OSHA SearchOSHA records by employer

Gibson County Utility District - Maintenance: OSHA inspections and violations

Trenton, Tennessee · Natural Gas Distribution · NAICS 221210

2inspections
9citation items
$0current penalties
Sep 14, 2021last inspection

OSHA has inspected Gibson County Utility District - Maintenance 2 times in Tennessee since 2019.

The latest one began on Sep 14, 2021 as a planned inspection, in Trenton.

Those inspections ended with 9 citation items: 9 serious.

None of the citations carried a penalty.

Lockout/tagout comes up most often in these citations: 2 items under 1910.147.

How that compares: the median penalty per cited inspection for utility employers since 2015 is $0, and Gibson County Utility District - Maintenance averages $0 (2 cited inspections).

Gibson County Utility District - Maintenance: OSHA citation items per year, 2019 to 2021
Citation items per year, by inspection date.

Tennessee · latest 90 days of OSHA records

339employers cited

4 of them in the same industry

Get notified the morning OSHA posts each new citation in Tennessee: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Tennessee

Checking a subcontractor, a client or your own company? Watch Gibson County Utility District - Maintenance and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 345528111 OPENED SEP 14, 2021Closed

Planned · Complete · Safety · Local government · 39 employees at the site · Closed Oct 11, 2021

1300 N. Highway Bypass, Trenton, TN 38382 · Natural Gas Distribution · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.37(b)(2) · Exit routes
Serious$0$0Sep 17, 2021Final
Citation 1, item 2
29 CFR 1910.178(p)(1) · Forklifts and other powered industrial trucks
Serious$0$0Sep 17, 2021Final
Citation 1, item 3
29 CFR 1910.244(a)(1)(ii) · Other portable tools and equipment
Serious$0$0Sep 17, 2021Final

Inspection 344413729 OPENED OCT 30, 2019Closed

Planned · Complete · Safety · Local government · 21 employees at the site · Closed Nov 26, 2019

1300 Us Hwy 45 By-pass N, Trenton, TN 38382 · Natural Gas Distribution · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.147(c)(1) · Lockout/tagout
Serious$0$0Nov 4, 2019Final
Citation 1, item 2
29 CFR 1910.147(c)(7)(i) · Lockout/tagout
Serious$0$0Nov 4, 2019Final
Citation 1, item 3
29 CFR 1910.303(f)(2) · Electrical equipment, general requirements
Serious$0$0Nov 4, 2019Final
Citation 1, item 4
29 CFR 1910.305(b)(1) · Electrical wiring methods
Serious$0$0Nov 4, 2019Final
Citation 1, item 5
29 CFR 1910.1030(c)(1)(iv) · Bloodborne pathogens
Serious$0$0Nov 4, 2019Final
Citation 1, item 6
29 CFR 1910.1200(f)(6)(ii) · Hazard communication
Serious$0$0Nov 4, 2019Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1030 · Bloodborne pathogens

29 CFR 1910.1030(c)(1)(iv)

(iv) The Exposure Control Plan shall be reviewed and updated at least annually and whenever necessary to reflect new or modified tasks and procedures which affect occupational exposure and to reflect new or revised employee positions with occupational exposure. The review and update of such plans shall also:

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(f)(6)(ii)

(ii) Product identifier and words, pictures, symbols, or combination thereof, which provide at least general information regarding the hazards of the chemicals, and which, in conjunction with the other information immediately available to employees under the hazard communication program, will provide employees with the specific information regarding the physical and health hazards of the hazardous chemical.

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.147(c)(1)

(c) General—(1) Energy control program. The employer shall establish a program consisting of energy control procedures, employee training and periodic inspections to ensure that before any employee performs any servicing or maintenance on a machine or equipment where the unexpected energizing, start up or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source, and rendered inoperative.

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.244 · Other portable tools and equipment

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.37 · Exit routes

Other natural gas distribution employers in Tennessee

Alert subscribers get notified of each newly cited employer in Tennessee the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.