Header Construction, Inc: OSHA inspections and violations

Horseheads, New York · Framing Contractors · NAICS 238130

3inspections
41citation items
$24,169current penalties
Feb 24, 2020last inspection

OSHA has inspected Header Construction, Inc 3 times in New York since 2012.

The latest one began on Feb 24, 2020, in Middletown.

Those inspections ended with 41 citation items: 39 serious and 2 repeat.

Penalties were first proposed at $97,692 and now stand at $24,169, 75% lower after settlements or reviews.

Fall protection in construction comes up most often in these citations: 6 items under 1926.501.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,079, and Header Construction, Inc averages $2,169 (1 cited inspection).

Header Construction, Inc: OSHA citation items per year, 2012 to 2020
Citation items per year, by inspection date.

Want to know if OSHA cites Header Construction, Inc again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 344655931 OPENED FEB 24, 2020Closed

Unprogrammed other · Partial · Safety · 4 employees at the site · Closed Apr 30, 2020

6 Inwood Drive, Middletown, NY 10941 · Framing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$2,892$2,169Apr 3, 2020Final

Inspection 336417787 OPENED SEP 6, 2012Closed

Planned · Complete · Safety · 20 employees at the site · Closed Nov 13, 2015

Fairfield Inn - Parcel 7 I-86 & Ann Page Rd, Horseheads, NY 14845 · Framing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.34(b) · Means of egress
Serious$1,760$315Mar 1, 2013Final
Citation 1, item 2
29 CFR 1926.51(a) · Sanitation
Serious$1,320$235Mar 1, 2013Final
Citation 1, item 3
29 CFR 1910.178(l)(4)(iii) · Forklifts and other powered industrial trucks
Serious$1,320$235Mar 1, 2013Final
Citation 1, item 4
29 CFR 1926.251(a)(2)(ii) · Rigging equipment for material handling
Serious$2,200$395Mar 1, 2013Final
Citation 1, item 5
29 CFR 1926.251(b)(3) · Rigging equipment for material handling
Serious$2,200$395Mar 1, 2013Final
Citation 1, item 6
29 CFR 1926.251(c)(5) · Rigging equipment for material handling
Serious$2,200$395Mar 1, 2013Final
Citation 1, item 7a
29 CFR 1926.451(a)(6) · Scaffolds, general requirements
Serious$1,760$315Mar 1, 2013Final
Citation 1, item 7b
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$0$0Mar 1, 2013Final
Citation 1, item 8
29 CFR 1926.451(f)(3) · Scaffolds, general requirements
Serious$1,320$235Mar 1, 2013Final
Citation 1, item 9a
29 CFR 1926.454(a) · Scaffold training
Serious$1,760$315Mar 1, 2013Final
Citation 1, item 9b
29 CFR 1926.454(b) · Scaffold training
Serious$0$0Mar 1, 2013Final
Citation 1, item 9c
29 CFR 1926.454(c) · Scaffold training
Serious$0$0Mar 1, 2013Final
Citation 1, item 10
29 CFR 1926.501(a)(2) · Fall protection in construction
Serious$2,200$395Mar 1, 2013Final
Citation 1, item 11
29 CFR 1926.501(b)(2) · Fall protection in construction
Serious$2,200$395Mar 1, 2013Final
Citation 1, item 12
29 CFR 1926.501(b)(3) · Fall protection in construction
Serious$2,200$395Mar 1, 2013Final
Citation 1, item 13
29 CFR 1926.503(a)(1) · Fall protection training in construction
Serious$2,200$395Mar 1, 2013Final
Citation 1, item 14a
29 CFR 1926.602(c)(1)(i) · Earthmovers and forklifts in construction
Serious$1,320$235Feb 28, 2013Final
Citation 1, item 14b
29 CFR 1926.602(c)(1)(ii) · Earthmovers and forklifts in construction
Serious$0$0Mar 1, 2013Final
Citation 1, item 14c
29 CFR 1926.602(c)(1)(vi) · Earthmovers and forklifts in construction
Serious$0$0Mar 1, 2013Final
Citation 1, item 15
29 CFR 1926.1051(a) · Stairways and Ladders: general requirements
Serious$2,200$395Mar 1, 2013Final
Citation 1, item 16
29 CFR 1926.1053(b)(1) · Ladders in construction
Serious$1,760$315Mar 1, 2013Final
Citation 1, item 17
29 CFR 1926.1053(b)(13) · Ladders in construction
Serious$3,080$550Mar 1, 2013Final
Citation 1, item 18
29 CFR 1926.1053(b)(16) · Ladders in construction
Serious$2,200$395Mar 1, 2013Final
Citation 1, item 19
29 CFR 1926.1060(a)(1) · Ladder and stairway training
Serious$1,320$235Mar 1, 2013Final
Citation 1, item 20a
29 CFR 1926.1412(d)(1) · Inspections
Serious$1,320$235Mar 1, 2013Final
Citation 1, item 20b
29 CFR 1926.1413(a)(1) · Wire rope—inspection
Serious$0$0Mar 1, 2013Final
Citation 1, item 21
29 CFR 1926.1416(d)(3)(i) · Operational aids
Serious$3,080$550Mar 1, 2013Final
Citation 1, item 22a Serious$3,080$550Mar 1, 2013Final
Citation 1, item 22b Serious$0$0Mar 1, 2013Final
Citation 1, item 23 Serious$2,200$395Mar 1, 2013Final
Citation 1, item 24
29 CFR 1926.1425(c)(3) · Keeping clear of the load
Serious$2,200$395Mar 1, 2013Final
Citation 2, item 1
29 CFR 1926.501(b)(1) · Fall protection in construction
Repeat$30,800$5,545Mar 1, 2013Final
Citation 3, item 2
29 CFR 1926.34(a) · Means of egress
Repeat$4,400$790Mar 1, 2013Final

Inspection 334498144 OPENED MAY 25, 2012Closed

Planned · Partial · Safety · 4 employees at the site · Closed Jun 3, 2015

1070 Sing Sing Road, Horseheads, NY 14845 · Framing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.178(a)(4) · Forklifts and other powered industrial trucks
Serious$2,000$3,000Jul 5, 2012Final
Citation 1, item 1b
29 CFR 1910.178(l)(1)(i) · Forklifts and other powered industrial trucks
Serious$1,200$0Jul 5, 2012Final
Citation 1, item 1c
29 CFR 1910.178(m)(5)(i) · Forklifts and other powered industrial trucks
Serious$2,000$0Jul 5, 2012Final
Citation 1, item 1d
29 CFR 1910.178(m)(5)(iii) · Forklifts and other powered industrial trucks
Serious$0$0Jul 5, 2012Final
Citation 1, item 1e
29 CFR 1910.178(o)(2) · Forklifts and other powered industrial trucks
Serious$2,000$0Jul 5, 2012Final
Citation 1, item 5
29 CFR 1926.34(a) · Means of egress
Serious$2,000$2,000Jul 5, 2012Final
Citation 1, item 6
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$2,000$2,000Jul 5, 2012Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.178(a)(4)

(4) Modifications and additions which affect capacity and safe operation shall not be performed by the customer or user without manufacturers prior written approval. Capacity, operation, and maintenance instruction plates, tags, or decals shall be changed accordingly.

29 CFR 1910.178(l)(1)(i)

(l) Operator training. (1) Safe operation. (i) The employer shall ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l).

29 CFR 1910.178(l)(4)(iii)

(iii) An evaluation of each powered industrial truck operator's performance shall be conducted at least once every three years.

29 CFR 1926.1051 · Stairways and Ladders: general requirements

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1060 · Ladder and stairway training

29 CFR 1926.1412 · Inspections

29 CFR 1926.1413 · Wire rope—inspection

29 CFR 1926.1416 · Operational aids

29 CFR 1926.1417 · Operation

29 CFR 1926.1425 · Keeping clear of the load

29 CFR 1926.251 · Rigging equipment for material handling

29 CFR 1926.34 · Means of egress

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.454 · Scaffold training

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.503 · Fall protection training in construction

29 CFR 1926.51 · Sanitation

29 CFR 1926.602 · Earthmovers and forklifts in construction

Other framing contractors employers in New York

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.