OSHA SearchOSHA records by employer

Guerrero Brick Mason, LLC: OSHA inspections and violations

Montgomery, Alabama · Masonry Contractors · NAICS 238140

2inspections
10citation items
$11,600current penalties
Oct 4, 2017last inspection

Guerrero Brick Mason, LLC has 2 OSHA inspections on record in Alabama, the first in 2015.

OSHA's last visit started on Oct 4, 2017 on a referral, in Pike Road.

Across those inspections OSHA issued 10 citation items: 10 serious.

OSHA proposed $16,209 in penalties. After settlements and reviews the total is $11,600, down 28%.

Most often, OSHA cited 1926.451, scaffolds, general requirements (9 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Guerrero Brick Mason, LLC averages $5,800 over 2 cited inspections in that time.

Guerrero Brick Mason, LLC: OSHA citation items per year, 2015 to 2017
Citation items per year, by inspection date.

Alabama · latest 90 days of OSHA records

95employers cited

3 of them in the same industry

Get notified the morning OSHA posts each new citation in Alabama: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Alabama

Checking a subcontractor, a client or your own company? Watch Guerrero Brick Mason, LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342698826 OPENED OCT 4, 2017Closed

Referral · Partial · Safety · 7 employees at the site · Closed Nov 19, 2018

Lot 16 Boykin Lakes Loop, Pike Road, AL 36064 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.100(a) · Hard hats in construction
Serious$1,630$800Dec 27, 2017Final
Citation 1, item 2
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$2,173$1,000Dec 27, 2017Final
Citation 1, item 3
29 CFR 1926.451(f)(3) · Scaffolds, general requirements
Serious$3,803$2,500Dec 27, 2017Final
Citation 1, item 4a
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$3,803$2,500Dec 27, 2017Final
Citation 1, item 4b
29 CFR 1926.451(b)(1)(i) · Scaffolds, general requirements
Serious$0$0Dec 27, 2017Final
Citation 1, item 4c
29 CFR 1926.451(b)(5)(ii) · Scaffolds, general requirements
Serious$0$0Dec 27, 2017Final

Inspection 340659713 OPENED JUN 4, 2015Closed

Planned · Partial · Safety · 6 employees at the site · Closed Oct 24, 2016

330 Melison Road Lot 19, Montgomery, AL 36101 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$1,600$1,600Aug 25, 2015Final
Citation 1, item 1b
29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements
Serious$0$0Aug 25, 2015Final
Citation 1, item 2
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$1,600$1,600Aug 25, 2015Final
Citation 1, item 3
29 CFR 1926.451(f)(3) · Scaffolds, general requirements
Serious$1,600$1,600Aug 25, 2015Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.100 · Hard hats in construction

29 CFR 1926.100(a)

(a) Employees working in areas where there is a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns, shall be protected by protective helmets.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(1)

(b) Scaffold platform construction. (1) Each platform on all working levels of scaffolds shall be fully planked or decked between the front uprights and the guardrail supports as follows:

29 CFR 1926.451(b)(1)(i)

(i) Each platform unit (e.g., scaffold plank, fabricated plank, fabricated deck, or fabricated platform) shall be installed so that the space between adjacent units and the space between the platform and the uprights is no more than 1 inch (2.5 cm) wide, except where the employer can demonstrate that a wider space is necessary (for example, to fit around uprights when side brackets are used to extend the width of the platform).

Other masonry contractors employers in Alabama

Alert subscribers get notified of each newly cited employer in Alabama the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.