OSHA SearchOSHA records by employer

High Quality Builders, Inc.: OSHA inspections and violations

Warrington, Pennsylvania · Framing Contractors · NAICS 238130

3inspections
20citation items
$107,200current penalties
Oct 5, 2015last inspection

Since 2015, OSHA inspectors have visited High Quality Builders, Inc. in Pennsylvania 3 times.

The most recent inspection opened on Oct 5, 2015 on a referral, in West Chester.

In all, OSHA issued 20 citation items: 16 serious and 4 repeat.

The penalties, $107,200 in total, stand where OSHA first set them.

The rule cited most here is 1926.602 (earthmovers and forklifts in construction), 3 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. High Quality Builders, Inc. averages $35,733 across 3 cited inspections.

High Quality Builders, Inc.: OSHA citation items per year, 2015 to 2015
Citation items per year, by inspection date.

Pennsylvania · latest 90 days of OSHA records

285employers cited

6 of them in the same industry

Get notified the morning OSHA posts each new citation in Pennsylvania: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Pennsylvania

Checking a subcontractor, a client or your own company? Watch High Quality Builders, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 340990563 OPENED OCT 5, 2015Closed

Referral · Partial · Safety · 5 employees at the site · Closed Aug 30, 2018

1323 Wests Chester Pike, West Chester, PA 19382 · Siding Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(c)(2)(iv) · Scaffolds, general requirements
Serious$7,000$7,000Jan 4, 2016Final
Citation 1, item 1b
29 CFR 1926.602(c)(1)(ii) · Earthmovers and forklifts in construction
Serious$0$0Jan 4, 2016Final
Citation 1, item 2a
29 CFR 1926.451(c)(2)(v) · Scaffolds, general requirements
Serious$7,000$7,000Jan 4, 2016Final
Citation 1, item 2b
29 CFR 1926.602(c)(1)(vi) · Earthmovers and forklifts in construction
Serious$0$0Jan 4, 2016Final
Citation 1, item 3
29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements
Serious$7,000$7,000Jan 4, 2016Final
Citation 1, item 4a
29 CFR 1926.503(a)(1) · Fall protection training in construction
Serious$3,080$3,080Jan 4, 2016Final
Citation 1, item 4b
29 CFR 1926.20(b)(2) · Construction safety programs
Serious$0$0Jan 4, 2016Final
Citation 1, item 5
29 CFR 1926.602(c)(1)(vi) · Earthmovers and forklifts in construction
Serious$7,000$7,000Jan 4, 2016Final
Citation 2, item 1
29 CFR 1904.39(a)(2) · Reporting deaths and severe injuries
Repeat$11,000$11,000Jan 4, 2016Final
Citation 2, item 2
29 CFR 1926.501(b)(13) · Fall protection in construction
Repeat$30,800$30,800Jan 4, 2016Final

Inspection 340913862 OPENED JUL 27, 2015Closed

Complaint · Partial · Safety · 8 employees at the site · Closed Mar 8, 2022

2 Brinkmans Way Emerald Walk Development, Feasterville Trevose, PA 19053 · Framing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.20(b)(2) · Construction safety programs
Serious$3,080$3,080Nov 6, 2015Final
Citation 1, item 2a
29 CFR 1926.405(a)(2)(ii)(i) · Job-site wiring
Serious$2,200$2,200Nov 6, 2015Final
Citation 1, item 2b
29 CFR 1926.416(e)(1) · Electrical safety in construction
Serious$0$0Nov 6, 2015Final
Citation 2, item 1
29 CFR 1926.501(b)(13) · Fall protection in construction
Repeat$15,400$15,400Nov 6, 2015Final

Inspection 340603372 OPENED APR 27, 2015Closed

Unprogrammed other · Partial · Safety · 6 employees at the site · Closed Oct 1, 2019

Warrington Point Admiral Lane, Unit 19 Thru 22, Warrington, PA 18976 · Framing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.28(a) · Personal protective equipment
Serious$1,760$1,760Jul 15, 2015Final
Citation 1, item 2
29 CFR 1926.150(c)(1)(vi) · Fire protection
Serious$1,760$1,760Jul 15, 2015Final
Citation 1, item 3
29 CFR 1926.416(e)(1) · Electrical safety in construction
Serious$1,320$1,320Jul 15, 2015Final
Citation 1, item 4
29 CFR 1926.1053(b)(4) · Ladders in construction
Serious$1,760$1,760Jul 15, 2015Final
Citation 1, item 5
29 CFR 1926.1053(b)(13) · Ladders in construction
Serious$1,760$1,760Jul 15, 2015Final
Citation 2, item 1
29 CFR 1926.501(b)(13) · Fall protection in construction
Repeat$5,280$5,280Jul 15, 2015Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1904.39 · Reporting deaths and severe injuries

29 CFR 1904.39(a)(2)

(2) Within twenty-four (24) hours after the in-patient hospitalization of one or more employees or an employee's amputation or an employee's loss of an eye, as a result of a work-related incident, you must report the in-patient hospitalization, amputation, or loss of an eye to OSHA.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(13)

(13) The top or top step of a stepladder shall not be used as a step.

29 CFR 1926.1053(b)(4)

(4) Ladders shall be used only for the purpose for which they were designed.

29 CFR 1926.150 · Fire protection

29 CFR 1926.20 · Construction safety programs

29 CFR 1926.28 · Personal protective equipment

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.416 · Electrical safety in construction

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.503 · Fall protection training in construction

29 CFR 1926.602 · Earthmovers and forklifts in construction

Other framing contractors employers in Pennsylvania

Alert subscribers get notified of each newly cited employer in Pennsylvania the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.