OSHA SearchOSHA records by employer

Heimer Construction Company, Inc.: OSHA inspections and violations

Quincy, Illinois · Commercial and Institutional Building Construction · NAICS 236220

2inspections
18citation items
$8,650current penalties
Jan 26, 2015last inspection

OSHA has inspected Heimer Construction Company, Inc. 2 times in Illinois since 1994.

The latest one began on Jan 26, 2015 as a planned inspection, in Quincy.

Those inspections ended with 18 citation items: 16 serious and 2 other-than-serious.

Penalties were first proposed at $19,200 and now stand at $8,650, 55% lower after settlements or reviews.

Hazard communication comes up most often in these citations: 5 items under 1926.59.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Heimer Construction Company, Inc. averages $3,850 (1 cited inspection).

Heimer Construction Company, Inc.: OSHA citation items per year, 1994 to 2015
Citation items per year, by inspection date.

Illinois · latest 90 days of OSHA records

421employers cited

4 of them in the same industry

Get notified the morning OSHA posts each new citation in Illinois: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Illinois

Checking a subcontractor, a client or your own company? Watch Heimer Construction Company, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 340207646 OPENED JAN 26, 2015Closed

Planned · Partial · Safety · 7 employees at the site · Closed Mar 31, 2015

North 54th Street, Quincy, IL 62305 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 2
29 CFR 1926.453(b)(2)(v) · Aerial lifts
Serious$3,500$1,750Feb 20, 2015Final
Citation 1, item 4a
29 CFR 1926.1053(b)(4) · Ladders in construction
Serious$4,200$2,100Feb 20, 2015Final
Citation 1, item 4b
29 CFR 1926.20(b)(2) · Construction safety programs
Serious$3,500$0Feb 20, 2015Final

Inspection 122189897 OPENED JUN 2, 1994Closed

Planned · Complete · Safety · 10 employees at the site · Closed Dec 16, 1994

6th & Maine, Quincy, IL 62301 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.59(e)(1) · Hazard communication
Serious$750$450Jun 22, 1994Closed
Citation 1, item 1b
29 CFR 1926.59(f)(5)(i) · Hazard communication
Serious$0$0Jun 22, 1994Closed
Citation 1, item 1c
29 CFR 1926.59(f)(5)(ii) · Hazard communication
Serious$0$0Jun 22, 1994Closed
Citation 1, item 1d
29 CFR 1926.59(g)(1) · Hazard communication
Serious$0$0Jun 22, 1994Closed
Citation 1, item 1e
29 CFR 1926.59(h) · Hazard communication
Serious$0$0Jun 22, 1994Closed
Citation 1, item 2a
29 CFR 1926.95(a) · Criteria for personal protective equipment
Serious$1,250$750Jun 22, 1994Closed
Citation 1, item 2b
29 CFR 1926.602(c)(1)(vi) · Earthmovers and forklifts in construction
Serious$0$0Jun 22, 1994Closed
Citation 1, item 3a
29 CFR 1926.152(e)(2) · Flammable liquids
Serious$750$450Jun 22, 1994Closed
Citation 1, item 3b
29 CFR 1926.152(e)(3) · Flammable liquids
Serious$0$0Jun 22, 1994Closed
Citation 1, item 4
29 CFR 1926.451(a)(4) · Scaffolds, general requirements
Serious$1,750$1,050Jun 22, 1994Closed
Citation 1, item 5
29 CFR 1926.500(b)(1) · Scope, application, and definitions applicable to this subpart
Serious$1,000$600Jun 22, 1994Closed
Citation 1, item 6
29 CFR 1926.1052(c)(1) · Stairways in construction
Serious$1,000$600Jun 22, 1994Closed
Citation 1, item 7
29 CFR 1926.701(b) · Concrete and Masonry Construction: general requirements
Serious$1,000$600Jun 22, 1994Closed
Citation 2, item 1
29 CFR 1926.20(b)(2) · Construction safety programs
Other-than-serious$500$300Jun 22, 1994Closed
Citation 2, item 2
29 CFR 1926.152(a)(1) · Flammable liquids
Other-than-serious$0$0Jun 22, 1994Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1052 · Stairways in construction

29 CFR 1926.1052(c)(1)

(1) Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, shall be equipped with:

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(4)

(4) Ladders shall be used only for the purpose for which they were designed.

29 CFR 1926.152 · Flammable liquids

29 CFR 1926.152(a)(1)

(a) General requirements. (1) Only approved containers and portable tanks shall be used for storage and handling of flammable liquids. Approved safety cans or Department of Transportation approved containers shall be used for the handling and use of flammable liquids in quantities of 5 gallons or less, except that this shall not apply to those flammable liquid materials which are highly viscid (extremely hard to pour), which may be used and handled in original shipping containers. For quantities of one gallon or less, the original container may be used, for storage, use and handling of flammable liquids.

29 CFR 1926.20 · Construction safety programs

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.453 · Aerial lifts

29 CFR 1926.500 · Scope, application, and definitions applicable to this subpart

29 CFR 1926.59 · Hazard communication

29 CFR 1926.602 · Earthmovers and forklifts in construction

29 CFR 1926.701 · Concrete and Masonry Construction: general requirements

29 CFR 1926.95 · Criteria for personal protective equipment

Other commercial and institutional building construction employers in Illinois

Alert subscribers get notified of each newly cited employer in Illinois the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.