OSHA SearchOSHA records by employer

Good Paint LLC: OSHA inspections and violations

Commercy City, Colorado · Paint and Coating Manufacturing · NAICS 325510

2inspections
8citation items
$3,600current penalties
Jun 12, 2019last inspection

Since 1999, OSHA inspectors have visited Good Paint LLC in Colorado 2 times.

The most recent inspection opened on Jun 12, 2019 after a complaint, in Commerce City.

In all, OSHA issued 8 citation items: 7 serious and 1 other-than-serious.

The proposed penalties came to $5,796; today they stand at $3,600, 38% less.

The rule cited most here is 1910.134 (respiratory protection), 3 times.

Among manufacturing employers, the typical cited inspection since 2015 ends with a $4,500 penalty. Good Paint LLC averages $3,600 across 1 cited inspection.

Good Paint LLC: OSHA citation items per year, 1999 to 2019
Citation items per year, by inspection date.

Colorado · latest 90 days of OSHA records

134employers cited

Get notified the morning OSHA posts each new citation in Colorado: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Colorado

Checking a subcontractor, a client or your own company? Watch Good Paint LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 344074489 OPENED JUN 12, 2019Closed

Complaint · Partial · Health · 18 employees at the site · Closed Feb 10, 2020

6292 Colorado Blvd, Commerce City, CO 80022 · Paint and Coating Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Serious$1,932$1,200Aug 14, 2019Final
Citation 1, item 2a
29 CFR 1910.134(c)(1) · Respiratory protection
Serious$1,932$1,200Aug 14, 2019Final
Citation 1, item 2b
29 CFR 1910.134(d)(1)(iii) · Respiratory protection
Serious$0$0Aug 14, 2019Final
Citation 1, item 2c
29 CFR 1910.134(e)(1) · Respiratory protection
Serious$0$0Aug 14, 2019Final
Citation 1, item 2d
29 CFR 1910.1000(a) · Air contaminants
Serious$0$0Aug 14, 2019Final
Citation 1, item 2e
29 CFR 1910.1000(e) · Air contaminants
Serious$0$0Aug 14, 2019Final
Citation 1, item 3
29 CFR 1910.1200(h)(1) · Hazard communication
Serious$1,932$1,200Aug 14, 2019Final
Citation 2, item 1
29 CFR 1910.107(b)(5)(i) · Spray painting and finishing
Other-than-serious$0$0Aug 14, 2019Final

Inspection 302072566 OPENED JAN 28, 1999Closed

Planned · No inspection · Health · 3 employees at the site · Closed Jan 28, 1999

5720 Holly Street, Unit D-e, Commercy City, CO 80022 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1000 · Air contaminants

29 CFR 1910.1000(e)

(e) To achieve compliance with paragraphs (a) through (d) of this section, administrative or engineering controls must first be determined and implemented whenever feasible. When such controls are not feasible to achieve full compliance, protective equipment or any other protective measures shall be used to keep the exposure of employees to air contaminants within the limits prescribed in this section. Any equipment and/or technical measures used for this purpose must be approved for each particular use by a competent industrial hygienist or other technically qualified person. Whenever respirators are used, their use shall comply with 1910.134.

29 CFR 1910.107 · Spray painting and finishing

29 CFR 1910.107(b)(5)(i)

(i) The spraying operations except electrostatic spraying operations shall be so designed, installed and maintained that the average air velocity over the open face of the booth (or booth cross section during spraying operations) shall be not less than 100 linear feet per minute. Electrostatic spraying operations may be conducted with an air velocity over the open face of the booth of not less than 60 linear feet per minute, or more, depending on the volume of the finishing material being applied and its flammability and explosion characteristics. Visible gauges or audible alarm or pressure activated devices shall be installed to indicate or insure that the required air velocity is maintained. Filter rolls shall be inspected to insure proper replacement of filter media.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(h)(1)

(h) Employee information and training. (1) Employers shall provide employees with effective information and training on hazardous chemicals in their work area at the time of their initial assignment, and whenever a new chemical hazard the employees have not previously been trained about is introduced into their work area. Information and training may be designed to cover categories of hazards (e.g., flammability, carcinogenicity) or specific chemicals. Chemical-specific information must always be available through labels and safety data sheets.

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.95 · Noise

Other paint and coating manufacturing employers in Colorado

Alert subscribers get notified of each newly cited employer in Colorado the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.