use, grabbed the conductor and sustained an e lectric shock and burns. He was hospitalized for his injuries.
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|
| Citation 1, item 1 |
Serious | $660 | $660 | Nov 5, 1990 | Closed |
Incident on Apr 30, 1990: Burn - electrical fault in switchgear
A traveling substation operator and a trainee stopped at a substation to perform a routine check of the station. On their arrival, they found a substation maint enance technician checking the air circuit breakers. The maintenance worker aske d the substation operator to remove a spare air circuit breaker from a 5000-volt Westinghouse metal-clad switchgear cubicle so that it could be checked. When th e 2.3- to 4.15-kilovolt, 600-ampere air circuit breaker (Model No. 50 H 150, man ufactured in 1946) was removed from the cubicle, the employees discovered that t he contact finger cluster was missing from the C phase bus bushing. The substati on operator opened the shutter to check for the missing part inside the cubicle. When he tried to close the shutters, they jammed. He applied pressure to free t he shutters, and an electrical fault occurred. The employees were burned by the ensuing electric arc, and they suffered from smoke inhalation. (The original abs tract indicated that the burns were to the face, neck, chest, and legs, but did not indicate who was burned where.) The employees were hospitalized for their in juries.
No citations from this inspection.
No citations from this inspection.
Incident on Jan 19, 1990: Electric shock - direct contact with overhead line
A POWER LINE WORKER FOR AN ELECTRIC UTILITY WAS WORKING ON AN OVERHEAD POWER LIN E FROM THE BUCKET OF AN AERIAL LIFT. THE EMPLOYEE HAD RECEIVED TRAINING IN SAFE WORK PRACTICES AND IN THE USE OF PERSONAL PROTECTIVE EQUIPMENT. HE WORE HIS RUBB ER INSULATING GLOVES AND SLEEVES WHILE HE PERFORMED HIS WORK. ONCE HIS TASK WAS COMPLETED AND AFTER HE HAD CONNECTED THE FUSE TO ENERGIZE THE SERVICE CONDUCTORS , HE REMOVED HIS GLOVES AND FOR SOME REASON GRABBED THE 7620-VOLT OVERHEAD POWER LINE. HE RECEIVED AN ELECTRIC SHOCK AND SERIOUS BURNS ON BOTH HANDS AND ARMS. H E WAS HOSPITALIZED FOR HIS INJURIES.
No citations from this inspection.
No citations from this inspection.
No citations from this inspection.
Inspection 108416090 OPENED OCT 31, 1989Closed
Planned · Complete · Safety · 3 employees at the site · Closed Nov 1, 1989
Old Columbia Pike & Cooks Lane, Ellicott City, MD 21043 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Incident on Sep 21, 1989: Electric shock - direct contact with overhead line
AN EMPLOYEE WAS CONNECTING ELECTRICAL POWER TO A TRAFFIC SIGNAL. HE USED AN AERI AL LIFT TO RAISE HIMSELF INTO POSITION. HE WAS HOLDING A TRIPLEX CABLE, ONE END OF WHICH WAS LYING ON THE GROUND, IN HIS LEFT HAND AS HE WENT UP IN THE LIFT. WI TH HIS ATTENTION FOCUSED ON THE CABLE AS HE WAS MOVING INTO POSITION, HE RAISED HIMSELF INTO CONTACT WITH A 7620-VOLT OVERHEAD POWER LINE. THE CABLE, WHICH HAD ONE UNINSULATED CONDUCTOR, PROVIDED A PATH TO GROUND. THE EMPLOYEE RECEIVED AN E LECTRIC SHOCK AND SEVERE BURNS TO HIS RIGHT EAR AND LEFT HAND. THE EMPLOYEE WAS HOSPITALIZED FOR HIS INJURIES.
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|
| Citation 1, item 1 |
Serious | $650 | $650 | Nov 8, 1989 | Closed |
No citations from this inspection.
No citations from this inspection.
Inspection 108433137 OPENED MAY 24, 1989Closed
Planned · Complete · Safety · 4 employees at the site · Closed May 25, 1989
Priest Bridge Substation, Belair Drive & Route 301, Bowie, MD 20715 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Incident on May 13, 1989 (fatal): Electric shock - direct contact with energized parts
A SERVICE OPERATOR TRAINER FOR AN ELECTRIC UTILITY WAS WATCHING A SERVICE OPERAT OR TRAINEE USE A LOAD BUSTER AND HOT STICK TO DISENGAGE AN ENERGIZED 7620-VOLT S WITCH ON A PAD-MOUNTED 13-KILOVOLT SWITCHGEAR. THE TRAINER WAS NOT WEARING ELECT RICAL PROTECTIVE EQUIPMENT, BUT THE TRAINEE WAS WEARING RUBBER INSULATING GLOVES AND SLEEVES. AFTER THE SWITCH WAS DISENGAGED BUT STILL ENERGIZED, THE TRAINEE T RIED TO REMOVE THE LOAD BUSTER TOOL FROM THE SWITCH BY TURNING THE HOT STICK. FO R SOME REASON, THE LOAD BUSTER BUTTON WAS NOT LOCKED IN THE HOT STICK HOLE, AND THE STICK TURNED WITHOUT MOVING THE LOAD BUSTER. THE TRAINER PUT HIS RIGHT HAND ON THE STICK TO REATTACH THE STICK TO THE LOAD BUSTER. HIS HAND CONTACTED THE EN ERGIZED LOAD BUSTER. THE TRAINER RECEIVED AN ELECTRIC SHOCK, AND THE POINTS OF C URRENT ENTRY AND EXIT WERE HIS HANDS AND FEET. DESPITE RESCUE EFFORTS BY COWORKE RS, PARAMEDICS, AND HOSPITAL STAFF, THE TRAINER DIED OF ELECTROCUTION.
No citations from this inspection.
No citations from this inspection.
No citations from this inspection.
Incident on Dec 15, 1988: Electric shock - contact with energized parts
A power line worker with 18 years of experience with an electric utility was a c rew leader for an electrical construction crew. The crew was installing addition al transformers and a 13-kilovolt feeder at a secured substation. The modificati ons were necessary to upgrade the capacity of the substation because of growth i n the area. During the installation process, the crew used a Westinghouse mobile transformer to meet the demand on the substation. The crew leader was absent fr om the jobsite the morning of the accident. During his absence, problems develop ed with the mobile unit. The problem was handled by distribution personnel withi n the utility company. Upon his return, the crew leader observed the troubleshoo ting activity and offered his assistance. When the mobile unit was reactivated, a problem arose with the grounding apparatus on the unit. The crew leader climbe d the structure of the unit and apparently slipped. He came too close to an ener gized insulator at the 33-kilovolt end of the unit and caused an electrical faul t. The employee received an electric shock and suffered burns to both arms and t o his left ear from the ensuing electric arc. He was hospitalized for his injuri es and had to undergo mental and physical therapy. The employee did not remember the accident afterwards.
No citations from this inspection.
Inspection 104375191 OPENED OCT 6, 1988Closed
Planned · Complete · Safety · 6 employees at the site · Closed Dec 1, 1988
Old Taneytown Road & Baugher Road, Westminster, MD 21157 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
No citations from this inspection.
Inspection 104392774 OPENED SEP 15, 1988Closed
Accident · Partial · Safety · 1,000 employees at the site · Closed Nov 18, 1988
Calvert Cliffs Nuclear Power Plant, Lusby, MD 20657 · OSHA's record · Phone and website on Google Maps
Incident on Sep 15, 1988 (fatal): Diver killed, another suffers asphyxia in confined space
Some electric utility employees were assigned to repair a level switch mechanism inside a 1136-kiloliter make-up water tank (condensate tank #11). The project r equired entry by a diver using a self-contained underwater breathing apparatus i nto the tank. Employee #2, the diver, obtained a diving permit and was evaluatin g means of entry as a predive drill to determine whether he could enter the manh ole with his tanks and scuba or if they would have to be passed down to him afte r entry. He was wearing a lifeline when he went down the fixed ladder and into t he tank. After he descended 203 millimeters, he was overcome and fell into the w ater. The diver tenders (Employee #1 and another employee) were holding the life line but could not see Employee #2 in the tank. Employee #1 entered the tank in an apparent rescue operation. He was not wearing a lifeline, nor was he using re lated emergency rescue equipment. The second diver tender, who was still holding the lifeline attached to Employee #2, yelled for assistance and, with the help of three coworkers, was able to raise Employee #2 to the bottom of the manhole o pening. Since the line was around his lower chest, Employee #2's body was in a h orizontal position, and the other employees had to reposition his body at an ang le. The employees successfully completed the rescue and revived Employee #2 by a dministering cardio-pulmonary resuscitation. However, they could not see Employe e #1 at this time. They summoned a professional diver, who found Employee #1 at the bottom of the tank. He had been asphyxiated. Employee #2 was hospitalized fo r his injuries. The dive team was not aware that a nitrogen blanket was in the s pace above the water. The team had not tested the atmosphere for oxygen. Employe es were trained in confined space entry, but were not following entry procedures . In addition, the team had not obtained a confined-space permit, which would ha ve required air monitoring from the Fire and Safety Department.
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|
| Citation 1, item 1 29 CFR 890032 A |
Serious | $660 | $1,000 | Oct 25, 1988 | Closed |
Inspection 104379466 OPENED AUG 31, 1988Closed
Unprogrammed related · Partial · Safety · 75 employees at the site · Closed Sep 20, 1988
900 Block, Moores Mill Road, Bel Air, MD 21014 · OSHA's record · Phone and website on Google Maps
Incident on Aug 23, 1988: Eye flash - looked at electric arc
An employee of a temporary employment service was a flagger on a line-clearance tree-trimming job performed jointly by an electric utility and a tree service fi rm. The employees were trimming trees around a 33-kilovolt overhead power line l ocated 12.2 meters above the ground. The tree-trimming crew was working from a 1 9.8-meter-high HiRanger aerial lift. The crew noticed that a 20-millimeter-diame ter, 1.2-meter-long branch had fallen out of the tree onto the power line. The l ines faulted before the branch could be removed and a massive electric arc ensue d because of a recloser malfunction. The flagger, who was looking at the branch when the fault occurred, sustained an eye flash injury. She was hospitalized for her injury.
No citations from this inspection.
No citations from this inspection.
No citations from this inspection.
No citations from this inspection.
No citations from this inspection.
No citations from this inspection.
No citations from this inspection.
No citations from this inspection.
No citations from this inspection.
Inspection 104403878 OPENED MAR 16, 1988Closed
Complaint · Partial · Health · 1,800 employees at the site · Closed Mar 23, 1988
Liberty & Lexington Streets, Baltimore, MD 21201 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
No citations from this inspection.
No citations from this inspection.
Inspection 104412598 OPENED JAN 7, 1988Closed
Planned · Complete · Safety · 3 employees at the site · Closed Jan 20, 1988
College Parkway & Jones Station Road, Arnold, MD 21012 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
No citations from this inspection.
No citations from this inspection.
No citations from this inspection.
No citations from this inspection.
No citations from this inspection.
No citations from this inspection.
Inspection 14824437 OPENED FEB 19, 1987Closed
Planned · Complete · Safety · 2 employees at the site · Closed Feb 27, 1987
Woodbridge Center Way & Windy Branch Way, Edgewood, MD 21040 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|
| Citation 1, item 1 |
Serious | $560 | $560 | May 1, 1987 | Closed |
| Citation 2, item 1 |
Other-than-serious | $0 | $0 | May 1, 1987 | Closed |
No citations from this inspection.
No citations from this inspection.
No citations from this inspection.
No citations from this inspection.
Inspection 18871764 OPENED NOV 10, 1986Closed
Planned · Complete · Safety · 4 employees at the site · Closed Nov 20, 1986
East Main Street & Washington Road, Westminster, MD 21157 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Inspection 102037934 OPENED NOV 6, 1986Closed
Planned · Complete · Safety · 5 employees at the site · Closed Nov 13, 1986
Whispering Hills Development, Leeward Way, Westminster, MD 21157 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Inspection 102037819 OPENED OCT 17, 1986Closed
Planned · Complete · Safety · 4 employees at the site · Closed Nov 4, 1986
Old Taneytown Pike & Clearview Road, Westminster, MD 21157 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
No citations from this inspection.
No citations from this inspection.
Inspection 18872028 OPENED AUG 27, 1986Closed
Planned · Complete · Safety · 7 employees at the site · Closed Oct 30, 1986
I-83 South Extension & Baltimore Street, Baltimore, MD 21202 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Inspection 102037645 OPENED AUG 22, 1986Closed
Planned · Complete · Safety · 5 employees at the site · Closed Aug 29, 1986
Railroad Avenue & East Main Street, Westminster, MD 21157 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
No citations from this inspection.
Inspection 2806339 OPENED JAN 31, 1986Closed
Accident · Partial · Safety · 2 employees at the site · Closed Mar 21, 1986
State Highway Administration, 2323 W Joppa Road, Lutherville, MD 21093 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Inspection 2820967 OPENED AUG 29, 1985Closed
Referral · Partial · Health · 50 employees at the site · Closed Aug 30, 1985
Westport Power Station, 2101 Kloman Street, Baltimore, MD 21230 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
No citations from this inspection.
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|
| Citation 1, item 1 |
Serious | $620 | $620 | Nov 10, 1983 | Closed |
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|
| Citation 1, item 1 29 CFR 890032 A |
Serious | $500 | $500 | Oct 14, 1983 | Closed |
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|
| Citation 1, item 1 |
Other-than-serious | $0 | $0 | Mar 23, 1983 | Closed |
| Citation 1, item 2 |
Other-than-serious | $0 | $0 | Mar 23, 1983 | Closed |
No citations from this inspection.
No citations from this inspection.
From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.
In 2024, the Baltimore site logged 17 recordable injuries or illnesses among about 751 workers: 2.1 per 100 full-time workers, against a median of 1.0 for its industry. Those cases cost 254 days away from work.
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
Alert subscribers get notified of each newly cited employer in Maryland the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.