OSHA SearchOSHA records by employer

Gerardo Escobar: OSHA inspections and violations

Garland, Texas · Drywall and Insulation Contractors · NAICS 238310

1inspections
2citation items
$10,922current penalties
May 6, 2021last inspection

OSHA inspectors have visited Gerardo Escobar in Texas one time.

It opened on May 6, 2021 as a planned inspection, in Garland.

In all, OSHA issued 2 citation items: 2 serious.

The penalties, $10,922 in total, stand where OSHA first set them.

Among construction employers, the typical cited inspection since 2015 ends with a $3,079 penalty. Gerardo Escobar averages $10,922 across 1 cited inspection.

Gerardo Escobar: OSHA citation items per year, 2021 to 2021
Citation items per year, by inspection date.

Want to know if OSHA cites Gerardo Escobar again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 345294128 OPENED MAY 6, 2021Closed

Planned · Complete · Safety · 12 employees at the site · Closed Jun 25, 2024

3400 Firewheel Pkwy., Garland, TX 75046 · Drywall and Insulation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(b)(8) · Scaffolds, general requirements
Serious$5,461$5,461Jul 16, 2021Final
Citation 1, item 2
29 CFR 1926.452(c)(2) · Rules for each type of scaffold
Serious$5,461$5,461Jul 16, 2021Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(8)

(8) At all points of a scaffold where the platform changes direction, such as turning a corner, any platform that rests on a bearer at an angle other than a right angle shall be laid first, and platforms which rest at right angles over the same bearer shall be laid second, on top of the first platform.

29 CFR 1926.452 · Rules for each type of scaffold

29 CFR 1926.452(c)(2)

(2) Frames and panels shall be braced by cross, horizontal, or diagonal braces, or combination thereof, which secure vertical members together laterally. The cross braces shall be of such length as will automatically square and align vertical members so that the erected scaffold is always plumb, level, and square. All brace connections shall be secured.

Other drywall and insulation contractors employers in Texas

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.