OSHA SearchOSHA records by employer

Hme Inc: OSHA inspections and violations

Wyoming, Michigan · Automobile Manufacturing · NAICS 336111

5inspections
71citation items
$15,365current penalties
Jul 25, 2025last inspection

Since 1995, OSHA inspectors have visited Hme Inc in Michigan 5 times.

The most recent inspection opened on Jul 25, 2025 after a complaint, in Wyoming.

In all, OSHA issued 71 citation items: 35 serious, 5 repeat and 31 other-than-serious.

The proposed penalties came to $34,040; today they stand at $15,365, 55% less.

The rule cited most here is 1910.107 (spray painting and finishing), 10 times.

Among manufacturing employers, the typical cited inspection since 2015 ends with a $3,600 penalty. Hme Inc averages $2,400 across 2 cited inspections.

Hme Inc also files yearly injury logs with OSHA, summarized below.

Hme Inc: OSHA citation items per year, 1995 to 2025
Citation items per year, by inspection date.

Michigan · latest 90 days of OSHA records

670employers cited

2 of them in the same industry

Get notified the morning OSHA posts each new citation in Michigan: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Michigan

Checking a subcontractor, a client or your own company? Watch Hme Inc and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 348397811 OPENED JUL 25, 2025Closed

Complaint · Partial · Health · 175 employees at the site · Closed Feb 9, 2026

1950 Byron Center Ave, Wyoming, MI 49519 · Motor Vehicle Body Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 408.13312(1)
Serious$4,800$2,400Nov 20, 2025Final
Citation 1, item 1b
29 CFR 408.13394(1)
Serious$0$0Nov 20, 2025Final
Citation 1, item 1c
29 CFR 408.13386
Serious$0$0Nov 20, 2025Final
Citation 1, item 1d
29 CFR 325.47201(3)
Serious$0$0Nov 20, 2025Final
Citation 1, item 2a
29 CFR 1910.28(b)(1)(i) · Fall protection in general industry
Serious$4,800$2,400Nov 20, 2025Final
Citation 1, item 2b
29 CFR 1910.23(b)(8) · Ladders in general industry
Serious$0$0Nov 20, 2025Final

Inspection 344514575 OPENED DEC 19, 2019Closed

Complaint · Partial · Safety · 125 employees at the site · Closed May 7, 2020

1950 Byron Center Ave, Wyoming, MI 49519 · Motor Vehicle Body Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 408.10125
Other-than-serious$0$0Apr 8, 2020Final
Citation 1, item 2a
29 CFR 408.12131(1)
Other-than-serious$0$0Apr 8, 2020Final
Citation 1, item 2b
29 CFR 408.12154(1)
Other-than-serious$0$0Apr 8, 2020Final
Citation 1, item 3
29 CFR 1910.334(a)(2)(ii) · Using electrical equipment
Other-than-serious$0$0Apr 8, 2020Final
Citation 1, item 4
29 CFR 1910.106(d)(3)(ii)(a) · Flammable liquids
Other-than-serious$0$0Apr 8, 2020Final
Citation 1, item 5a
29 CFR 1910.107(b)(9) · Spray painting and finishing
Other-than-serious$0$0Apr 8, 2020Final
Citation 1, item 5b
29 CFR 1910.107(c)(6) · Spray painting and finishing
Other-than-serious$0$0Apr 8, 2020Final
Citation 1, item 5c
29 CFR 1910.107(e)(9) · Spray painting and finishing
Other-than-serious$0$0Apr 8, 2020Final
Citation 1, item 5d
29 CFR 1910.107(f)(3) · Spray painting and finishing
Other-than-serious$0$0Apr 8, 2020Final
Citation 1, item 5e
29 CFR 1910.107(g)(3) · Spray painting and finishing
Other-than-serious$0$0Apr 8, 2020Final
Citation 1, item 6
29 CFR 1910.1200(f)(6) · Hazard communication
Other-than-serious$0$0Apr 8, 2020Final

Inspection 315402990 OPENED JUN 6, 2013Closed

Planned · Complete · Safety · 90 employees at the site · Closed Aug 28, 2013

1950 Byron Center Ave Sw, Wyoming, MI 49519 · Automobile Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a Serious$2,100$1,050Jul 26, 2013Closed
Citation 1, item 1b Serious$0$0Jul 26, 2013Closed
Citation 1, item 1c Serious$0$0Jul 26, 2013Closed
Citation 1, item 2a Serious$900$360Jul 26, 2013Closed
Citation 1, item 2b Serious$0$0Jul 26, 2013Closed
Citation 1, item 3a Serious$900$360Jul 26, 2013Closed
Citation 1, item 3b Serious$0$0Jul 26, 2013Closed
Citation 1, item 4 Serious$900$450Jul 26, 2013Closed
Citation 1, item 5 Serious$900$450Jul 26, 2013Closed
Citation 1, item 6a Serious$1,200$600Jul 26, 2013Closed
Citation 1, item 6b Serious$0$0Jul 26, 2013Closed
Citation 1, item 7 Serious$900$360Jul 26, 2013Closed
Citation 1, item 8
29 CFR 1910.303(g)(2)(i) · Electrical equipment, general requirements
Serious$900$360Jul 26, 2013Closed
Citation 2, item 1 Repeat$1,800$900Jul 26, 2013Closed
Citation 2, item 2 Repeat$2,400$960Jul 26, 2013Closed
Citation 2, item 3 Repeat$1,800$720Jul 26, 2013Closed
Citation 3, item 1 Other-than-serious$0$0Jul 26, 2013Closed
Citation 3, item 2 Other-than-serious$0$0Jul 26, 2013Closed
Citation 3, item 3 Other-than-serious$0$0Jul 26, 2013Closed
Citation 3, item 4
29 CFR 1910.303(f)(1) · Electrical equipment, general requirements
Other-than-serious$0$0Jul 26, 2013Closed
Citation 3, item 5
29 CFR 1910.305(b)(2)(i) · Electrical wiring methods
Other-than-serious$0$0Jul 26, 2013Closed
Citation 3, item 6 Other-than-serious$0$0Jul 26, 2013Closed
Citation 3, item 7
29 CFR 1910.107(b)(10) · Spray painting and finishing
Other-than-serious$0$0Jul 26, 2013Closed
Citation 3, item 8
29 CFR 1910.107(e)(9) · Spray painting and finishing
Other-than-serious$0$0Jul 26, 2013Closed
Citation 3, item 9
29 CFR 1910.147(c)(6)(i) · Lockout/tagout
Other-than-serious$0$0Jul 26, 2013Closed
Citation 4, item 1 Repeat$120$60Jul 26, 2013Closed
Citation 4, item 2
29 CFR 1910.107(g)(3) · Spray painting and finishing
Repeat$120$60Jul 26, 2013Closed

Inspection 312036619 OPENED JAN 13, 2010Closed

Planned · Complete · Safety · 100 employees at the site · Closed Jun 10, 2010

1950 Byron Center Ave Sw, Wyoming, MI 49519 · Automobile Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Serious$750$300Mar 16, 2010Closed
Citation 1, item 2 Serious$750$300Mar 16, 2010Closed
Citation 1, item 3 Serious$750$300Mar 16, 2010Closed
Citation 1, item 4 Serious$750$300Mar 16, 2010Closed
Citation 1, item 5 Serious$750$300Mar 16, 2010Closed
Citation 1, item 6 Serious$750$300Mar 16, 2010Closed
Citation 1, item 7 Serious$750$300Mar 16, 2010Closed
Citation 1, item 8 Serious$750$300Mar 16, 2010Closed
Citation 1, item 9 Serious$750$300Mar 16, 2010Closed
Citation 1, item 10
29 CFR 1910.305(b)(1)(ii) · Electrical wiring methods
Serious$750$300Mar 16, 2010Closed
Citation 1, item 11 Serious$750$300Mar 16, 2010Closed
Citation 1, item 12a
29 CFR 1910.147(c)(4)(i) · Lockout/tagout
Serious$750$375Mar 16, 2010Closed
Citation 1, item 12b
29 CFR 1910.147(c)(5)(i) · Lockout/tagout
Serious$0$0Mar 16, 2010Closed
Citation 1, item 12c
29 CFR 1910.147(c)(7)(ia) · Lockout/tagout
Serious$0$0Mar 16, 2010Closed
Citation 1, item 12d
29 CFR 1910.147(c)(7)(ib) · Lockout/tagout
Serious$0$0Mar 16, 2010Closed
Citation 1, item 12e
29 CFR 1910.147(c)(7)(ic) · Lockout/tagout
Serious$0$0Mar 16, 2010Closed
Citation 2, item 1 Other-than-serious$0$0Mar 16, 2010Closed
Citation 2, item 2 Other-than-serious$0$0Mar 16, 2010Closed
Citation 2, item 3 Other-than-serious$0$0Mar 16, 2010Closed
Citation 2, item 4 Other-than-serious$0$0Mar 16, 2010Closed
Citation 2, item 5
29 CFR 1910.107(g)(3) · Spray painting and finishing
Other-than-serious$0$0Mar 16, 2010Closed
Citation 2, item 6a
29 CFR 1910.146(c)(1) · Permit-required confined spaces
Other-than-serious$0$0Mar 16, 2010Closed
Citation 2, item 6b
29 CFR 1910.146(c)(2) · Permit-required confined spaces
Other-than-serious$0$0Mar 16, 2010Closed
Citation 2, item 7
29 CFR 1910.1200(h)(1) · Hazard communication
Other-than-serious$0$0Mar 16, 2010Closed
Citation 3, item 1 Other-than-serious$500$200Mar 31, 2010Closed
Citation 3, item 2a
29 CFR 1910.134(c)(1) · Respiratory protection
Other-than-serious$0$0Mar 31, 2010Closed
Citation 3, item 2b
29 CFR 1910.107(b)(5)(i) · Spray painting and finishing
Other-than-serious$0$0Mar 31, 2010Closed

Inspection 114537806 OPENED APR 19, 1995Closed

Complaint · Partial · Health · 80 employees at the site · Closed May 25, 1995

1950 Byron Ctr Ave, Wyoming, MI 49509 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2025, the Wyoming site logged 3 recordable injuries or illnesses among about 197 workers: 1.4 per 100 full-time workers, against a median of 5.2 for its industry.

Site and yearWorkersCasesDays-away casesRateIndustry median
Hme
Wyoming · 2025
197 301.45.2
HME, Inc.
Wyoming · 2022
173 805.13.2
HME Main
Wyoming · 2018
168 603.53.2

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.106 · Flammable liquids

29 CFR 1910.106(d)(3)(ii)(a)

(ii) Fire resistance. Storage cabinets shall be designed and constructed to limit the internal temperature to not more than 325 °F. when subjected to a 10-minute fire test using the standard time-temperature curve as set forth in Standard Methods of Fire Tests of Building Construction and Materials, NFPA 251-1969, which is incorporated by reference as specified in § 1910.6. All joints and seams shall remain tight and the door shall remain securely closed during the fire test. Cabinets shall be labeled in conspicuous lettering, “Flammable—Keep Fire Away.”

29 CFR 1910.107 · Spray painting and finishing

29 CFR 1910.107(b)(10)

(10) Illumination. When spraying areas are illuminated through glass panels or other transparent materials, only fixed lighting units shall be used as a source of illumination. Panels shall effectively isolate the spraying area from the area in which the lighting unit is located, and shall be of a noncombustible material of such a nature or so protected that breakage will be unlikely. Panels shall be so arranged that normal accumulations of residue on the exposed surface of the panel will not be raised to a dangerous temperature by radiation or conduction from the source of illumination.

29 CFR 1910.107(b)(5)(i)

(i) The spraying operations except electrostatic spraying operations shall be so designed, installed and maintained that the average air velocity over the open face of the booth (or booth cross section during spraying operations) shall be not less than 100 linear feet per minute. Electrostatic spraying operations may be conducted with an air velocity over the open face of the booth of not less than 60 linear feet per minute, or more, depending on the volume of the finishing material being applied and its flammability and explosion characteristics. Visible gauges or audible alarm or pressure activated devices shall be installed to indicate or insure that the required air velocity is maintained. Filter rolls shall be inspected to insure proper replacement of filter media.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.146 · Permit-required confined spaces

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.23 · Ladders in general industry

29 CFR 1910.28 · Fall protection in general industry

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.334 · Using electrical equipment

29 CFR 3256.107

29 CFR 4081.1854

29 CFR 4081.187

29 CFR 4081.1872

29 CFR 4081.211

29 CFR 4081.213

29 CFR 4081.215

29 CFR 4081.2154

29 CFR 4081.2176

29 CFR 4081.221

29 CFR 4081.231

29 CFR 4081.233

29 CFR 4081.2355

29 CFR 4081.2373

29 CFR 4081.241

29 CFR 4081.2617

29 CFR 4081.2631

29 CFR 4081.2635

29 CFR 4081.33

29 CFR 4081.3312

29 CFR 4081.34

29 CFR 4081.4007

29 CFR 4081.454

29 CFR 4081.4923

29 CFR 4081.711

29 CFR 4081.722

29 CFR 4081.727

Other automobile manufacturing employers in Michigan

Alert subscribers get notified of each newly cited employer in Michigan the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.