OSHA SearchOSHA records by employer

H+S Remodeling Inc.: OSHA inspections and violations

Chicago, Illinois · New Single-Family Housing Construction (except For-Sale Builders) · NAICS 236115

2inspections
4citation items
$4,800current penalties
Mar 14, 2025last inspection

OSHA has inspected H+S Remodeling Inc. 2 times in Illinois since 2018.

The latest one began on Mar 14, 2025 as a planned inspection, in Evanston.

Those inspections ended with 4 citation items: 4 serious.

Penalties were first proposed at $12,565 and now stand at $4,800, 62% lower after settlements or reviews.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and H+S Remodeling Inc. averages $4,800 (1 cited inspection).

H+S Remodeling Inc.: OSHA citation items per year, 2018 to 2025
Citation items per year, by inspection date.

Illinois · latest 90 days of OSHA records

426employers cited

Get notified the morning OSHA posts each new citation in Illinois: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Illinois

Checking a subcontractor, a client or your own company? Watch H+S Remodeling Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 348109919 OPENED MAR 14, 2025Closed

Planned · Partial · Safety · 1 employee at the site · Closed Mar 27, 2025

1453 Maple Ave., Evanston, IL 60201 · New Single-Family Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 342983426 OPENED FEB 28, 2018Closed

Planned · Complete · Safety · 11 employees at the site · Closed Jun 5, 2018

1038 N. Ashland Ave., Chicago, IL 60622 · New Single-Family Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.150(c)(1)(i) · Fire protection
Serious$5,174$3,000Apr 4, 2018Final
Citation 1, item 1b
29 CFR 1926.154(b)(3) · Temporary heating devices
Serious$5,174$0Apr 4, 2018Final
Citation 1, item 3a
29 CFR 1926.403(b)(2) · Electrical equipment on job sites
Serious$2,217$1,800Apr 4, 2018Final
Citation 1, item 3b
29 CFR 1926.404(b)(1)(i) · Ground-fault protection on job sites
Serious$0$0Apr 4, 2018Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.150 · Fire protection

29 CFR 1926.150(c)(1)(i)

(c) Portable firefighting equipment—(1) Fire extinguishers and small hose lines. (i) A fire extinguisher, rated not less than 2A, shall be provided for each 3,000 square feet of the protected building area, or major fraction thereof. Travel distance from any point of the protected area to the nearest fire extinguisher shall not exceed 100 feet.

29 CFR 1926.154 · Temporary heating devices

29 CFR 1926.154(b)(3)

(3) Heaters not suitable for use on wood floors shall not be set directly upon them or other combustible materials. When such heaters are used, they shall rest on suitable heat insulating material or at least 1-inch concrete, or equivalent. The insulating material shall extend beyond the heater 2 feet or more in all directions.

29 CFR 1926.403 · Electrical equipment on job sites

29 CFR 1926.403(b)(2)

(2) Installation and use. Listed, labeled, or certified equipment shall be installed and used in accordance with instructions included in the listing, labeling, or certification.

29 CFR 1926.404 · Ground-fault protection on job sites

Other new single-family housing construction (except for-sale builders) employers in Illinois

Alert subscribers get notified of each newly cited employer in Illinois the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.