OSHA SearchOSHA records by employer

Homedge, LLC: OSHA inspections and violations

Mesa, Arizona · Wood Kitchen Cabinet and Countertop Manufacturing · NAICS 337110

1inspections
2citation items
$0current penalties
Apr 22, 2015last inspection

Homedge, LLC has one OSHA inspection on record in Arizona.

OSHA opened it on Apr 22, 2015 after a complaint, in Mesa.

From that inspection OSHA issued 2 citation items: 2 other-than-serious.

OSHA did not attach a penalty to any of these citations.

Most often, OSHA cited 1910.107, spray painting and finishing (2 items).

For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $3,600. Homedge, LLC averages $0 over 1 cited inspection in that time.

Homedge, LLC: OSHA citation items per year, 2015 to 2015
Citation items per year, by inspection date.

Arizona · latest 90 days of OSHA records

85employers cited

Get notified the morning OSHA posts each new citation in Arizona: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Arizona

Checking a subcontractor, a client or your own company? Watch Homedge, LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 340590298 OPENED APR 22, 2015Closed

Complaint · Partial · Health · 26 employees at the site · Closed Aug 27, 2015

1301 W Broadway Rd, Mesa, AZ 85202 · Wood Kitchen Cabinet and Countertop Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.107(b)(5)(iv) · Spray painting and finishing
Other-than-serious$0$0Aug 17, 2015Final
Citation 1, item 2
29 CFR 1910.107(b)(10) · Spray painting and finishing
Other-than-serious$0$0Aug 17, 2015Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.107 · Spray painting and finishing

29 CFR 1910.107(b)(10)

(10) Illumination. When spraying areas are illuminated through glass panels or other transparent materials, only fixed lighting units shall be used as a source of illumination. Panels shall effectively isolate the spraying area from the area in which the lighting unit is located, and shall be of a noncombustible material of such a nature or so protected that breakage will be unlikely. Panels shall be so arranged that normal accumulations of residue on the exposed surface of the panel will not be raised to a dangerous temperature by radiation or conduction from the source of illumination.

29 CFR 1910.107(b)(5)(iv)

(iv) Space within the spray booth on the downstream and upstream sides of filters shall be protected with approved automatic sprinklers.

Other wood kitchen cabinet and countertop manufacturing employers in Arizona

Alert subscribers get notified of each newly cited employer in Arizona the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.