OSHA SearchOSHA records by employer

HSG, LLC dba High Speed Gear: OSHA inspections and violations

Swansboro, North Carolina · All Other Miscellaneous Textile Product Mills · NAICS 314999

1inspections
10citation items
$6,525current penalties
Jan 14, 2015last inspection

HSG, LLC dba High Speed Gear has one OSHA inspection on record in North Carolina.

OSHA opened it on Jan 14, 2015 after a complaint, in Swansboro.

From that inspection OSHA issued 10 citation items: 4 serious and 6 other-than-serious.

OSHA proposed $6,750 in penalties. After settlements and reviews the total is $6,525, down 3%.

Most often, OSHA cited 1910.1200, hazard communication (6 items).

For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $4,859. HSG, LLC dba High Speed Gear averages $6,525 over 1 cited inspection in that time.

HSG, LLC dba High Speed Gear: OSHA citation items per year, 2015 to 2015
Citation items per year, by inspection date.

North Carolina · latest 90 days of OSHA records

231employers cited

Get notified the morning OSHA posts each new citation in North Carolina: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in North Carolina

Checking a subcontractor, a client or your own company? Watch HSG, LLC dba High Speed Gear and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 317943801 OPENED JAN 14, 2015Closed

Complaint · Partial · Health · 60 employees at the site · Closed Apr 14, 2015

87 Old Hammock Rd, Swansboro, NC 28584 · All Other Miscellaneous Textile Product Mills · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.106(e)(6)(ii) · Flammable liquids
Serious$1,500$1,500Feb 6, 2015Closed
Citation 1, item 2
29 CFR 1910.106(e)(3)(v)(a) · Flammable liquids
Serious$1,500$1,500Feb 6, 2015Closed
Citation 1, item 3
29 CFR 1910.307(c)(2)(i) · Hazardous (classified) locations
Serious$1,500$1,500Feb 6, 2015Closed
Citation 1, item 4
29 CFR 1910.212(a)(1) · Machine guarding
Serious$750$675Feb 6, 2015Closed
Citation 1, item 5a
29 CFR 1910.1200(e)(1) · Hazard communication
Other-than-serious$750$675Feb 6, 2015Closed
Citation 1, item 5b
29 CFR 1910.1200(g)(8) · Hazard communication
Other-than-serious$0$0Feb 6, 2015Closed
Citation 1, item 5c
29 CFR 1910.1200(h)(1) · Hazard communication
Other-than-serious$0$0Feb 6, 2015Closed
Citation 2, item 1a
29 CFR 1910.1200(e)(1) · Hazard communication
Other-than-serious$750$675Feb 6, 2015Closed
Citation 2, item 1b
29 CFR 1910.1200(g)(8) · Hazard communication
Other-than-serious$0$0Feb 6, 2015Closed
Citation 2, item 1c
29 CFR 1910.1200(h)(1) · Hazard communication
Other-than-serious$0$0Feb 6, 2015Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.106 · Flammable liquids

29 CFR 1910.106(e)(3)(v)(a)

(v) Ventilation—(a) Areas as defined in paragraph (e)(3)(i) of this section using Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), shall be ventilated at a rate of not less than 1 cubic foot per minute per square foot of solid floor area. This shall be accomplished by natural or mechanical ventilation with discharge or exhaust to a safe location outside of the building. Provision shall be made for introduction of makeup air in such a manner as not to short circuit the ventilation. Ventilation shall be arranged to include all floor areas or pits where flammable vapors may collect.

29 CFR 1910.106(e)(6)(ii)

(ii) Grounding. Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), shall not be dispensed into containers unless the nozzle and container are electrically interconnected. Where the metallic floorplate on which the container stands while filling is electrically connected to the fill stem or where the fill stem is bonded to the container during filling operations by means of a bond wire, the provisions of this section shall be deemed to have been complied with.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(e)(1)

(e) Written hazard communication program. (1) Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met, and which also includes the following:

29 CFR 1910.212 · Machine guarding

29 CFR 1910.307 · Hazardous (classified) locations

Other all other miscellaneous textile product mills employers in North Carolina