Inspection 346388770 OPENED DEC 13, 2022Closed
3225 160th Street, Lawler, IA 52154 · Power and Communication Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Highline Construction, Inc has 4 OSHA inspections on record in Iowa, the first in 2009.
OSHA's last visit started on Dec 13, 2022 after a fatality or catastrophe, in Lawler.
Across those inspections OSHA issued 10 citation items: 9 serious and 1 other-than-serious.
OSHA proposed $23,500 in penalties. After settlements and reviews the total is $17,250, down 27%.
Most often, OSHA cited 1926.950, electric power transmission and distribution: general (3 items).
For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Highline Construction, Inc averages $6,000 over 1 cited inspection in that time.
1 inspection on this page followed a fatal incident.
Iowa · latest 90 days of OSHA records
69employers cited
Get notified the morning OSHA posts each new citation in Iowa: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in Iowa
Checking a subcontractor, a client or your own company? Watch Highline Construction, Inc and get notified the morning OSHA posts a new citation for it.
Watch this company3225 160th Street, Lawler, IA 52154 · Power and Communication Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
150th Ave And Hwy 9, Leland, IA 50453 · Power and Communication Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.960(c)(1)(iii)(a) · Working on or near exposed energized parts |
Serious | $6,000 | $6,000 | Apr 21, 2015 | Final |
3199 Scenic River Rd, Decorah, IA 52101 · Power and Communication Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps
Incident on Nov 23, 2013 (fatal): Lineman is electrocuted by contact with energized wire
On November 23, 2013, Employee #1, an electrical power line installer employed b y Highline Construction, was installing new electrical transmission lines. He fi nished hooking up a set of new, not-yet-energized power wires. He then had to ho ok up a jumper wire to the new wires. He made contact with one of the new wires that was lying on the ground and another wire from down the road. The latter wir e was energized and transmitting 7,200 volts of electricity. Employee #1 was ele ctrocuted.
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.21(b)(2) · Construction safety training |
Serious | $2,500 | $2,500 | Feb 6, 2014 | Closed |
| Citation 1, item 2 29 CFR 1926.950(c)(1)(i) · Electric Power Transmission and Distribution: general |
Serious | $2,500 | $2,500 | Feb 6, 2014 | Closed |
16003 County Road K-42, Whiting, IA 51063 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.20(b)(2) · Construction safety programs |
Serious | $2,500 | $1,250 | Jul 29, 2009 | Closed |
| Citation 1, item 2a 29 CFR 1926.453(b)(2)(i) · Aerial lifts |
Serious | $2,500 | $1,250 | Jul 29, 2009 | Closed |
| Citation 1, item 2b 29 CFR 1926.453(b)(2)(ii) · Aerial lifts |
Serious | $0 | $0 | Jul 29, 2009 | Closed |
| Citation 1, item 3 29 CFR 1926.453(b)(2)(v) · Aerial lifts |
Serious | $2,500 | $1,250 | Jul 29, 2009 | Closed |
| Citation 1, item 4 29 CFR 1926.454(a) · Scaffold training |
Other-than-serious | $2,500 | $1,250 | Jul 29, 2009 | Closed |
| Citation 1, item 5a 29 CFR 1926.950(b)(1) · Electric Power Transmission and Distribution: general |
Serious | $2,500 | $1,250 | Jul 29, 2009 | Closed |
| Citation 1, item 5b 29 CFR 1926.950(c)(1) · Electric Power Transmission and Distribution: general |
Serious | $0 | $0 | Jul 29, 2009 | Closed |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1926.20(b)(2)
(2) Such programs shall provide for frequent and regular inspections of the job sites, materials, and equipment to be made by competent persons designated by the employers.
29 CFR 1926.21(b)(2)
(2) The employer shall instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his work environment to control or eliminate any hazards or other exposure to illness or injury.
29 CFR 1926.453(b)(2)(i)
(2) Extensible and articulating boom platforms. (i) Lift controls shall be tested each day prior to use to determine that such controls are in safe working condition.
Alert subscribers get notified of each newly cited employer in Iowa the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.