OSHA SearchOSHA records by employer

Gleason Reel Corp: OSHA inspections and violations

Mayville, Wisconsin · Instruments and Related Products Manufacturing for Measuring, Displaying, and Controlling Industrial Process Variables · NAICS 334513

4inspections
12citation items
$13,626current penalties
Nov 22, 2019last inspection

Gleason Reel Corp has 4 OSHA inspections on record in Wisconsin, the first in 1988.

OSHA's last visit started on Nov 22, 2019 as a planned inspection, in Mayville.

Across those inspections OSHA issued 12 citation items: 10 serious and 2 other-than-serious.

OSHA proposed $23,212 in penalties. After settlements and reviews the total is $13,626, down 41%.

Most often, OSHA cited 1910.217, mechanical power presses (3 items).

For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $3,600. Gleason Reel Corp averages $7,696 over 1 cited inspection in that time.

Gleason Reel Corp also files yearly injury logs with OSHA, summarized below.

Gleason Reel Corp: OSHA citation items per year, 1988 to 2019
Citation items per year, by inspection date.

Wisconsin · latest 90 days of OSHA records

228employers cited

Get notified the morning OSHA posts each new citation in Wisconsin: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Wisconsin

Checking a subcontractor, a client or your own company? Watch Gleason Reel Corp and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 344467774 OPENED NOV 22, 2019Closed

Planned · Partial · Safety · 67 employees at the site · Closed Dec 4, 2019

600 S. Clark Street, Mayville, WI 53050 · Instruments and Related Products Manufacturing for Measuring, Displaying, and Controlling Industrial Process Variables · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 342406683 OPENED JUN 20, 2017Closed

Complaint · Partial · Safety · 172 employees at the site · Closed Dec 28, 2017

600 S. Clark Street, Mayville, WI 53050 · Instruments and Related Products Manufacturing for Measuring, Displaying, and Controlling Industrial Process Variables · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.147(c)(4)(i) · Lockout/tagout
Serious$7,696$7,696Oct 26, 2017Final
Citation 1, item 1b
29 CFR 1910.333(a) · Working near live electrical parts
Serious$7,696$0Oct 26, 2017Final

Inspection 310763065 OPENED AUG 8, 2007Closed

Referral · Partial · Safety · 179 employees at the site · Closed Sep 12, 2007

600 S. Clark Street, Mayville, WI 53050 · All Other Miscellaneous Fabricated Metal Product Manufacturing · OSHA's record · Phone and website on Google Maps

Incident on Aug 1, 2007: Employee's hand is fractured in press brake

On August 1, 2007, Employee #1 was using a Cincinnati hydraulic press brake (Ser ial Number 47801) to form a part called a ratchet (Part Number 032039). The pres s brake was equipped with Link Lite Black Max light curtains (Model Number LL-MA X-18-AS, Serial Number 3962), but two of the photo eyes on these light curtains were blanked. This created a virtual opening of 1.5 inches in the light curtain beams. The light curtains were set back two inches away from the edge of the die s, and Employee #1's hand got caught between the dies when the press brake was c ycled using a foot pedal control. Employee #1 was hospitalized with a fracture.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.212(a)(3)(ii) · Machine guarding
Serious$6,300$4,410Aug 22, 2007Closed

Inspection 103145538 OPENED OCT 5, 1988Closed

Planned · Complete · Safety · 103 employees at the site · Closed Dec 7, 1988

600 S. Clark Street, Mayville, WI 53050 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.106(d)(2)(i) · Flammable liquids
Serious$320$320Oct 27, 1988Closed
Citation 1, item 1b
29 CFR 1910.106(d)(4)(i) · Flammable liquids
Serious$0$0Oct 27, 1988Closed
Citation 1, item 1c
29 CFR 1910.106(e)(2)(ii) · Flammable liquids
Serious$0$0Oct 27, 1988Closed
Citation 1, item 2
29 CFR 1910.212(a)(1) · Machine guarding
Serious$320$320Oct 27, 1988Closed
Citation 1, item 3a
29 CFR 1910.217(d)(9)(iv) · Mechanical power presses
Serious$400$400Oct 27, 1988Closed
Citation 1, item 3b
29 CFR 1910.217(e)(1)(ii) · Mechanical power presses
Serious$0$0Oct 27, 1988Closed
Citation 1, item 4
29 CFR 1910.304(f)(4)(iv) · Grounding and circuit protection
Serious$480$480Oct 27, 1988Closed
Citation 2, item 1
29 CFR 1910.217(b)(4)(i) · Mechanical power presses
Other-than-serious$0$0Oct 27, 1988Closed
Citation 2, item 2
29 CFR 1910.212(a)(1) · Machine guarding
Other-than-serious$0$0Oct 27, 1988Closed

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2025, the Mayville site logged 1 recordable injury or illness among about 130 workers: 0.8 per 100 full-time workers, against a median of 2.4 for its industry.

Site and yearWorkersCasesDays-away casesRateIndustry median
Gleason Reel
Mayville · 2025
130 100.82.4
Gleason Reel Corp
Mayville · 2016
145 704.92.4

Included with any plan: 8 more yearly logs from these sites, back to 2016, with each site's average rate over its latest three years. Already a subscriber? Sign in.

See plans

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.106 · Flammable liquids

29 CFR 1910.106(d)(2)(i)

(2) Design, construction, and capacity of containers—(i) General. Only approved containers and portable tanks shall be used. Metal containers and portable tanks meeting the requirements of and containing products authorized by chapter I, title 49 of the Code of Federal Regulations (regulations issued by the Hazardous Materials Regulations Board, Department of Transportation), shall be deemed to be acceptable.

29 CFR 1910.106(d)(4)(i)

(4) Design and construction of inside storage rooms—(i) Construction. Inside storage rooms shall be constructed to meet the required fire-resistive rating for their use. Such construction shall comply with the test specifications set forth in Standard Methods of Fire Tests of Building Construction and Materials, NFPA 251-1969. Where an automatic sprinkler system is provided, the system shall be designed and installed in an acceptable manner. Openings to other rooms or buildings shall be provided with noncombustible liquid-tight raised sills or ramps at least 4 inches in height, or the floor in the storage area shall be at least 4 inches below the surrounding floor. Openings shall be provided with approved self-closing fire doors. The room shall be liquid-tight where the walls join the floor. A permissible alternate to the sill or ramp is an open-grated trench inside of the room which dra

29 CFR 1910.106(e)(2)(ii)

(ii) Containers. Flammable liquids shall be stored in tanks or closed containers.

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.212 · Machine guarding

29 CFR 1910.217 · Mechanical power presses

29 CFR 1910.304 · Grounding and circuit protection

29 CFR 1910.333 · Working near live electrical parts

Other instruments and related products manufacturing for measuring, displaying, and controlling industrial process variables employers in Wisconsin

Alert subscribers get notified of each newly cited employer in Wisconsin the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.