OSHA SearchOSHA records by employer

Hampton Roads Wood Renewal, LLC: OSHA inspections and violations

Portsmouth, Virginia · All Other Specialty Trade Contractors · NAICS 238990

2inspections
29citation items
$20,005current penalties
Jul 16, 2024last inspection

Hampton Roads Wood Renewal, LLC has 2 OSHA inspections on record in Virginia, the first in 2021.

OSHA's last visit started on Jul 16, 2024 after a complaint, in Portsmouth, and the case has not closed yet.

Across those inspections OSHA issued 29 citation items: 20 serious, 6 repeat and 3 other-than-serious.

OSHA proposed $20,005 in penalties and the amount has not been reduced.

Most often, OSHA cited 1910.134, respiratory protection (9 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Hampton Roads Wood Renewal, LLC averages $10,002 over 2 cited inspections in that time.

Hampton Roads Wood Renewal, LLC: OSHA citation items per year, 2021 to 2024
Citation items per year, by inspection date.

Virginia · latest 90 days of OSHA records

253employers cited

3 of them in the same industry

Get notified the morning OSHA posts each new citation in Virginia: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Virginia

Checking a subcontractor, a client or your own company? Watch Hampton Roads Wood Renewal, LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347625659 OPENED JUL 16, 2024Open

Complaint · Partial · Health · 4 employees at the site · Open

3901 Garwood Avenue Suite 2, Portsmouth, VA 23701 · Finish Carpentry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.134(c)(1) · Respiratory protection
Repeat$4,085$4,085Jan 3, 2025Contested
Citation 1, item 1b
29 CFR 1910.134(e)(1) · Respiratory protection
Repeat$0$0Jan 3, 2025Final
Citation 1, item 1c
29 CFR 1910.134(f)(2) · Respiratory protection
Repeat$0$0Jan 3, 2025Final
Citation 1, item 2a
29 CFR 1910.1200(e)(1) · Hazard communication
Repeat$5,940$5,940Jan 3, 2025Contested
Citation 1, item 2b
29 CFR 1910.1200(e)(1)(i) · Hazard communication
Repeat$0$0Jan 3, 2025Final
Citation 1, item 2c
29 CFR 1910.1200(g)(8) · Hazard communication
Repeat$0$0Jan 3, 2025Final
Citation 2, item 1a
29 CFR 1910.303(b)(2) · Electrical equipment, general requirements
Serious$1,980$1,980Jan 3, 2025Contested
Citation 2, item 1b
29 CFR 1910.305(g)(1)(iv)(a) · Electrical wiring methods
Serious$0$0Jan 3, 2025Final
Citation 2, item 2
29 CFR 1910.1200(h)(1) · Hazard communication
Serious$1,980$1,980Jan 3, 2025Contested
Citation 3, item 1 Other-than-serious$0$0Jan 3, 2025Final
Citation 3, item 2
29 CFR 1910.132(d)(2) · Personal protective equipment, general requirements
Other-than-serious$0$0Jan 3, 2025Final
Citation 3, item 3
29 CFR 1910.134(k)(1) · Respiratory protection
Other-than-serious$0$0Jan 3, 2025Final

Inspection 345418800 OPENED JUL 14, 2021Closed

Complaint · Complete · Health · 9 employees at the site · Closed Nov 3, 2023

3901 Garwood Avenue Suite 2, Portsmouth, VA 23701 · All Other Specialty Trade Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.22(a)(1) · Walking-working surfaces
Serious$1,285$1,285Oct 22, 2021Final
Citation 1, item 2a
29 CFR 1910.107(b)(1) · Spray painting and finishing
Serious$1,285$1,285Oct 22, 2021Final
Citation 1, item 2b
29 CFR 1910.107(b)(5)(i) · Spray painting and finishing
Serious$0$0Oct 22, 2021Final
Citation 1, item 2c
29 CFR 1910.107(c)(5) · Spray painting and finishing
Serious$0$0Oct 22, 2021Final
Citation 1, item 2d
29 CFR 1910.107(d)(7) · Spray painting and finishing
Serious$0$0Oct 22, 2021Final
Citation 1, item 2e
29 CFR 1910.107(f)(4) · Spray painting and finishing
Serious$0$0Oct 22, 2021Final
Citation 1, item 2f
29 CFR 1910.107(g)(2) · Spray painting and finishing
Serious$0$0Oct 22, 2021Final
Citation 1, item 2g
29 CFR 1910.107(g)(7) · Spray painting and finishing
Serious$0$0Oct 22, 2021Final
Citation 1, item 3a
29 CFR 1910.134(c)(1) · Respiratory protection
Serious$880$880Oct 22, 2021Final
Citation 1, item 3b
29 CFR 1910.134(e)(1) · Respiratory protection
Serious$0$0Oct 22, 2021Final
Citation 1, item 3c
29 CFR 1910.134(f)(2) · Respiratory protection
Serious$0$0Oct 22, 2021Final
Citation 1, item 3d
29 CFR 1910.134(g)(1)(i)(a) · Respiratory protection
Serious$0$0Oct 22, 2021Final
Citation 1, item 3e
29 CFR 1910.134(h)(2) · Respiratory protection
Serious$0$0Oct 22, 2021Final
Citation 1, item 4
29 CFR 1910.151(c) · First aid and eyewash
Serious$1,285$1,285Oct 22, 2021Final
Citation 1, item 5a
29 CFR 1910.1200(e)(1) · Hazard communication
Serious$1,285$1,285Oct 22, 2021Final
Citation 1, item 5b
29 CFR 1910.1200(e)(1)(i) · Hazard communication
Serious$0$0Oct 22, 2021Final
Citation 1, item 5c
29 CFR 1910.1200(g)(8) · Hazard communication
Serious$0$0Oct 22, 2021Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.107 · Spray painting and finishing

29 CFR 1910.107(b)(1)

(b) Spray booths—(1) Construction. Spray booths shall be substantially constructed of steel, securely and rigidly supported, or of concrete or masonry except that aluminum or other substantial noncombustible material may be used for intermittent or low volume spraying. Spray booths shall be designed to sweep air currents toward the exhaust outlet.

29 CFR 1910.107(b)(5)(i)

(i) The spraying operations except electrostatic spraying operations shall be so designed, installed and maintained that the average air velocity over the open face of the booth (or booth cross section during spraying operations) shall be not less than 100 linear feet per minute. Electrostatic spraying operations may be conducted with an air velocity over the open face of the booth of not less than 60 linear feet per minute, or more, depending on the volume of the finishing material being applied and its flammability and explosion characteristics. Visible gauges or audible alarm or pressure activated devices shall be installed to indicate or insure that the required air velocity is maintained. Filter rolls shall be inspected to insure proper replacement of filter media.

29 CFR 1910.107(c)(5)

(5) Combustible residues, areas. Unless specifically approved for locations containing both deposits of readily ignitable residue and explosive vapors, there shall be no electrical equipment in any spraying area, whereon deposits of combustible residues may readily accumulate, except wiring in rigid conduit or in boxes or fittings containing no taps, splices, or terminal connections.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.132 · Personal protective equipment, general requirements

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.151 · First aid and eyewash

29 CFR 1910.22 · Walking-working surfaces

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.94 · Ventilation

Other all other specialty trade contractors employers in Virginia

Alert subscribers get notified of each newly cited employer in Virginia the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.