OSHA SearchOSHA records by employer

Geo Home Renovations Inc.: OSHA inspections and violations

Athens, New York · Roofing Contractors · NAICS 238160

1inspections
12citation items
$53,460current penalties
Apr 18, 2024last inspection

Geo Home Renovations Inc. has one OSHA inspection on record in New York.

OSHA opened it on Apr 18, 2024 on a referral, in Athens, and the case has not closed yet.

From that inspection OSHA issued 12 citation items: 10 serious and 2 other-than-serious.

OSHA proposed $53,460 in penalties and the amount has not been reduced.

Most often, OSHA cited 1926.451, scaffolds, general requirements (7 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Geo Home Renovations Inc. averages $53,460 over 1 cited inspection in that time.

Geo Home Renovations Inc.: OSHA citation items per year, 2024 to 2024
Citation items per year, by inspection date.

New York · latest 90 days of OSHA records

372employers cited

60 of them in the same industry

Get notified the morning OSHA posts each new citation in New York: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in New York

Checking a subcontractor, a client or your own company? Watch Geo Home Renovations Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347423634 OPENED APR 18, 2024Open

Referral · Partial · Safety · 11 employees at the site · Open

21 2nd Street, Athens, NY 12015 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(b)(5)(ii) · Scaffolds, general requirements
Serious$6,452$6,452Oct 7, 2024Final
Citation 1, item 2
29 CFR 1926.451(b)(10) · Scaffolds, general requirements
Serious$6,452$6,452Oct 7, 2024Final
Citation 1, item 3
29 CFR 1926.451(e)(8) · Scaffolds, general requirements
Serious$6,452$6,452Oct 7, 2024Final
Citation 1, item 4a
29 CFR 1926.451(f)(6) · Scaffolds, general requirements
Serious$6,452$6,452Oct 7, 2024Final
Citation 1, item 4b
29 CFR 1926.451(f)(7) · Scaffolds, general requirements
Serious$0$0Oct 7, 2024Final
Citation 1, item 5a
29 CFR 1926.454(a) · Scaffold training
Serious$6,452$6,452Oct 7, 2024Final
Citation 1, item 5b
29 CFR 1926.454(b) · Scaffold training
Serious$0$0Oct 7, 2024Final
Citation 1, item 6
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$6,452$6,452Oct 7, 2024Final
Citation 1, item 7
29 CFR 1926.451(g)(4)(i) · Scaffolds, general requirements
Serious$6,452$6,452Oct 7, 2024Final
Citation 1, item 8
29 CFR 1926.452(j)(2) · Rules for each type of scaffold
Serious$6,452$6,452Oct 7, 2024Final
Citation 2, item 1
29 CFR 1904.29(a) · Injury and illness log
Other-than-serious$922$922Oct 7, 2024Final
Citation 2, item 2
29 CFR 1904.40(a) · Giving injury records to OSHA
Other-than-serious$922$922Oct 7, 2024Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1904.29 · Injury and illness log

29 CFR 1904.29(a)

(a) Basic requirement. You must use OSHA 300, 300-A, and 301 forms, or equivalent forms, for recordable injuries and illnesses. The OSHA 300 form is called the Log of Work-Related Injuries and Illnesses, the 300-A is the Summary of Work-Related Injuries and Illnesses, and the OSHA 301 form is called the Injury and Illness Incident Report.

29 CFR 1904.40 · Giving injury records to OSHA

29 CFR 1904.40(a)

(a) Basic requirement. When an authorized government representative asks for the records you keep under part 1904, you must provide copies of the records within four (4) business hours.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(10)

(10) Scaffold components manufactured by different manufacturers shall not be intermixed unless the components fit together without force and the scaffold's structural integrity is maintained by the user. Scaffold components manufactured by different manufacturers shall not be modified in order to intermix them unless a competent person determines the resulting scaffold is structurally sound.

29 CFR 1926.452 · Rules for each type of scaffold

29 CFR 1926.454 · Scaffold training

Other roofing contractors employers in New York

Alert subscribers get notified of each newly cited employer in New York the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.