OSHA SearchOSHA records by employer

Hernandez Iron Works: OSHA inspections and violations

San Antonio, Texas · Ornamental and Architectural Metal Work Manufacturing · NAICS 332323

2inspections
7citation items
$19,514current penalties
Sep 13, 2022last inspection

OSHA has inspected Hernandez Iron Works 2 times in Texas since 2022.

The latest one began on Sep 13, 2022 to follow up on an earlier case, in San Antonio.

Those inspections ended with 7 citation items: 4 serious and 3 repeat.

Penalties were first proposed at $19,514 and still stand at $19,514.

Welding fire safety comes up most often in these citations: 2 items under 1910.252.

How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $3,600, and Hernandez Iron Works averages $9,757 (2 cited inspections).

Hernandez Iron Works: OSHA citation items per year, 2022 to 2022
Citation items per year, by inspection date.

Texas · latest 90 days of OSHA records

401employers cited

Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Texas

Checking a subcontractor, a client or your own company? Watch Hernandez Iron Works and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 346224355 OPENED SEP 13, 2022Closed

Follow-up · Partial · Safety · 3 employees at the site · Closed Sep 15, 2025

651 North General Mcmullen Drive, San Antonio, TX 78228 · Ornamental and Architectural Metal Work Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.212(a)(3)(ii) · Machine guarding
Repeat$4,018$4,018Jan 20, 2023Final
Citation 1, item 2
29 CFR 1910.252(b)(2)(iii) · Welding fire safety
Repeat$4,018$4,018Jan 20, 2023Final
Citation 1, item 3
29 CFR 1910.1200(e)(1) · Hazard communication
Repeat$4,018$4,018Jan 20, 2023Final

Inspection 345827893 OPENED MAR 9, 2022Closed

Planned · Partial · Health · 3 employees at the site · Closed Sep 15, 2025

651 North General Mcmullen Drive, San Antonio, TX 78228 · Ornamental and Architectural Metal Work Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.134(c)(1) · Respiratory protection
Serious$1,865$1,865May 27, 2022Final
Citation 1, item 2
29 CFR 1910.212(a)(3)(ii) · Machine guarding
Serious$1,865$1,865May 27, 2022Final
Citation 1, item 3
29 CFR 1910.252(b)(2)(iii) · Welding fire safety
Serious$1,865$1,865May 27, 2022Final
Citation 1, item 4
29 CFR 1910.1200(e)(1) · Hazard communication
Serious$1,865$1,865May 27, 2022Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(e)(1)

(e) Written hazard communication program. (1) Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met, and which also includes the following:

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.134(c)(1)

(1) The test instrument must have an effective audio-warning device, or a visual-warning device in the form of a screen tracing, that indicates when the test subject fails to hold his or her breath during the test. The test must be terminated and restarted from the beginning when the test subject fails to hold his or her breath during the test. The test subject then may be refitted and retested.

29 CFR 1910.212 · Machine guarding

29 CFR 1910.212(a)(3)(ii)

(ii) The point of operation of machines whose operation exposes an employee to injury, shall be guarded. The guarding device shall be in conformity with any appropriate standards therefor, or, in the absence of applicable specific standards, shall be so designed and constructed as to prevent the operator from having any part of his body in the danger zone during the operating cycle.

29 CFR 1910.252 · Welding fire safety