OSHA SearchOSHA records by employer

Granite Time Inc.: OSHA inspections and violations

Marble Falls, Texas · Cut Stone and Stone Product Manufacturing · NAICS 327991

1inspections
3citation items
$5,618current penalties
Sep 21, 2021last inspection

Granite Time Inc. has one OSHA inspection on record in Texas.

OSHA opened it on Sep 21, 2021 as a planned inspection, in Marble Falls.

From that inspection OSHA issued 3 citation items: 3 serious.

OSHA proposed $9,363 in penalties. After settlements and reviews the total is $5,618, down 40%.

For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $4,500. Granite Time Inc. averages $5,618 over 1 cited inspection in that time.

Granite Time Inc.: OSHA citation items per year, 2021 to 2021
Citation items per year, by inspection date.

Want to know if OSHA cites Granite Time Inc. again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 345540470 OPENED SEP 21, 2021Closed

Planned · Partial · Health · 2 employees at the site · Closed Mar 21, 2022

2302 Us Hwy 281 N, Marble Falls, TX 78654 · Cut Stone and Stone Product Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.134(c)(1) · Respiratory protection
Serious$4,096$2,458Dec 30, 2021Final
Citation 1, item 2
29 CFR 1910.178(l)(6) · Forklifts and other powered industrial trucks
Serious$2,341$1,405Dec 30, 2021Final
Citation 1, item 3
29 CFR 1910.1053(d)(1) · Silica dust in general industry
Serious$2,926$1,756Dec 30, 2021Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1053 · Silica dust in general industry

29 CFR 1910.1053(d)(1)

(d) Exposure assessment—(1) General. The employer shall assess the exposure of each employee who is or may reasonably be expected to be exposed to respirable crystalline silica at or above the action level in accordance with either the performance option in paragraph (d)(2) or the scheduled monitoring option in paragraph (d)(3) of this section.

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.134(c)(1)

(1) The test instrument must have an effective audio-warning device, or a visual-warning device in the form of a screen tracing, that indicates when the test subject fails to hold his or her breath during the test. The test must be terminated and restarted from the beginning when the test subject fails to hold his or her breath during the test. The test subject then may be refitted and retested.

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.178(l)(6)

(6) Certification. The employer shall certify that each operator has been trained and evaluated as required by this paragraph (l). The certification shall include the name of the operator, the date of the training, the date of the evaluation, and the identity of the person(s) performing the training or evaluation.

Other cut stone and stone product manufacturing employers in Texas

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.