Houston Roll Pipe & Welding Steel LLC: OSHA inspections and violations

Houston, Texas · Plate Work Manufacturing · NAICS 332313

2inspections
2citation items
$7,252current penalties
Mar 16, 2023last inspection

Houston Roll Pipe & Welding Steel LLC has 2 OSHA inspections on record in Texas, the first in 2022.

OSHA's last visit started on Mar 16, 2023 as a planned inspection, in Houston.

Across those inspections OSHA issued 2 citation items: 2 serious.

OSHA proposed $7,252 in penalties and the amount has not been reduced.

For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $3,600. Houston Roll Pipe & Welding Steel LLC averages $7,252 over 1 cited inspection in that time.

Houston Roll Pipe & Welding Steel LLC: OSHA citation items per year, 2022 to 2023
Citation items per year, by inspection date.

Texas · latest 90 days of OSHA records

403employers cited

Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Texas

Checking a subcontractor, a client or your own company? Watch Houston Roll Pipe & Welding Steel LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 346572639 OPENED MAR 16, 2023Closed

Planned · No inspection · Safety · 40 employees at the site · Closed Mar 17, 2023

4122 Creekmont Dr., Houston, TX 77091 · Plate Work Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 346325228 OPENED NOV 2, 2022Closed

Planned · Partial · Safety · 40 employees at the site · Closed Apr 20, 2023

4122 Creekmont Dr., Houston, TX 77091 · Plate Work Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.303(f)(2) · Electrical equipment, general requirements
Serious$7,252$7,252Jan 3, 2023Final
Citation 1, item 1b
29 CFR 1910.305(b)(1)(ii) · Electrical wiring methods
Serious$0$0Jan 3, 2023Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.303(f)(2)

(2) Services, feeders, and branch circuits. Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, shall be legibly marked to indicate its purpose, unless located and arranged so the purpose is evident.

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.305(b)(1)(ii)

(ii) Unused openings in cabinets, boxes, and fittings shall be effectively closed.