OSHA SearchOSHA records by employer

Shinn Bros., Inc.: OSHA inspections and violations

Gettysburg, Ohio · Water and Sewer Line and Related Structures Construction · NAICS 237110

4inspections
8citation items
$17,321current penalties
Jul 28, 2026last inspection

OSHA has inspected Shinn Bros., Inc. 4 times in Ohio since 2008.

The latest one began on Jul 28, 2026 on a referral, in Celina.

Those inspections ended with 8 citation items: 8 serious.

Penalties were first proposed at $22,012 and now stand at $17,321, 21% lower after settlements or reviews.

Excavations comes up most often in these citations: 4 items under 1926.651.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Shinn Bros., Inc. averages $7,086 (2 cited inspections).

Shinn Bros., Inc.: OSHA citation items per year, 2008 to 2026
Citation items per year, by inspection date.

Ohio · latest 90 days of OSHA records

263employers cited

5 of them in the same industry

Get notified the morning OSHA posts each new citation in Ohio: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Ohio

Checking a subcontractor, a client or your own company? Watch Shinn Bros., Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 349078626 OPENED JUL 28, 2026Closed

Referral · Partial · Safety · 4 employees at the site · Closed Nov 10, 2026

2118 E. Market St., Celina, OH 45822 · Water and Sewer Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.651(c)(2) · Excavations
Serious$4,965$4,965Oct 15, 2026Final
Citation 1, item 2a
29 CFR 1926.651(k)(1) · Excavations
Serious$4,965$4,965Oct 15, 2026Final
Citation 1, item 2b
29 CFR 1926.652(a)(1) · Trench protection
Serious$0$0Oct 15, 2026Final

Inspection 344721691 OPENED APR 9, 2020Closed

Complaint · Partial · Safety · 17 employees at the site · Closed Jun 17, 2020

284 Railroad Street, Fort Recovery, OH 45846 · Water and Sewer Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.651(c)(2) · Excavations
Serious$3,084$1,542May 7, 2020Final
Citation 1, item 2
29 CFR 1926.652(a)(1) · Trench protection
Serious$5,398$2,699May 7, 2020Final

Inspection 330975897 OPENED AUG 15, 2011Closed

Planned · Partial · Safety · 20 employees at the site · Closed Aug 17, 2011

125 West Main St., Osgood, OH 45351 · Water and Sewer Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 311912976 OPENED APR 16, 2008Closed

Planned · Partial · Safety · 20 employees at the site · Closed May 27, 2008

High St And St Johns St, Gettysburg, OH 45328 · Site Preparation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.20(b)(2) · Construction safety programs
Serious$1,500$1,050May 1, 2008Closed
Citation 1, item 2
29 CFR 1926.651(c)(2) · Excavations
Serious$1,050$1,050May 1, 2008Closed
Citation 1, item 3
29 CFR 1926.652(a)(1) · Trench protection
Serious$1,050$1,050May 1, 2008Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.20 · Construction safety programs

29 CFR 1926.20(b)(2)

(2) Such programs shall provide for frequent and regular inspections of the job sites, materials, and equipment to be made by competent persons designated by the employers.

29 CFR 1926.651 · Excavations

29 CFR 1926.651(c)(2)

(2) Means of egress from trench excavations. A stairway, ladder, ramp or other safe means of egress shall be located in trench excavations that are 4 feet (1.22 m) or more in depth so as to require no more than 25 feet (7.62 m) of lateral travel for employees.

29 CFR 1926.651(k)(1)

(k) Inspections. (1) Daily inspections of excavations, the adjacent areas, and protective systems shall be made by a competent person for evidence of a situation that could result in possible cave-ins, indications of failure of protective systems, hazardous atmospheres, or other hazardous conditions. An inspection shall be conducted by the competent person prior to the start of work and as needed throughout the shift. Inspections shall also be made after every rainstorm or other hazard increasing occurrence. These inspections are only required when employee exposure can be reasonably anticipated.

29 CFR 1926.652 · Trench protection

Other water and sewer line and related structures construction employers in Ohio

Alert subscribers get notified of each newly cited employer in Ohio the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.