OSHA SearchOSHA records by employer

HW Metal Products Inc: OSHA inspections and violations

Tualatin, Oregon · Sheet Metal Work Manufacturing · NAICS 332322

14inspections
32citation items
$6,240current penalties
Aug 22, 2024last inspection

HW Metal Products Inc has 14 OSHA inspections on record in Oregon, the first in 2001.

OSHA's last visit started on Aug 22, 2024 as a planned inspection, in Tualatin.

Across those inspections OSHA issued 32 citation items: 15 serious and 17 other-than-serious.

OSHA proposed $6,240 in penalties and the amount has not been reduced.

Most often, OSHA cited 1910.305, electrical wiring methods (4 items).

For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $3,600. HW Metal Products Inc averages $1,168 over 5 cited inspections in that time.

HW Metal Products Inc: OSHA citation items per year, 2001 to 2024
Citation items per year, by inspection date.

Oregon · latest 90 days of OSHA records

385employers cited

2 of them in the same industry

Get notified the morning OSHA posts each new citation in Oregon: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Oregon

Checking a subcontractor, a client or your own company? Watch HW Metal Products Inc and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347832396 OPENED AUG 22, 2024Closed

Planned · Complete · Safety · 60 employees at the site · Closed Feb 11, 2025

19480 Sw 118th Ave, Tualatin, OR 97062 · Sheet Metal Work Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR OAR 437-002-0228(2)(A)
Other-than-serious$0$0Nov 25, 2024Final
Citation 1, item 1b
29 CFR OAR 437-002-0228(2)(C)
Other-than-serious$0$0Nov 25, 2024Final
Citation 1, item 2 Other-than-serious$0$0Nov 25, 2024Final
Citation 1, item 3
29 CFR OAR 437-002-0187(1)-7
Other-than-serious$0$0Nov 25, 2024Final
Citation 1, item 4a
29 CFR 1910.303(b)(2) · Electrical equipment, general requirements
Other-than-serious$0$0Nov 25, 2024Final
Citation 1, item 4b
29 CFR 1910.305(a)(2)(i) · Electrical wiring methods
Other-than-serious$0$0Nov 25, 2024Final

Inspection 345832323 OPENED MAR 10, 2022Closed

Planned · No inspection · Health · Closed Mar 10, 2022

19480 Sw 118th Ave, Tualatin, OR 97062 · Sheet Metal Work Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 343690434 OPENED JAN 3, 2019Closed

Planned · Complete · Safety · 90 employees at the site · Closed Sep 13, 2019

19480 Sw 118th Ave, Tualatin, OR 97062 · Sheet Metal Work Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.28(b)(1)(i) · Fall protection in general industry
Serious$1,750$1,750Feb 14, 2019Final
Citation 1, item 2
29 CFR 1910.212(a)(3)(ii) · Machine guarding
Serious$350$350Feb 14, 2019Final
Citation 1, item 3
29 CFR 1910.147(c)(4)(i) · Lockout/tagout
Serious$350$350Feb 14, 2019Final
Citation 1, item 4
29 CFR OAR 437-002-0022(4)(F)
Serious$150$150Feb 14, 2019Final
Citation 1, item 5
29 CFR 1910.22(a)(3) · Walking-working surfaces
Serious$350$350Feb 14, 2019Final
Citation 2, item 6
29 CFR 1910.147(c)(7)(iv) · Lockout/tagout
Other-than-serious$0$0Feb 14, 2019Final

Inspection 343424305 OPENED AUG 27, 2018Closed

Complaint · Partial · Safety · 62 employees at the site · Closed Jan 17, 2019

19480 Sw 118th Ave, Tualatin, OR 97062 · Sheet Metal Work Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.178(l)(2)(ii) · Forklifts and other powered industrial trucks
Other-than-serious$0$0Sep 27, 2018Final

Inspection 342498797 OPENED JUL 26, 2017Closed

Accident · Partial · Safety · 65 employees at the site · Closed Mar 26, 2018

19480 Sw 118th Ave, Tualatin, OR 97062 · Sheet Metal Work Manufacturing · OSHA's record · Phone and website on Google Maps

Incident on Jul 19, 2017: Employee is moving stack of metal plates and amputates finge

At 7:00 a.m. on July 19, 2017, an employee was using an overhead bridge crane to move a stack of formed plates in the welding area. The employee lifted the stack with the crane while his left hand was on the load. The employee amputated the tip of his left index finger when the sharp metal shifted and caught his finger.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR OAR 437-001-0704(4)
Other-than-serious$250$250Nov 1, 2017Final
Citation 1, item 2
29 CFR OAR 437-001-0765(6)-8
Other-than-serious$0$0Nov 1, 2017Final

Inspection 340687888 OPENED APR 23, 2015Closed

Planned · Complete · Safety · 66 employees at the site · Closed Oct 1, 2015

19480 Sw 118th Ave, Tualatin, OR 97062 · Sheet Metal Work Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.23(c)(1) · Guarding floor and wall openings and holes
Serious$1,260$1,260Jun 11, 2015Final
Citation 1, item 2
29 CFR OAR 437-001-0760(1)(B)(D)
Serious$300$300Jun 11, 2015Final
Citation 1, item 3
29 CFR OAR 437-002-0134(1)(A)
Serious$300$300Jun 11, 2015Final
Citation 1, item 4a
29 CFR OAR 437-002-0228(2)(A)
Serious$300$300Jun 11, 2015Final
Citation 1, item 4b
29 CFR OAR 437-002-0228(2)(D)
Serious$0$0Jun 11, 2015Final
Citation 1, item 5a
29 CFR 1910.179(j)(2)(iii) · Overhead and gantry cranes
Serious$300$300Jun 11, 2015Final
Citation 1, item 5b
29 CFR 1910.179(j)(2)(iv) · Overhead and gantry cranes
Serious$0$0Jun 11, 2015Final
Citation 1, item 6
29 CFR 1910.147(c)(6)(i) · Lockout/tagout
Serious$180$180Jun 11, 2015Final
Citation 2, item 7
29 CFR OAR 437-001-0765(5)-3
Other-than-serious$0$0Jun 11, 2015Final

Inspection 312298995 OPENED JUL 18, 2008Closed

Accident · Partial · Safety · 6 employees at the site · Closed Nov 5, 2008

19480 Sw 118th Ave, Tualatin, OR 97062 · Metal Service Centers and Other Metal Merchant Wholesalers · OSHA's record · Phone and website on Google Maps

Incident on Jul 7, 2008: Employee fractures hand while operating press brake

Employee #1 was forming a part on the press brake. Employee #1's hand was caught between the metal that was being formed and the staging table of the bottom die s of the press brake. Employee #1 sustained a fractured hand and was hospitalize d.

No citations from this inspection.

Inspection 311698005 OPENED APR 1, 2008Closed

Accident · Partial · Safety · 53 employees at the site · Closed Dec 1, 2008

19480 Sw 118th Ave, Tualatin, OR 97062 · Metal Service Centers and Other Metal Merchant Wholesalers · OSHA's record · Phone and website on Google Maps

Incident on Mar 25, 2008: Employee's finger is amputated by burning machine

On March 25, 2008, Employee #1 was injured when his gloved hand became caught be tween the pinion and the track of a burning machine. He was hospitalized for the amputation of the middle finger of his right hand.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Serious$300$300Aug 4, 2008Closed
6 older inspections

Inspection 311691687 OPENED DEC 11, 2007Closed

Follow-up · Partial · Safety · 44 employees at the site · Closed Dec 11, 2007

19480 Sw 118th Ave, Tualatin, OR 97062 · Sheet Metal Work Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 311174585 OPENED OCT 25, 2007Closed

Planned · Complete · Safety · 44 employees at the site · Closed Mar 10, 2008

19480 Sw 118th Ave, Tualatin, OR 97062 · Metal Service Centers and Other Metal Merchant Wholesalers · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.305(b)(1) · Electrical wiring methods
Other-than-serious$0$0Nov 21, 2007Closed
Citation 1, item 2
29 CFR 1910.305(g)(1)(iiib) · Electrical wiring methods
Other-than-serious$0$0Nov 21, 2007Closed
Citation 1, item 3
29 CFR 1910.334(a)(2)(ii) · Using electrical equipment
Other-than-serious$0$0Nov 21, 2007Closed
Citation 1, item 4
29 CFR 1910.305(b)(2) · Electrical wiring methods
Other-than-serious$0$0Nov 21, 2007Closed

Inspection 307464966 OPENED MAR 11, 2004Closed

Planned · No inspection · Safety · Closed Mar 11, 2004

Sw 118th, Tualatin, OR 97062 · Fabricated Structural Metal Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 305557936 OPENED AUG 1, 2002Closed

Planned · Complete · Safety · 35 employees at the site · Closed Dec 31, 2002

19480 Sw 118th Ave, Tualatin, OR 97062 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.215(a)(4) · Grinders and abrasive wheels
Serious$100$100Sep 10, 2002Closed
Citation 2, item 2
29 CFR 1910.1200(e)(1) · Hazard communication
Other-than-serious$0$0Sep 10, 2002Closed

Inspection 304229594 OPENED SEP 6, 2001Closed

Planned · Complete · Safety · 30 employees at the site · Closed Apr 3, 2002

19480 Sw 118th, Tualatin, OR 97062 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.157(c)(1) · Portable fire extinguishers
Other-than-serious$0$0Oct 17, 2001Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(e)(1)

(e) Written hazard communication program. (1) Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met, and which also includes the following:

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.147(c)(4)(i)

(4) Energy control procedure. (i) Procedures shall be developed, documented and utilized for the control of potentially hazardous energy when employees are engaged in the activities covered by this section.

29 CFR 1910.147(c)(5)(ii)(d)

(D) Identifiable. Lockout devices and tagout devices shall indicate the identity of the employee applying the device(s).

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.179 · Overhead and gantry cranes

29 CFR 1910.212 · Machine guarding

29 CFR 1910.215 · Grinders and abrasive wheels

29 CFR 1910.22 · Walking-working surfaces

29 CFR 1910.23 · Guarding floor and wall openings and holes

29 CFR 1910.28 · Fall protection in general industry

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.334 · Using electrical equipment

29 CFR 7010.7600

Other sheet metal work manufacturing employers in Oregon

Alert subscribers get notified of each newly cited employer in Oregon the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.