Hammer Contractors Advisors Corp.: OSHA inspections and violations

Anasco, Puerto Rico · Commercial and Institutional Building Construction · NAICS 236220

1inspections
11citation items
$4,700current penalties
Jul 25, 2017last inspection

OSHA inspectors have visited Hammer Contractors Advisors Corp. in Puerto Rico one time.

It opened on Jul 25, 2017 as a planned inspection, in Anasco.

In all, OSHA issued 11 citation items: 10 serious and 1 other-than-serious.

The penalties, $4,700 in total, stand where OSHA first set them.

The rule cited most here is 1926.451 (scaffolds, general requirements), 7 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Hammer Contractors Advisors Corp. averages $4,700 across 1 cited inspection.

Hammer Contractors Advisors Corp.: OSHA citation items per year, 2017 to 2017
Citation items per year, by inspection date.

Puerto Rico · latest 90 days of OSHA records

112employers cited

8 of them in the same industry

Get notified the morning OSHA posts each new citation in Puerto Rico: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Puerto Rico

Checking a subcontractor, a client or your own company? Watch Hammer Contractors Advisors Corp. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342508124 OPENED JUL 25, 2017Closed

Planned · Complete · Safety · 7 employees at the site · Closed Aug 14, 2018

Carr.#2 Int.carr. 110 Km 141, Bo. Quebrada Larga, Anasco, PR 00610 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.100(a) · Hard hats in construction
Serious$450$450Oct 26, 2017Final
Citation 1, item 1b
29 CFR 1926.451(h)(1) · Scaffolds, general requirements
Serious$0$0Oct 26, 2017Final
Citation 1, item 2
29 CFR 1926.404(b)(1)(ii) · Ground-fault protection on job sites
Serious$750$750Oct 26, 2017Final
Citation 1, item 3a
29 CFR 1926.451(c)(2) · Scaffolds, general requirements
Serious$1,400$1,400Oct 26, 2017Final
Citation 1, item 3b
29 CFR 1926.451(c)(2)(ii) · Scaffolds, general requirements
Serious$0$0Oct 26, 2017Final
Citation 1, item 4a
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$1,050$1,050Oct 26, 2017Final
Citation 1, item 4b
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$0$0Oct 26, 2017Final
Citation 1, item 4c
29 CFR 1926.451(g)(1)(v) · Scaffolds, general requirements
Serious$0$0Oct 26, 2017Final
Citation 1, item 5a
29 CFR 1926.451(f)(3) · Scaffolds, general requirements
Serious$1,050$1,050Oct 26, 2017Final
Citation 1, item 5b
29 CFR 1926.454(a) · Scaffold training
Serious$0$0Oct 26, 2017Final
Citation 2, item 1
29 CFR 1926.25(a) · Housekeeping
Other-than-serious$0$0Oct 26, 2017Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.100 · Hard hats in construction

29 CFR 1926.100(a)

(a) Employees working in areas where there is a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns, shall be protected by protective helmets.

29 CFR 1926.25 · Housekeeping

29 CFR 1926.25(a)

(a) During the course of construction, alteration, or repairs, form and scrap lumber with protruding nails, and all other debris, shall be kept cleared from work areas, passageways, and stairs, in and around buildings or other structures.

29 CFR 1926.404 · Ground-fault protection on job sites

29 CFR 1926.404(b)(1)(ii)

(ii) Ground-fault circuit interrupters. All 120-volt, single-phase, 15- and 20-ampere receptacle outlets on construction sites, which are not a part of the permanent wiring of the building or structure and which are in use by employees, shall have approved ground-fault circuit interrupters for personnel protection. Receptacles on a two-wire, single-phase portable or vehicle-mounted generator rated not more than 5kW, where the circuit conductors of the generator are insulated from the generator frame and all other grounded surfaces, need not be protected with ground-fault circuit interrupters.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.454 · Scaffold training

Other commercial and institutional building construction employers in Puerto Rico

Alert subscribers get notified of each newly cited employer in Puerto Rico the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.