OSHA SearchOSHA records by employer

Headwaiter, Inc.: OSHA inspections and violations

Phoenix, Arizona · Reupholstery and Furniture Repair · NAICS 811420

2inspections
17citation items
$2,550current penalties
Apr 28, 2015last inspection

Headwaiter, Inc. has 2 OSHA inspections on record in Arizona, the first in 2015.

OSHA's last visit started on Apr 28, 2015 after a complaint, in Phoenix.

Across those inspections OSHA issued 17 citation items: 8 serious and 9 other-than-serious.

OSHA proposed $3,000 in penalties. After settlements and reviews the total is $2,550, down 15%.

Most often, OSHA cited 1910.107, spray painting and finishing (5 items).

For context, across all repair and personal services employers the median penalty per cited inspection since 2015 is $1,200. Headwaiter, Inc. averages $1,275 over 2 cited inspections in that time.

Headwaiter, Inc.: OSHA citation items per year, 2015 to 2015
Citation items per year, by inspection date.

Arizona · latest 90 days of OSHA records

92employers cited

Get notified the morning OSHA posts each new citation in Arizona: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Arizona

Checking a subcontractor, a client or your own company? Watch Headwaiter, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 340589936 OPENED APR 28, 2015Closed

Complaint · Complete · Safety · 3 employees at the site · Closed Jan 17, 2017

2540 N 35th Ave Ste 16, Phoenix, AZ 85009 · Reupholstery and Furniture Repair · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.212(a)(1) · Machine guarding
Serious$750$638May 20, 2015Final
Citation 1, item 1b
29 CFR 1910.215(a)(2) · Grinders and abrasive wheels
Serious$0$0May 20, 2015Final
Citation 1, item 2
29 CFR 1910.213(d)(1) · Woodworking machinery
Serious$750$638May 20, 2015Final
Citation 2, item 1
29 CFR 1910.157(e)(2) · Portable fire extinguishers
Other-than-serious$0$0May 20, 2015Final
Citation 2, item 2
29 CFR 1910.157(e)(3) · Portable fire extinguishers
Other-than-serious$0$0May 20, 2015Final
Citation 2, item 3
29 CFR 1910.303(b)(2) · Electrical equipment, general requirements
Other-than-serious$0$0May 20, 2015Final

Inspection 340590140 OPENED APR 28, 2015Closed

Complaint · Complete · Health · 3 employees at the site · Closed Jan 13, 2017

2540 N 35th Ave #16, Phoenix, AZ 85009 · Reupholstery and Furniture Repair · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.107(b)(5)(i) · Spray painting and finishing
Serious$750$638May 26, 2015Final
Citation 1, item 1b
29 CFR 1910.107(d)(7) · Spray painting and finishing
Serious$0$0May 26, 2015Final
Citation 1, item 2a
29 CFR 1910.107(b)(9) · Spray painting and finishing
Serious$750$638May 26, 2015Final
Citation 1, item 2b
29 CFR 1910.107(f)(1) · Spray painting and finishing
Serious$0$0May 26, 2015Final
Citation 1, item 2c
29 CFR 1910.107(g)(7) · Spray painting and finishing
Serious$0$0May 26, 2015Final
Citation 2, item 1
29 CFR 1910.134(c)(1) · Respiratory protection
Other-than-serious$0$0May 26, 2015Final
Citation 2, item 2
29 CFR 1910.134(e)(1) · Respiratory protection
Other-than-serious$0$0May 26, 2015Final
Citation 2, item 3
29 CFR 1910.134(f)(1) · Respiratory protection
Other-than-serious$0$0May 26, 2015Final
Citation 2, item 4
29 CFR 1910.134(k)(1)(i) · Respiratory protection
Other-than-serious$0$0May 26, 2015Final
Citation 2, item 5
29 CFR 1910.1200(e)(1) · Hazard communication
Other-than-serious$0$0May 26, 2015Final
Citation 2, item 6
29 CFR 1910.1200(h)(3)(iv) · Hazard communication
Other-than-serious$0$0May 26, 2015Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.107 · Spray painting and finishing

29 CFR 1910.107(b)(5)(i)

(i) The spraying operations except electrostatic spraying operations shall be so designed, installed and maintained that the average air velocity over the open face of the booth (or booth cross section during spraying operations) shall be not less than 100 linear feet per minute. Electrostatic spraying operations may be conducted with an air velocity over the open face of the booth of not less than 60 linear feet per minute, or more, depending on the volume of the finishing material being applied and its flammability and explosion characteristics. Visible gauges or audible alarm or pressure activated devices shall be installed to indicate or insure that the required air velocity is maintained. Filter rolls shall be inspected to insure proper replacement of filter media.

29 CFR 1910.107(b)(9)

(9) Cleaning. Spray booths shall be so installed that all portions are readily accessible for cleaning. A clear space of not less than 3 feet on all sides shall be kept free from storage or combustible construction.

29 CFR 1910.107(d)(7)

(7) Exhaust ducts. Exhaust ducts shall be constructed of steel and shall be substantially supported. Exhaust ducts without dampers are preferred; however, if dampers are installed, they shall be maintained so that they will be in a full open position at all times the ventilating system is in operation.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.212 · Machine guarding

29 CFR 1910.213 · Woodworking machinery

29 CFR 1910.215 · Grinders and abrasive wheels

29 CFR 1910.303 · Electrical equipment, general requirements

Other reupholstery and furniture repair employers in Arizona

Alert subscribers get notified of each newly cited employer in Arizona the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.