OSHA SearchOSHA records by employer

Horticopia Landscaping LLC: OSHA inspections and violations

Siesta Key, Florida · Landscaping Services · NAICS 561730

1inspections
2citation items
$13,027current penalties
Sep 25, 2017last inspection

Horticopia Landscaping LLC has one OSHA inspection on record in Florida.

OSHA opened it on Sep 25, 2017 after a fatality or catastrophe, in Siesta Key.

From that inspection OSHA issued 2 citation items: 2 serious.

OSHA proposed $15,706 in penalties. After settlements and reviews the total is $13,027, down 17%.

For context, across all staffing, cleaning and waste services employers the median penalty per cited inspection since 2015 is $2,208. Horticopia Landscaping LLC averages $13,027 over 1 cited inspection in that time.

1 inspection on this page followed a fatal incident.

Horticopia Landscaping LLC: OSHA citation items per year, 2017 to 2017
Citation items per year, by inspection date.

Florida · latest 90 days of OSHA records

320employers cited

9 of them in the same industry

Get notified the morning OSHA posts each new citation in Florida: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Florida

Checking a subcontractor, a client or your own company? Watch Horticopia Landscaping LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342660396 OPENED SEP 25, 2017Closed

Fatality or catastrophe · Complete · Safety · 3 employees at the site · Closed Mar 12, 2019

684 Freeling Drive, Siesta Key, FL 34242 · Landscaping Services · OSHA's record · Phone and website on Google Maps

Incident on Sep 24, 2017 (fatal): Employee is electrocuted when aerial lift contacts overhead

At 3:00 p.m. on September 24, 2017, an employee was cutting trees close to energized power line from an aerial lift. The trees had been damaged, broken,and bent by Hurricane Irma. The aerial platform made contact with the power line. The employee was electrocuted.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.67(c)(2)(v) · Vehicle-mounted elevating and rotating work platforms
Serious$2,772$1,386Feb 23, 2018Final
Citation 1, item 2
29 CFR 1910.333(c)(3)(iii)(a) · Working near live electrical parts
Serious$12,934$11,641Feb 23, 2018Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.333 · Working near live electrical parts

29 CFR 1910.333(c)(3)(iii)(a)

(iii) Vehicular and mechanical equipment. (A) Any vehicle or mechanical equipment capable of having parts of its structure elevated near energized overhead lines shall be operated so that a clearance of 10 ft. (305 cm) is maintained. If the voltage is higher than 50kV, the clearance shall be increased 4 in. (10 cm) for every 10kV over that voltage. However, under any of the following conditions, the clearance may be reduced:

29 CFR 1910.67 · Vehicle-mounted elevating and rotating work platforms

29 CFR 1910.67(c)(2)(v)

(v) A personal fall arrest or travel restraint system that meets the requirements in subpart I of this part shall be worn and attached to the boom or basket when working from an aerial lift.

Other landscaping services employers in Florida

Alert subscribers get notified of each newly cited employer in Florida the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.