OSHA SearchOSHA records by employer

Gonzalez Roofing: OSHA inspections and violations

Summerfield, North Carolina · Roofing Contractors · NAICS 238160

7inspections
6citation items
$5,650current penalties
Jun 7, 2024last inspection

Gonzalez Roofing has 7 OSHA inspections on record in North Carolina, the first in 2012.

OSHA's last visit started on Jun 7, 2024 after a complaint, in Durham.

Across those inspections OSHA issued 6 citation items: 6 serious.

OSHA proposed $8,550 in penalties. After settlements and reviews the total is $5,650, down 34%.

Most often, OSHA cited 1926.1053, ladders in construction (2 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Gonzalez Roofing averages $2,825 over 2 cited inspections in that time.

Gonzalez Roofing: OSHA citation items per year, 2012 to 2024
Citation items per year, by inspection date.

Want to know if OSHA cites Gonzalez Roofing again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 347536229 OPENED JUN 7, 2024Closed

Complaint · No inspection · Safety · Closed Jun 10, 2024

1816 Front Street, Durham, NC 27705 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 346803307 OPENED JUN 28, 2023Closed

Planned · Complete · Health · 5 employees at the site · Closed Sep 7, 2023

7604 Skippers Trace, Oak Ridge, NC 27310 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 346792765 OPENED JUN 26, 2023Closed

Planned · Complete · Health · 5 employees at the site · Closed Oct 31, 2023

7634 Braelands Drive, Summerfield, NC 27358 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.20(b)(2) · Construction safety programs
Serious$3,000$1,950Jul 21, 2023Final

Inspection 346157019 OPENED AUG 17, 2022Closed

Planned · No inspection · Safety · Closed Sep 23, 2022

8308 Coldwater Road, Stokesdale, NC 27357 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 344820410 OPENED JUL 1, 2020Closed

Planned · Complete · Health · 5 employees at the site · Closed Jan 6, 2021

6833 Shields Drive, Oak Ridge, NC 27310 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$2,100$1,386Oct 5, 2020Final
Citation 1, item 1b
29 CFR 1926.503(b)(1) · Fall protection training in construction
Serious$0$0Oct 5, 2020Final
Citation 1, item 2
29 CFR 1926.1053(b)(1) · Ladders in construction
Serious$1,500$990Oct 5, 2020Final
Citation 1, item 3
29 CFR 1926.1053(b)(16) · Ladders in construction
Serious$450$334Oct 5, 2020Final
Citation 1, item 4
29 CFR 1926.1060(a) · Ladder and stairway training
Serious$1,500$990Oct 5, 2020Final

Inspection 341573285 OPENED JUN 23, 2016Closed

Unprogrammed other · Partial · Safety · 1 employee at the site · Closed Jul 6, 2016

7499 Shadow Creek Dr, Summerfield, NC 27358 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 316247857 OPENED JAN 30, 2012Closed

Planned · Partial · Safety · 1 employee at the site · Closed Feb 14, 2012

Lot 80 Jessup Ridge, 8312 Lilly's Cr, Greensboro, NC 27455 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(1)

(1) When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.

29 CFR 1926.1053(b)(16)

(16) Portable ladders with structural defects, such as, but not limited to, broken or missing rungs, cleats, or steps, broken or split rails, corroded components, or other faulty or defective components, shall either be immediately marked in a manner that readily identifies them as defective, or be tagged with “Do Not Use” or similar language, and shall be withdrawn from service until repaired.

29 CFR 1926.1060 · Ladder and stairway training

29 CFR 1926.1060(a)

(a) The employer shall provide a training program for each employee using ladders and stairways, as necessary. The program shall enable each employee to recognize hazards related to ladders and stairways, and shall train each employee in the procedures to be followed to minimize these hazards.

29 CFR 1926.20 · Construction safety programs

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.503 · Fall protection training in construction

Other roofing contractors employers in North Carolina

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.