OSHA SearchOSHA records by employer

Harrington's in Vermont, Inc.: OSHA inspections and violations

Richmond, Vermont · Meat Markets · NAICS 445210

5inspections
13citation items
$1,600current penalties
Dec 9, 2016last inspection

Harrington's in Vermont, Inc. has 5 OSHA inspections on record in Vermont, the first in 1985.

OSHA's last visit started on Dec 9, 2016 on a referral, in Richmond.

Across those inspections OSHA issued 13 citation items: 3 serious and 10 other-than-serious.

OSHA proposed $4,740 in penalties. After settlements and reviews the total is $1,600, down 66%.

Most often, OSHA cited 1910.157, portable fire extinguishers (3 items).

For context, across all retail employers the median penalty per cited inspection since 2015 is $1,750. Harrington's in Vermont, Inc. averages $1,000 over 1 cited inspection in that time.

Harrington's in Vermont, Inc.: OSHA citation items per year, 1985 to 2016
Citation items per year, by inspection date.

Vermont · latest 90 days of OSHA records

27employers cited

Get notified the morning OSHA posts each new citation in Vermont: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Vermont

Checking a subcontractor, a client or your own company? Watch Harrington's in Vermont, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 341981090 OPENED DEC 9, 2016Closed

Referral · Partial · Health · 130 employees at the site · Closed Mar 27, 2017

210 East Main Street, Richmond, VT 05477 · Meat Markets · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.151(c) · First aid and eyewash
Other-than-serious$3,240$1,000Mar 10, 2017Final
Citation 2, item 1
29 CFR 1910.1200(e)(1)(i) · Hazard communication
Other-than-serious$0$0Mar 10, 2017Final

Inspection 303453591 OPENED JUL 13, 2001Closed

Planned · Complete · Health · 100 employees at the site · Closed Oct 10, 2001

618 Main Street, Richmond, VT 05477 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.157(e)(2) · Portable fire extinguishers
Other-than-serious$0$0Sep 28, 2001Closed

Inspection 301490777 OPENED JAN 26, 1998Closed

Planned · Complete · Safety · 35 employees at the site · Closed Mar 5, 1998

618 Main Street, Richmond, VT 05477 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.151(c) · First aid and eyewash
Serious$375$200Feb 11, 1998Closed
Citation 1, item 2
29 CFR 1910.157(e)(2) · Portable fire extinguishers
Other-than-serious$375$0Feb 11, 1998Closed
Citation 1, item 3
29 CFR 1910.212(a)(1) · Machine guarding
Serious$375$200Feb 11, 1998Closed
Citation 1, item 4
29 CFR 1910.303(b)(1) · Electrical equipment, general requirements
Serious$375$200Feb 11, 1998Closed

Inspection 111727723 OPENED JAN 25, 1991Closed

Complaint · Partial · Safety · 15 employees at the site · Closed Mar 18, 1991

618 Main Street, Richmond, VT 05477 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.219(c)(2)(i) · Belts, pulleys and power-transmission parts
Other-than-serious$0$0Feb 11, 1991Closed
Citation 1, item 2
29 CFR 1910.219(i)(2) · Belts, pulleys and power-transmission parts
Other-than-serious$0$0Feb 11, 1991Closed

Inspection 3288982 OPENED JUN 13, 1985Closed

Planned · Complete · Safety · 35 employees at the site · Closed Aug 12, 1985

618 Main St, Richmond, VT 05477 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.157(g)(1) · Portable fire extinguishers
Other-than-serious$0$0Jun 21, 1985Closed
Citation 1, item 2
29 CFR 1910.178(g)(10) · Forklifts and other powered industrial trucks
Other-than-serious$0$0Jun 21, 1985Closed
Citation 1, item 3
29 CFR 1910.304(f)(5)(v) · Grounding and circuit protection
Other-than-serious$0$0Jun 21, 1985Closed
Citation 1, item 4
29 CFR 1910.305(b)(1) · Electrical wiring methods
Other-than-serious$0$0Jun 21, 1985Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(e)(1)(i)

(i) A list of the hazardous chemicals known to be present using a product identifier that is referenced on the appropriate safety data sheet (the list may be compiled for the workplace as a whole or for individual work areas); and,

29 CFR 1910.151 · First aid and eyewash

29 CFR 1910.151(c)

(c) Where the eyes or body of any person may be exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body shall be provided within the work area for immediate emergency use.

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.157(e)(2)

(2) Portable extinguishers or hose used in lieu thereof under paragraph (d)(3) of this section shall be visually inspected monthly.

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.212 · Machine guarding

29 CFR 1910.219 · Belts, pulleys and power-transmission parts

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.304 · Grounding and circuit protection

29 CFR 1910.305 · Electrical wiring methods

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.