OSHA SearchOSHA records by employer

Hostetter Homes LLC: OSHA inspections and violations

South Boston, Massachusetts · Residential Remodelers · NAICS 236118

1inspections
5citation items
$8,800current penalties
Nov 13, 2017last inspection

Hostetter Homes LLC has one OSHA inspection on record in Massachusetts.

OSHA opened it on Nov 13, 2017 after a complaint, in South Boston.

From that inspection OSHA issued 5 citation items: 4 serious and 1 other-than-serious.

OSHA proposed $27,887 in penalties. After settlements and reviews the total is $8,800, down 68%.

Most often, OSHA cited 1926.850, preparatory operations (2 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Hostetter Homes LLC averages $8,800 over 1 cited inspection in that time.

Hostetter Homes LLC: OSHA citation items per year, 2017 to 2017
Citation items per year, by inspection date.

Massachusetts · latest 90 days of OSHA records

247employers cited

5 of them in the same industry

Get notified the morning OSHA posts each new citation in Massachusetts: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Massachusetts

Checking a subcontractor, a client or your own company? Watch Hostetter Homes LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342766284 OPENED NOV 13, 2017Closed

Complaint · Partial · Safety · 45 employees at the site · Closed Mar 2, 2020

719-721 East 2nd Street, South Boston, MA 02127 · Residential Remodelers · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.850(a) · Preparatory operations
Serious$8,873$4,400Dec 27, 2017Final
Citation 1, item 1b Serious$0$0Dec 27, 2017Final
Citation 1, item 2a
29 CFR 1926.850(c) · Preparatory operations
Serious$8,873$4,400Dec 27, 2017Final
Citation 1, item 2b
29 CFR 1926.851(a) · Stairs, passageways, and ladders
Serious$8,873$0Dec 27, 2017Final
Citation 2, item 1
29 CFR 1904.40(a) · Giving injury records to OSHA
Other-than-serious$1,268$0Dec 27, 2017Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1904.40 · Giving injury records to OSHA

29 CFR 1904.40(a)

(a) Basic requirement. When an authorized government representative asks for the records you keep under part 1904, you must provide copies of the records within four (4) business hours.

29 CFR 1926.850 · Preparatory operations

29 CFR 1926.850(a)

(a) Prior to permitting employees to start demolition operations, an engineering survey shall be made, by a competent person, of the structure to determine the condition of the framing, floors, and walls, and possibility of unplanned collapse of any portion of the structure. Any adjacent structure where employees may be exposed shall also be similarly checked. The employer shall have in writing evidence that such a survey has been performed.

29 CFR 1926.850(c)

(c) All electric, gas, water, steam, sewer, and other service lines shall be shut off, capped, or otherwise controlled, outside the building line before demolition work is started. In each case, any utility company which is involved shall be notified in advance.

29 CFR 1926.851 · Stairs, passageways, and ladders

29 CFR 1926.857 · Storage

Other residential remodelers employers in Massachusetts

Alert subscribers get notified of each newly cited employer in Massachusetts the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.