Inspection 342979846 OPENED FEB 28, 2018Closed
862 W Fine Drive, Salt Lake City, UT 84119 · Industrial Machinery and Equipment Merchant Wholesalers · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Salt Lake City, Utah · Industrial Machinery and Equipment Merchant Wholesalers · NAICS 423830
Hoj Engineering and Sales Co. Inc. has 6 OSHA inspections on record in Utah, the first in 1983.
OSHA's last visit started on Feb 28, 2018 after an accident, in Salt Lake City.
Across those inspections OSHA issued 11 citation items: 6 serious and 5 other-than-serious.
OSHA proposed $3,760 in penalties. After settlements and reviews the total is $2,885, down 23%.
For context, across all wholesale employers the median penalty per cited inspection since 2015 is $3,424. Hoj Engineering and Sales Co. Inc. averages $875 over 1 cited inspection in that time.
Utah · latest 90 days of OSHA records
73employers cited
Get notified the morning OSHA posts each new citation in Utah: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in Utah
Checking a subcontractor, a client or your own company? Watch Hoj Engineering and Sales Co. Inc. and get notified the morning OSHA posts a new citation for it.
Watch this company862 W Fine Drive, Salt Lake City, UT 84119 · Industrial Machinery and Equipment Merchant Wholesalers · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
862 W Fine St., South Salt Lake, UT 84119 · Industrial Machinery and Equipment Merchant Wholesalers · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.215(b)(9) · Grinders and abrasive wheels |
Serious | $1,750 | $875 | Jan 19, 2018 | Final |
3960 South 500 West, Salt Lake City, UT 84123 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1910.178(l) · Forklifts and other powered industrial trucks |
Serious | $1,650 | $1,650 | Mar 4, 1996 | Closed |
| Citation 1, item 1b 29 CFR 1910.243(c)(3) · Guarding of portable powered tools |
Serious | $0 | $0 | Mar 4, 1996 | Closed |
| Citation 2, item 1 29 CFR 1910.134(a)(2) · Respiratory protection |
Other-than-serious | $0 | $0 | Mar 4, 1996 | Closed |
| Citation 2, item 2 29 CFR 1910.157(c)(1) · Portable fire extinguishers |
Other-than-serious | $0 | $0 | Mar 4, 1996 | Closed |
| Citation 2, item 3 29 CFR 1910.213(i)(1) · Woodworking machinery |
Other-than-serious | $0 | $0 | Mar 4, 1996 | Closed |
| Citation 2, item 4 29 CFR 1910.219(e)(1)(i) · Belts, pulleys and power-transmission parts |
Serious | $0 | $0 | Mar 4, 1996 | Closed |
| Citation 2, item 5 29 CFR 1910.252(b)(2)(iii) · Welding fire safety |
Other-than-serious | $0 | $0 | Mar 4, 1996 | Closed |
| Citation 2, item 6 29 CFR 1910.1200(e)(1) · Hazard communication |
Other-than-serious | $0 | $0 | Mar 4, 1996 | Closed |
620 West 600 North, North Salt Lake, UT 84054 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR CON005501 |
Serious | $160 | $160 | Nov 8, 1988 | Closed |
St. George Power Plant, St. George, UT 84770 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR CON002801 |
Serious | $200 | $200 | Aug 21, 1986 | Closed |
3960 South 500 West, Salt Lake City, UT 84107 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1910.1200(e)(1)
(e) Written hazard communication program. (1) Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met, and which also includes the following:
29 CFR 1910.134(a)(2)
(2) The CNP system defaults selected for test pressure shall be set at −15 mm of water (-0.58 inches of water) and the modeled inspiratory flow rate shall be 53.8 liters per minute for performing fit tests.
29 CFR 1910.157(c)(1)
(c) General requirements. (1) The employer shall provide portable fire extinguishers and shall mount, locate and identify them so that they are readily accessible to employees without subjecting the employees to possible injury.
Alert subscribers get notified of each newly cited employer in Utah the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.