OSHA SearchOSHA records by employer

Harris Handyman Service: OSHA inspections and violations

Columbus, Ohio · Water and Sewer Line and Related Structures Construction · NAICS 237110

2inspections
8citation items
$15,676current penalties
Oct 18, 2021last inspection

OSHA has inspected Harris Handyman Service 2 times in Ohio since 2016.

The latest one began on Oct 18, 2021 as a planned inspection, in Columbus.

Those inspections ended with 8 citation items: 8 serious.

Penalties were first proposed at $31,352 and now stand at $15,676, 50% lower after settlements or reviews.

Excavations comes up most often in these citations: 5 items under 1926.651.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Harris Handyman Service averages $7,838 (2 cited inspections).

Harris Handyman Service: OSHA citation items per year, 2016 to 2021
Citation items per year, by inspection date.

Ohio · latest 90 days of OSHA records

260employers cited

5 of them in the same industry

Get notified the morning OSHA posts each new citation in Ohio: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Ohio

Checking a subcontractor, a client or your own company? Watch Harris Handyman Service and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 345585582 OPENED OCT 18, 2021Closed

Planned · Partial · Safety · 4 employees at the site · Closed Dec 5, 2022

2010 And 2018 Tuppsfield Road, Columbus, OH 43229 · Water and Sewer Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.651(i)(1) · Excavations
Serious$4,096$2,048Nov 1, 2021Final
Citation 1, item 2
29 CFR 1926.651(j)(2) · Excavations
Serious$4,096$2,048Nov 1, 2021Final
Citation 1, item 3
29 CFR 1926.651(k)(1) · Excavations
Serious$4,096$2,048Nov 1, 2021Final
Citation 1, item 4
29 CFR 1926.652(a)(1) · Trench protection
Serious$4,096$2,048Nov 1, 2021Final

Inspection 341600211 OPENED JUL 6, 2016Closed

Planned · Partial · Safety · 4 employees at the site · Closed Sep 25, 2017

1200 East 19th Avenue, Columbus, OH 43214 · Water and Sewer Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.651(j)(2) · Excavations
Serious$3,742$1,871Aug 11, 2016Final
Citation 1, item 2
29 CFR 1926.651(k)(1) · Excavations
Serious$3,742$1,871Aug 11, 2016Final
Citation 1, item 3
29 CFR 1926.652(a)(1) · Trench protection
Serious$3,742$1,871Aug 11, 2016Final
Citation 1, item 4
29 CFR 1926.652(g)(1)(ii) · Trench protection
Serious$3,742$1,871Aug 11, 2016Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.651 · Excavations

29 CFR 1926.651(i)(1)

(i) Stability of adjacent structures. (1) Where the stability of adjoining buildings, walls, or other structures is endangered by excavation operations, support systems such as shoring, bracing, or underpinning shall be provided to ensure the stability of such structures for the protection of employees.

29 CFR 1926.651(j)(2)

(2) Employees shall be protected from excavated or other materials or equipment that could pose a hazard by falling or rolling into excavations. Protection shall be provided by placing and keeping such materials or equipment at least 2 feet (.61 m) from the edge of excavations, or by the use of retaining devices that are sufficient to prevent materials or equipment from falling or rolling into excavations, or by a combination of both if necessary.

29 CFR 1926.651(k)(1)

(k) Inspections. (1) Daily inspections of excavations, the adjacent areas, and protective systems shall be made by a competent person for evidence of a situation that could result in possible cave-ins, indications of failure of protective systems, hazardous atmospheres, or other hazardous conditions. An inspection shall be conducted by the competent person prior to the start of work and as needed throughout the shift. Inspections shall also be made after every rainstorm or other hazard increasing occurrence. These inspections are only required when employee exposure can be reasonably anticipated.

29 CFR 1926.652 · Trench protection

Other water and sewer line and related structures construction employers in Ohio

Alert subscribers get notified of each newly cited employer in Ohio the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.