OSHA SearchOSHA records by employer

Grandland Group (Cnmi) Ltd.: OSHA inspections and violations

Saipan, Northern Mariana Islands · Commercial and Institutional Building Construction · NAICS 236220

1inspections
6citation items
$5,817current penalties
Aug 10, 2017last inspection

OSHA inspectors have visited Grandland Group (Cnmi) Ltd. in Northern Mariana Islands one time.

It opened on Aug 10, 2017 as a planned inspection, in Saipan.

In all, OSHA issued 6 citation items: 4 serious and 2 other-than-serious.

The proposed penalties came to $8,310; today they stand at $5,817, 30% less.

The rule cited most here is 1926.350 (gas welding and cutting), 2 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Grandland Group (Cnmi) Ltd. averages $5,817 across 1 cited inspection.

The Wage and Hour Division has 1 case on it since 2015, with $202,440 in back wages owed to workers.

Grandland Group (Cnmi) Ltd.: OSHA citation items per year, 2017 to 2017
Citation items per year, by inspection date.

Northern Mariana Islands · latest 90 days of OSHA records

7employers cited

5 of them in the same industry

Get notified the morning OSHA posts each new citation in Northern Mariana Islands: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Northern Mariana Islands

Checking a subcontractor, a client or your own company? Watch Grandland Group (Cnmi) Ltd. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342534880 OPENED AUG 10, 2017Closed

Planned · Complete · Safety · 110 employees at the site · Closed Feb 20, 2018

Imperial Pacific Resort Hotel Saipan, Saipan, MP 96950 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.25(a) · Housekeeping
Serious$4,155$2,908Jan 3, 2018Final
Citation 1, item 1b
29 CFR 1926.701(b) · Concrete and Masonry Construction: general requirements
Serious$0$0Jan 3, 2018Final
Citation 1, item 2a
29 CFR 1926.350(a)(10) · Gas welding and cutting
Serious$4,155$2,908Jan 3, 2018Final
Citation 1, item 2b
29 CFR 1926.350(a)(11) · Gas welding and cutting
Serious$0$0Jan 3, 2018Final
Citation 2, item 1
29 CFR 1926.405(g)(2)(iv) · Job-site wiring
Other-than-serious$0$0Jan 3, 2018Final
Citation 2, item 2
29 CFR 1926.416(e)(1) · Electrical safety in construction
Other-than-serious$0$0Jan 3, 2018Final

Wage and hour cases

Cases by the Labor Department's Wage and Hour Division since 2015: unpaid minimum wage or overtime, child labor, family leave and more.

Period reviewedViolationsWorkers owedBack wagesPenalties
Mar 8, 2016 to Sep 26, 2017
Saipan
342336$202,440$0

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.25 · Housekeeping

29 CFR 1926.25(a)

(a) During the course of construction, alteration, or repairs, form and scrap lumber with protruding nails, and all other debris, shall be kept cleared from work areas, passageways, and stairs, in and around buildings or other structures.

29 CFR 1926.350 · Gas welding and cutting

29 CFR 1926.350(a)(10)

(10) Oxygen cylinders in storage shall be separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hour.

29 CFR 1926.350(a)(11)

(11) Inside of buildings, cylinders shall be stored in a well-protected, well-ventilated, dry location, at least 20 feet (6.1 m) from highly combustible materials such as oil or excelsior. Cylinders should be stored in definitely assigned places away from elevators, stairs, or gangways. Assigned storage places shall be located where cylinders will not be knocked over or damaged by passing or falling objects, or subject to tampering by unauthorized persons. Cylinders shall not be kept in unventilated enclosures such as lockers and cupboards.

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.416 · Electrical safety in construction

29 CFR 1926.701 · Concrete and Masonry Construction: general requirements

Other commercial and institutional building construction employers in Northern Mariana Islands

Alert subscribers get notified of each newly cited employer in Northern Mariana Islands the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.