OSHA SearchOSHA records by employer

Gervais Goulet: OSHA inspections and violations

Rocky Hill, Connecticut · Roofing Contractors · NAICS 238160

1inspections
5citation items
$8,000current penalties
Mar 29, 2018last inspection

OSHA has inspected Gervais Goulet once in Connecticut.

The inspection began on Mar 29, 2018 after a complaint, in Rocky Hill.

That inspection ended with 5 citation items: 5 serious.

Penalties were first proposed at $17,184 and now stand at $8,000, 53% lower after settlements or reviews.

Scaffolds, general requirements comes up most often in these citations: 4 items under 1926.451.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Gervais Goulet averages $8,000 (1 cited inspection).

Gervais Goulet: OSHA citation items per year, 2018 to 2018
Citation items per year, by inspection date.

Connecticut · latest 90 days of OSHA records

86employers cited

4 of them in the same industry

Get notified the morning OSHA posts each new citation in Connecticut: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Connecticut

Checking a subcontractor, a client or your own company? Watch Gervais Goulet and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343048971 OPENED MAR 29, 2018Closed

Complaint · Partial · Safety · 2 employees at the site · Closed Jun 18, 2018

2270 Silas Deane Highway, Rocky Hill, CT 06067 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(a)(1) · Scaffolds, general requirements
Serious$3,880$1,600May 11, 2018Final
Citation 1, item 2
29 CFR 1926.451(a)(6) · Scaffolds, general requirements
Serious$3,880$1,600May 11, 2018Final
Citation 1, item 3
29 CFR 1926.451(c)(2)(v) · Scaffolds, general requirements
Serious$2,772$1,600May 11, 2018Final
Citation 1, item 4
29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements
Serious$2,772$1,600May 11, 2018Final
Citation 1, item 5
OSH Act Section 5(a)(1) · General Duty Clause
Serious$3,880$1,600May 11, 2018Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(a)(1)

(a) Capacity. (1) Except as provided in paragraphs (a)(2), (a)(3), (a)(4), (a)(5) and (g) of this section, each scaffold and scaffold component shall be capable of supporting, without failure, its own weight and at least 4 times the maximum intended load applied or transmitted to it.

29 CFR 1926.451(a)(6)

(6) Scaffolds shall be designed by a qualified person and shall be constructed and loaded in accordance with that design. Non-mandatory appendix A to this subpart contains examples of criteria that will enable an employer to comply with paragraph (a) of this section.

29 CFR 1926.451(c)(2)(v)

(v) Fork-lifts shall not be used to support scaffold platforms unless the entire platform is attached to the fork and the fork-lift is not moved horizontally while the platform is occupied.

OSH Act Section 5 · General Duty Clause

Other roofing contractors employers in Connecticut

Alert subscribers get notified of each newly cited employer in Connecticut the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.