Inspection 343095212 OPENED APR 17, 2018Closed
2501 Davis Creek Road, Seneca, SC 29678 · Cutlery and Handtool Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Seneca, South Carolina · Cutlery and Handtool Manufacturing · NAICS 332212
OSHA has inspected Greenfield Industries Inc 4 times in South Carolina since 1987.
The latest one began on Apr 17, 2018 to follow up on an earlier case, in Seneca.
Those inspections ended with 12 citation items: 10 serious and 2 other-than-serious.
Penalties were first proposed at $25,500 and now stand at $24,562, 4% lower after settlements or reviews.
Respiratory protection comes up most often in these citations: 6 items under 1910.134.
How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $3,600, and Greenfield Industries Inc averages $12,281 (2 cited inspections).
Greenfield Industries Inc also files yearly injury logs with OSHA, summarized below.
South Carolina · latest 90 days of OSHA records
42employers cited
Get notified the morning OSHA posts each new citation in South Carolina: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in South Carolina
Checking a subcontractor, a client or your own company? Watch Greenfield Industries Inc and get notified the morning OSHA posts a new citation for it.
Watch this company2501 Davis Creek Road, Seneca, SC 29678 · Cutlery and Handtool Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
2501 Davis Creek Road, Seneca, SC 29678 · Cutlery and Handtool Manufacturing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.147(c)(1) · Lockout/tagout |
Other-than-serious | $1,875 | $1,406 | May 16, 2017 | Final |
| Citation 1, item 2 29 CFR 1910.333(a) · Working near live electrical parts |
Serious | $1,875 | $1,406 | May 16, 2017 | Final |
2501 Davis Creek Road, Seneca, SC 29678 · Cutlery and Handtool Manufacturing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1.12(A) |
Serious | $2,625 | $2,625 | Sep 19, 2017 | Contested |
| Citation 1, item 2 29 CFR 1910.134(c)(1) · Respiratory protection |
Serious | $2,625 | $2,625 | Sep 19, 2017 | Contested |
| Citation 1, item 3 29 CFR 1910.134(d)(1)(i) · Respiratory protection |
Serious | $2,625 | $2,625 | Sep 19, 2017 | Contested |
| Citation 1, item 4 29 CFR 1910.134(e)(1) · Respiratory protection |
Serious | $2,625 | $2,625 | Sep 19, 2017 | Contested |
| Citation 1, item 5 29 CFR 1910.134(f)(1) · Respiratory protection |
Serious | $2,625 | $2,625 | Sep 19, 2017 | Contested |
| Citation 1, item 6 29 CFR 1910.134(k)(5) · Respiratory protection |
Serious | $2,625 | $2,625 | Sep 19, 2017 | Contested |
| Citation 1, item 7 29 CFR 1910.138(a) · Gloves and hand protection |
Serious | $2,625 | $2,625 | Sep 19, 2017 | Contested |
| Citation 1, item 8 29 CFR 1910.146(c)(1) · Permit-required confined spaces |
Serious | $1,875 | $1,875 | Sep 19, 2017 | Contested |
| Citation 1, item 9 29 CFR 1910.146(c)(2) · Permit-required confined spaces |
Serious | $1,500 | $1,500 | Sep 19, 2017 | Contested |
| Citation 2, item 1 29 CFR 1910.134(k)(6) · Respiratory protection |
Other-than-serious | $0 | $0 | Sep 19, 2017 | Contested |
Highway 123 West, Clemson, SC 29633 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.
In 2025, the Seneca site logged 7 recordable injuries or illnesses among about 326 workers: 2.3 per 100 full-time workers, against a median of 2.3 for its industry. Those cases cost 350 days away from work.
| Site and year | Workers | Cases | Days-away cases | Rate | Industry median |
|---|---|---|---|---|---|
| Greenfield Industries Seneca · 2025 | 326 | 7 | 5 | 2.3 | 2.3 |
| Greenfield Industries Inc. Seneca · 2019 | 316 | 7 | 1 | 2.3 | 2.3 |
Included with any plan: 3 more yearly logs from these sites, back to 2019, with each site's average rate over its latest three years. Already a subscriber? Sign in.
See plansCurrent text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1910.134(c)(1)
(1) The test instrument must have an effective audio-warning device, or a visual-warning device in the form of a screen tracing, that indicates when the test subject fails to hold his or her breath during the test. The test must be terminated and restarted from the beginning when the test subject fails to hold his or her breath during the test. The test subject then may be refitted and retested.
29 CFR 1910.134(d)(1)(i)
(1) General requirements. (i) The employer shall select and provide an appropriate respirator based on the respiratory hazard(s) to which the worker is exposed and workplace and user factors that affect respirator performance and reliability.
29 CFR 1910.134(e)(1)
(1) General. The employer shall provide a medical evaluation to determine the employee's ability to use a respirator, before the employee is fit tested or required to use the respirator in the workplace. The employer may discontinue an employee's medical evaluations when the employee is no longer required to use a respirator.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.