OSHA SearchOSHA records by employer

Hammer's Underground Utility's Corp: OSHA inspections and violations

Columbia, Maryland · Electric Bulk Power Transmission and Control · NAICS 221121

2inspections
2citation items
$1,260current penalties
Dec 13, 2018last inspection

OSHA has inspected Hammer's Underground Utility's Corp 2 times in Maryland since 2016.

The latest one began on Dec 13, 2018 as a planned inspection, in Glen Burnie.

Those inspections ended with 2 citation items: 2 serious.

Penalties were first proposed at $2,100 and now stand at $1,260, 40% lower after settlements or reviews.

Excavations comes up most often in these citations: 2 items under 1926.651.

How that compares: the median penalty per cited inspection for utility employers since 2015 is $0, and Hammer's Underground Utility's Corp averages $1,260 (1 cited inspection).

Hammer's Underground Utility's Corp: OSHA citation items per year, 2016 to 2018
Citation items per year, by inspection date.

Maryland · latest 90 days of OSHA records

194employers cited

Get notified the morning OSHA posts each new citation in Maryland: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Maryland

Checking a subcontractor, a client or your own company? Watch Hammer's Underground Utility's Corp and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343660510 OPENED DEC 13, 2018Closed

Planned · Complete · Safety · 7 employees at the site · Closed Apr 4, 2019

200 Blk Holsum Way, Glen Burnie, MD 21060 · Power and Communication Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.651(c)(2) · Excavations
Serious$2,100$1,260Feb 14, 2019Final
Citation 1, item 1b
29 CFR 1926.651(k)(1) · Excavations
Serious$0$0Feb 14, 2019Final

Inspection 341491843 OPENED MAY 20, 2016Closed

Accident · Partial · Safety · 4 employees at the site · Closed Jun 21, 2016

6041 Majors Lane, Columbia, MD 21045 · Electric Bulk Power Transmission and Control · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.651 · Excavations

29 CFR 1926.651(c)(2)

(2) Means of egress from trench excavations. A stairway, ladder, ramp or other safe means of egress shall be located in trench excavations that are 4 feet (1.22 m) or more in depth so as to require no more than 25 feet (7.62 m) of lateral travel for employees.

29 CFR 1926.651(k)(1)

(k) Inspections. (1) Daily inspections of excavations, the adjacent areas, and protective systems shall be made by a competent person for evidence of a situation that could result in possible cave-ins, indications of failure of protective systems, hazardous atmospheres, or other hazardous conditions. An inspection shall be conducted by the competent person prior to the start of work and as needed throughout the shift. Inspections shall also be made after every rainstorm or other hazard increasing occurrence. These inspections are only required when employee exposure can be reasonably anticipated.

Other electric bulk power transmission and control employers in Maryland

Alert subscribers get notified of each newly cited employer in Maryland the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.