OSHA SearchOSHA records by employer

Georator Corporation: OSHA inspections and violations

Manassas, Virginia · Motor and Generator Manufacturing · NAICS 335312

4inspections
14citation items
$2,920current penalties
Feb 7, 2018last inspection

Georator Corporation has 4 OSHA inspections on record in Virginia, the first in 1994.

OSHA's last visit started on Feb 7, 2018 as a planned inspection, in Manassas.

Across those inspections OSHA issued 14 citation items: 13 serious and 1 other-than-serious.

OSHA proposed $3,100 in penalties. After settlements and reviews the total is $2,920, down 6%.

Most often, OSHA cited 1910.134, respiratory protection (4 items).

For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $3,600. Georator Corporation averages $2,400 over 1 cited inspection in that time.

Georator Corporation: OSHA citation items per year, 1994 to 2018
Citation items per year, by inspection date.

Virginia · latest 90 days of OSHA records

246employers cited

Get notified the morning OSHA posts each new citation in Virginia: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Virginia

Checking a subcontractor, a client or your own company? Watch Georator Corporation and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342931243 OPENED FEB 7, 2018Closed

Planned · Complete · Safety · 15 employees at the site · Closed Jun 25, 2018

9617 Center Street, Manassas, VA 20110 · Motor and Generator Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 2
29 CFR 1910.147(c)(1) · Lockout/tagout
Serious$600$600Apr 23, 2018Final
Citation 1, item 3
29 CFR 1910.179(j)(3) · Overhead and gantry cranes
Serious$600$600Apr 23, 2018Final
Citation 1, item 4
29 CFR 1910.305(b)(1)(ii) · Electrical wiring methods
Serious$600$600Apr 23, 2018Final
Citation 1, item 5
29 CFR 1910.1200(h)(3)(iv) · Hazard communication
Serious$600$600Apr 23, 2018Final
Citation 2, item 1
29 CFR 1910.107(b)(9) · Spray painting and finishing
Other-than-serious$0$0Apr 23, 2018Final

Inspection 340142942 OPENED DEC 17, 2014Closed

Planned · Complete · Safety · 15 employees at the site · Closed Dec 17, 2014

9617 Center Street, Manassas, VA 20110 · Motor and Generator Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 313185829 OPENED APR 28, 2009Closed

Planned · Complete · Safety · 15 employees at the site · Closed Jul 16, 2009

9617 Center Street, Manassas, VA 22110 · Motor and Generator Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.134(c)(1) · Respiratory protection
Serious$225$135May 21, 2009Closed
Citation 1, item 1b
29 CFR 1910.134(e)(1) · Respiratory protection
Serious$0$0May 21, 2009Closed
Citation 1, item 1c
29 CFR 1910.134(f)(2) · Respiratory protection
Serious$0$0May 21, 2009Closed
Citation 1, item 1d
29 CFR 1910.134(k)(1)(i) · Respiratory protection
Serious$0$0May 21, 2009Closed
Citation 1, item 2
29 CFR 1910.212(a)(1) · Machine guarding
Serious$225$135May 21, 2009Closed

Inspection 123685687 OPENED NOV 22, 1994Closed

Planned · Complete · Safety · 20 employees at the site · Closed Mar 15, 1995

9617 Center Street, Manassas, VA 22110 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.212(a)(1) · Machine guarding
Serious$125$125Feb 3, 1995Closed
Citation 1, item 2a
29 CFR 1910.303(b)(2) · Electrical equipment, general requirements
Serious$125$125Feb 3, 1995Closed
Citation 1, item 2b
29 CFR 1910.304(a)(2) · Grounding and circuit protection
Serious$0$0Feb 3, 1995Closed
Citation 1, item 2c
29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods
Serious$0$0Feb 3, 1995Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.107 · Spray painting and finishing

29 CFR 1910.107(b)(9)

(9) Cleaning. Spray booths shall be so installed that all portions are readily accessible for cleaning. A clear space of not less than 3 feet on all sides shall be kept free from storage or combustible construction.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(h)(3)(iv)

(iv) The details of the hazard communication program developed by the employer, including an explanation of the labels received on shipped containers and the workplace labeling system used by their employer; the safety data sheet, including the order of information and how employees can obtain and use the appropriate hazard information.

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.134(c)(1)

(1) The test instrument must have an effective audio-warning device, or a visual-warning device in the form of a screen tracing, that indicates when the test subject fails to hold his or her breath during the test. The test must be terminated and restarted from the beginning when the test subject fails to hold his or her breath during the test. The test subject then may be refitted and retested.

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.179 · Overhead and gantry cranes

29 CFR 1910.212 · Machine guarding

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.304 · Grounding and circuit protection

29 CFR 1910.305 · Electrical wiring methods

Other motor and generator manufacturing employers in Virginia

Alert subscribers get notified of each newly cited employer in Virginia the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.