OSHA SearchOSHA records by employer

Hydro Resources - Rocky Mountain, Inc.: OSHA inspections and violations

Keenesburg, Colorado · Water and Sewer Line and Related Structures Construction · NAICS 237110

1inspections
5citation items
$8,600current penalties
Apr 25, 2019last inspection

Hydro Resources - Rocky Mountain, Inc. has one OSHA inspection on record in Colorado.

OSHA opened it on Apr 25, 2019 on a referral, in Keenesburg.

From that inspection OSHA issued 5 citation items: 5 serious.

OSHA proposed $10,144 in penalties. After settlements and reviews the total is $8,600, down 15%.

Most often, OSHA cited 1910.1200, hazard communication (3 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Hydro Resources - Rocky Mountain, Inc. averages $8,600 over 1 cited inspection in that time.

It reported 1 severe injury to OSHA since 2015.

Hydro Resources - Rocky Mountain, Inc.: OSHA citation items per year, 2019 to 2019
Citation items per year, by inspection date.

Colorado · latest 90 days of OSHA records

142employers cited

3 of them in the same industry

Get notified the morning OSHA posts each new citation in Colorado: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Colorado

Checking a subcontractor, a client or your own company? Watch Hydro Resources - Rocky Mountain, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343958773 OPENED APR 25, 2019Closed

Referral · Partial · Safety · 74 employees at the site · Closed Jul 31, 2019

34693 Weld County Road 18, Keenesburg, CO 80643 · Water and Sewer Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps

Incident on Apr 23, 2019: Employee is injured when detonation cord explodes

At 9:00 a.m. on April 23, 2019, Employee #1, employed by a construction company, was installing a detonation cord into a water well. The detonation cord exploded in the employee's left hand. The employee was transported to the hospital, where he was admitted for treatment of burns and shrapnel wounds/lacerations from the blasting cap.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.109(e)(1)(iv) · Explosives and blasting agents
Serious$5,636$5,000Jul 10, 2019Final
Citation 1, item 1b
29 CFR 1910.109(e)(1)(vii) · Explosives and blasting agents
Serious$0$0Jul 10, 2019Final
Citation 1, item 3a
29 CFR 1910.1200(f)(6) · Hazard communication
Serious$4,508$3,600Jul 10, 2019Final
Citation 1, item 3b
29 CFR 1910.1200(g)(8) · Hazard communication
Serious$0$0Jul 10, 2019Final
Citation 1, item 3c
29 CFR 1910.1200(h)(3)(i) · Hazard communication
Serious$0$0Jul 10, 2019Final

Severe injury reports

Employers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 1 report on file.

Apr 23, 2019, Keenesburg: Hospitalization · puncture wounds, except gunshot wounds · upper and lower limb(s)

An employee was attaching a detonation cord to a power source when a static charge set off a length of the detonation cord with three charges attached. Two employees were struck by multiple explosive fragments in the arms and legs, requiring hospitalization.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.109 · Explosives and blasting agents

29 CFR 1910.109(e)(1)(iv)

(iv) Persons authorized to prepare explosive charges or conduct blasting operations shall use every reasonable precaution, including but not limited to warning signals, flags, barricades, or woven wire mats to insure the safety of the general public and workmen.

29 CFR 1910.109(e)(1)(vii)

(vii) Due precautions shall be taken to prevent accidental discharge of electric blasting caps from current induced by radar, radio transmitters, lightning, adjacent powerlines, dust storms, or other sources of extraneous electricity. These precautions shall include:

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(f)(6)

(6) Workplace labeling. Except as provided in paragraphs (f)(7) and (f)(8) of this section, the employer shall ensure that each container of hazardous chemicals in the workplace is labeled, tagged or marked with either:

Other water and sewer line and related structures construction employers in Colorado

Alert subscribers get notified of each newly cited employer in Colorado the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.