OSHA SearchOSHA records by employer

Grieger Enterprises, LLC: OSHA inspections and violations

Lakeland, Florida · General Warehousing and Storage · NAICS 493110

1inspections
4citation items
$13,826current penalties
Apr 24, 2024last inspection

OSHA inspectors have visited Grieger Enterprises, LLC in Florida one time.

It opened on Apr 24, 2024 after a complaint, in Lakeland.

In all, OSHA issued 4 citation items: 4 serious.

The penalties, $13,826 in total, stand where OSHA first set them.

The rule cited most here is 1910.303 (electrical equipment, general requirements), 3 times.

Among transportation and warehousing employers, the typical cited inspection since 2015 ends with a $3,555 penalty. Grieger Enterprises, LLC averages $13,826 across 1 cited inspection.

Grieger Enterprises, LLC: OSHA citation items per year, 2024 to 2024
Citation items per year, by inspection date.

Florida · latest 90 days of OSHA records

320employers cited

5 of them in the same industry

Get notified the morning OSHA posts each new citation in Florida: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Florida

Checking a subcontractor, a client or your own company? Watch Grieger Enterprises, LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347436370 OPENED APR 24, 2024Closed

Complaint · Partial · Safety · 24 employees at the site · Closed Jun 21, 2024

1820 N Crystal Lake Drive, Lakeland, FL 33801 · General Warehousing and Storage · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.178(l)(2)(ii) · Forklifts and other powered industrial trucks
Serious$5,531$5,531Jun 6, 2024Final
Citation 1, item 2
29 CFR 1910.303(f)(2) · Electrical equipment, general requirements
Serious$2,765$2,765Jun 6, 2024Final
Citation 1, item 3
29 CFR 1910.303(g)(1) · Electrical equipment, general requirements
Serious$2,765$2,765Jun 6, 2024Final
Citation 1, item 4
29 CFR 1910.303(g)(2)(i) · Electrical equipment, general requirements
Serious$2,765$2,765Jun 6, 2024Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.178(l)(2)(ii)

(ii) Training shall consist of a combination of formal instruction (e.g., lecture, discussion, interactive computer learning, video tape, written material), practical training (demonstrations performed by the trainer and practical exercises performed by the trainee), and evaluation of the operator's performance in the workplace.

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.303(f)(2)

(2) Services, feeders, and branch circuits. Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, shall be legibly marked to indicate its purpose, unless located and arranged so the purpose is evident.

29 CFR 1910.303(g)(1)

(1) Space about electric equipment. Sufficient access and working space shall be provided and maintained about all electric equipment to permit ready and safe operation and maintenance of such equipment.

Other general warehousing and storage employers in Florida

Alert subscribers get notified of each newly cited employer in Florida the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.