OSHA SearchOSHA records by employer

Greg Weikle: OSHA inspections and violations

White Sulphur Springs, West Virginia · Residential Remodelers · NAICS 236118

1inspections
9citation items
$12,000current penalties
Apr 13, 2021last inspection

OSHA has inspected Greg Weikle once in West Virginia.

The inspection began on Apr 13, 2021 after a complaint, in White Sulphur Springs.

That inspection ended with 9 citation items: 8 serious and 1 other-than-serious.

Penalties were first proposed at $19,895 and now stand at $12,000, 40% lower after settlements or reviews.

Scaffolds, general requirements comes up most often in these citations: 7 items under 1926.451.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Greg Weikle averages $12,000 (1 cited inspection).

Greg Weikle: OSHA citation items per year, 2021 to 2021
Citation items per year, by inspection date.

West Virginia · latest 90 days of OSHA records

28employers cited

Get notified the morning OSHA posts each new citation in West Virginia: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in West Virginia

Checking a subcontractor, a client or your own company? Watch Greg Weikle and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 345249205 OPENED APR 13, 2021Closed

Complaint · Partial · Safety · 6 employees at the site · Closed Aug 13, 2021

202 Walnut Place, White Sulphur Springs, WV 24986 · Residential Remodelers · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$4,096$2,500Jul 2, 2021Final
Citation 1, item 2
29 CFR 1926.451(b)(2) · Scaffolds, general requirements
Serious$4,096$2,500Jul 2, 2021Final
Citation 1, item 3
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$3,511$2,000Jul 2, 2021Final
Citation 1, item 4a
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$4,096$2,500Jul 2, 2021Final
Citation 1, item 4b
29 CFR 1926.451(g)(1)(v) · Scaffolds, general requirements
Serious$0$0Jul 2, 2021Final
Citation 1, item 4c
29 CFR 1926.451(b)(3) · Scaffolds, general requirements
Serious$0$0Jul 2, 2021Final
Citation 1, item 5a
29 CFR 1926.451(f)(7) · Scaffolds, general requirements
Serious$4,096$2,500Jul 2, 2021Final
Citation 1, item 5b
29 CFR 1926.454(a) · Scaffold training
Serious$0$0Jul 2, 2021Final
Citation 2, item 1
29 CFR 1926.452(c)(4) · Rules for each type of scaffold
Other-than-serious$0$0Jul 2, 2021Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(1)

(b) Scaffold platform construction. (1) Each platform on all working levels of scaffolds shall be fully planked or decked between the front uprights and the guardrail supports as follows:

29 CFR 1926.451(b)(2)

(2) Except as provided in paragraphs (b)(2)(i) and (b)(2)(ii) of this section, each scaffold platform and walkway shall be at least 18 inches (46 cm) wide.

29 CFR 1926.451(b)(3)

(3) Except as provided in paragraphs (b)(3) (i) and (ii) of this section, the front edge of all platforms shall not be more than 14 inches (36 cm) from the face of the work, unless guardrail systems are erected along the front edge and/or personal fall arrest systems are used in accordance with paragraph (g) of this section to protect employees from falling.

29 CFR 1926.452 · Rules for each type of scaffold

29 CFR 1926.454 · Scaffold training

Other residential remodelers employers in West Virginia

Alert subscribers get notified of each newly cited employer in West Virginia the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.