OSHA SearchOSHA records by employer

Greenwood Pallet Company Inc.: OSHA inspections and violations

Bridgeville, Delaware · Lumber, Plywood, Millwork, and Wood Panel Merchant Wholesalers · NAICS 423310

2inspections
14citation items
$41,702current penalties
Aug 24, 2016last inspection

Since 2016, OSHA inspectors have visited Greenwood Pallet Company Inc. in Delaware 2 times.

The most recent inspection opened on Aug 24, 2016 after a complaint, in Bridgeville.

In all, OSHA issued 14 citation items: 10 serious and 4 other-than-serious.

The proposed penalties came to $65,912; today they stand at $41,702, 37% less.

The rule cited most here is 1910.95 (noise), 3 times.

Among wholesale employers, the typical cited inspection since 2015 ends with a $3,427 penalty. Greenwood Pallet Company Inc. averages $20,851 across 2 cited inspections.

Greenwood Pallet Company Inc.: OSHA citation items per year, 2016 to 2016
Citation items per year, by inspection date.

Delaware · latest 90 days of OSHA records

31employers cited

Get notified the morning OSHA posts each new citation in Delaware: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Delaware

Checking a subcontractor, a client or your own company? Watch Greenwood Pallet Company Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 341723658 OPENED AUG 24, 2016Closed

Complaint · Partial · Health · 38 employees at the site · Closed Aug 14, 2017

16849 Road Runner Drive, Bridgeville, DE 19933 · Lumber, Plywood, Millwork, and Wood Panel Merchant Wholesalers · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.22(a)(1) · Walking-working surfaces
Serious$8,873$6,211Feb 16, 2017Final
Citation 1, item 1b
29 CFR 1910.307(c) · Hazardous (classified) locations
Serious$0$0Feb 16, 2017Final
Citation 1, item 2a Serious$3,802$2,661Feb 16, 2017Final
Citation 1, item 2b Serious$0$0Feb 16, 2017Final
Citation 1, item 3 Serious$3,802$2,661Feb 16, 2017Final

Inspection 341723997 OPENED AUG 24, 2016Closed

Complaint · Partial · Safety · 38 employees at the site · Closed Aug 14, 2017

16849 Road Runner Drive, Bridgeville, DE 19933 · Lumber, Plywood, Millwork, and Wood Panel Merchant Wholesalers · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.22(b)(1) · Walking-working surfaces
Other-than-serious$6,338$0Feb 16, 2017Final
Citation 1, item 2
29 CFR 1910.37(a)(3) · Exit routes
Serious$8,873$6,211Feb 16, 2017Final
Citation 1, item 3
29 CFR 1910.147(c)(4)(i) · Lockout/tagout
Serious$8,873$6,211Feb 16, 2017Final
Citation 1, item 4
29 CFR 1910.178(n)(4) · Forklifts and other powered industrial trucks
Serious$7,605$5,324Feb 16, 2017Final
Citation 1, item 5
29 CFR 1910.213(a)(9) · Woodworking machinery
Serious$8,873$6,211Feb 16, 2017Final
Citation 1, item 6
29 CFR 1910.303(g)(2)(i) · Electrical equipment, general requirements
Serious$8,873$6,211Feb 16, 2017Final
Citation 2, item 1 Other-than-serious$0$0Feb 16, 2017Final
Citation 2, item 2 Other-than-serious$0$0Feb 16, 2017Final
Citation 2, item 3
29 CFR 1910.178(l)(4)(iii) · Forklifts and other powered industrial trucks
Other-than-serious$0$0Feb 16, 2017Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.141 · Sanitation

29 CFR 1910.141(c)(1)(i)

(c) Toilet facilities—(1) General. (i) Except as otherwise indicated in this paragraph (c)(1)(i), toilet facilities, in toilet rooms separate for each sex, shall be provided in all places of employment in accordance with table J-1 of this section. The number of facilities to be provided for each sex shall be based on the number of employees of that sex for whom the facilities are furnished. Where toilet rooms will be occupied by no more than one person at a time, can be locked from the inside, and contain at least one water closet, separate toilet rooms for each sex need not be provided. Where such single-occupancy rooms have more than one toilet facility, only one such facility in each toilet room shall be counted for the purpose of table J-1.

29 CFR 1910.141(d)(2)(ii)

(ii) Each lavatory shall be provided with hot and cold running water, or tepid running water.

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.147(c)(4)(i)

(4) Energy control procedure. (i) Procedures shall be developed, documented and utilized for the control of potentially hazardous energy when employees are engaged in the activities covered by this section.

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.213 · Woodworking machinery

29 CFR 1910.22 · Walking-working surfaces

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.307 · Hazardous (classified) locations

29 CFR 1910.37 · Exit routes

29 CFR 1910.95 · Noise

Other lumber, plywood, millwork, and wood panel merchant wholesalers employers in Delaware

Alert subscribers get notified of each newly cited employer in Delaware the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.