OSHA SearchOSHA records by employer

Heritage Motors, Inc.: OSHA inspections and violations

South Burlington, Vermont · Automotive Body, Paint, and Interior Repair and Maintenance · NAICS 811121

1inspections
7citation items
$5,000current penalties
Jun 23, 2017last inspection

Heritage Motors, Inc. has one OSHA inspection on record in Vermont.

OSHA opened it on Jun 23, 2017, in South Burlington.

From that inspection OSHA issued 7 citation items: 5 serious and 2 other-than-serious.

OSHA proposed $12,825 in penalties. After settlements and reviews the total is $5,000, down 61%.

Most often, OSHA cited 1910.107, spray painting and finishing (2 items).

For context, across all repair and personal services employers the median penalty per cited inspection since 2015 is $1,200. Heritage Motors, Inc. averages $5,000 over 1 cited inspection in that time.

Heritage Motors, Inc.: OSHA citation items per year, 2017 to 2017
Citation items per year, by inspection date.

Vermont · latest 90 days of OSHA records

27employers cited

Get notified the morning OSHA posts each new citation in Vermont: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Vermont

Checking a subcontractor, a client or your own company? Watch Heritage Motors, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342424470 OPENED JUN 23, 2017Closed

Unprogrammed other · Complete · Health · 138 employees at the site · Closed Nov 20, 2017

40 Green Mountain Drive, South Burlington, VT 05403 · Automotive Body, Paint, and Interior Repair and Maintenance · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.107(c)(6) · Spray painting and finishing
Serious$4,050$1,750Oct 25, 2017Final
Citation 1, item 1b
29 CFR 1910.107(m)(1) · Spray painting and finishing
Serious$0$0Oct 25, 2017Final
Citation 1, item 2
29 CFR 1910.132(d)(1) · Personal protective equipment, general requirements
Serious$4,050$1,750Oct 25, 2017Final
Citation 1, item 3
29 CFR 1910.141(g)(2) · Sanitation
Serious$2,025$750Oct 25, 2017Final
Citation 1, item 4
29 CFR 1910.304(b)(3)(ii)(c)(3) · Grounding and circuit protection
Serious$2,700$750Oct 25, 2017Final
Citation 2, item 1
29 CFR 1910.106(e)(6)(ii) · Flammable liquids
Other-than-serious$0$0Oct 25, 2017Final
Citation 2, item 2
29 CFR 1910.1200(f)(6)(ii) · Hazard communication
Other-than-serious$0$0Oct 25, 2017Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.106 · Flammable liquids

29 CFR 1910.106(e)(6)(ii)

(ii) Grounding. Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), shall not be dispensed into containers unless the nozzle and container are electrically interconnected. Where the metallic floorplate on which the container stands while filling is electrically connected to the fill stem or where the fill stem is bonded to the container during filling operations by means of a bond wire, the provisions of this section shall be deemed to have been complied with.

29 CFR 1910.107 · Spray painting and finishing

29 CFR 1910.107(c)(6)

(6) Wiring type approved. Electrical wiring and equipment not subject to deposits of combustible residues but located in a spraying area as herein defined shall be of explosion-proof type approved for Class I, group D locations and shall otherwise conform to the provisions of subpart S of this part, for Class I, Division 1, Hazardous Locations. Electrical wiring, motors, and other equipment outside of but within twenty (20) feet of any spraying area, and not separated therefrom by partitions, shall not produce sparks under normal operating conditions and shall otherwise conform to the provisions of subpart S of this part for Class I, Division 2 Hazardous Locations.

29 CFR 1910.107(m)(1)

(m) Organic peroxides and dual component coatings—(1) Conformance. All spraying operations involving the use of organic peroxides and other dual component coatings shall be conducted in approved sprinklered spray booths meeting the requirements of this section.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.132 · Personal protective equipment, general requirements

29 CFR 1910.141 · Sanitation

29 CFR 1910.304 · Grounding and circuit protection

Other automotive body, paint, and interior repair and maintenance employers in Vermont

Alert subscribers get notified of each newly cited employer in Vermont the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.