OSHA SearchOSHA records by employer

Hynes Industries, Inc.: OSHA inspections and violations

Youngstown, Ohio · Custom Roll Forming · NAICS 332114

8inspections
24citation items
$17,129current penalties
Aug 8, 2016last inspection

Hynes Industries, Inc. has 8 OSHA inspections on record in Ohio, the first in 1974.

OSHA's last visit started on Aug 8, 2016 after a complaint, in Youngstown.

Across those inspections OSHA issued 24 citation items: 15 serious and 9 other-than-serious.

OSHA proposed $25,052 in penalties. After settlements and reviews the total is $17,129, down 32%.

Most often, OSHA cited 1910.217, mechanical power presses (7 items).

For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $3,600. Hynes Industries, Inc. averages $13,469 over 1 cited inspection in that time.

Hynes Industries, Inc. also files yearly injury logs with OSHA, summarized below.

Hynes Industries, Inc.: OSHA citation items per year, 1974 to 2016
Citation items per year, by inspection date.

Ohio · latest 90 days of OSHA records

265employers cited

Get notified the morning OSHA posts each new citation in Ohio: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Ohio

Checking a subcontractor, a client or your own company? Watch Hynes Industries, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Company-wide record

OSHA records show Hynes Industries, Inc. at 2 sites in 2 states. Together they've had 9 inspections and $21,854 in current penalties.

We match records by employer name and industry, so these sites are likely the same company, not certainly. Franchises and subsidiaries can file under one name.

Included with any plan: the site-by-site record for all 2 sites, with repeat and willful violations and citations per year for the whole company. Already a subscriber? Sign in.

See plans

Inspection history

Inspection 341682847 OPENED AUG 8, 2016Closed

Complaint · Partial · Safety · 180 employees at the site · Closed Sep 30, 2016

3805 Hendricks Road, Youngstown, OH 44555 · Custom Roll Forming · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.147(c)(4)(i) · Lockout/tagout
Serious$8,017$5,612Sep 1, 2016Final
Citation 1, item 1b
29 CFR 1910.147(d) · Lockout/tagout
Serious$0$0Sep 1, 2016Final
Citation 1, item 2
29 CFR 1910.212(a)(1) · Machine guarding
Serious$11,224$7,857Sep 1, 2016Final

Inspection 301915252 OPENED APR 1, 1998Closed

Planned · Partial · Safety · 173 employees at the site · Closed Jun 6, 1998

3760 Oakwood Ave., Youngstown, OH 44515 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.101(b) · Compressed gases (general requirements)
Serious$701$420Apr 13, 1998Closed
Citation 1, item 2
29 CFR 1910.157(g)(2) · Portable fire extinguishers
Serious$825$495Apr 13, 1998Closed
Citation 1, item 3a
29 CFR 1910.179(j)(2)(iii) · Overhead and gantry cranes
Serious$825$495Apr 13, 1998Closed
Citation 1, item 3b
29 CFR 1910.179(j)(2)(iv) · Overhead and gantry cranes
Serious$0$0Apr 13, 1998Closed
Citation 1, item 3c
29 CFR 1910.179(m)(1) · Overhead and gantry cranes
Serious$0$0Apr 13, 1998Closed
Citation 1, item 3d
29 CFR 1910.179(n)(4)(i) · Overhead and gantry cranes
Serious$0$0Apr 13, 1998Closed
Citation 1, item 4
29 CFR 1910.217(c)(2)(ia) · Mechanical power presses
Serious$1,375$825Apr 13, 1998Closed
Citation 1, item 5a
29 CFR 1910.217(e)(1)(i) · Mechanical power presses
Serious$825$495Apr 13, 1998Closed
Citation 1, item 5b
29 CFR 1910.217(e)(1)(ii) · Mechanical power presses
Serious$0$0Apr 13, 1998Closed
Citation 1, item 6a
29 CFR 1910.217(e)(3) · Mechanical power presses
Serious$825$495Apr 13, 1998Closed
Citation 1, item 6b
29 CFR 1910.217(f)(2) · Mechanical power presses
Serious$0$0Apr 13, 1998Closed
Citation 2, item 1
29 CFR 1910.217(b)(7)(ix) · Mechanical power presses
Other-than-serious$0$0Apr 13, 1998Closed
Citation 2, item 2a
29 CFR 1910.147(c)(4)(i) · Lockout/tagout
Other-than-serious$0$0Apr 13, 1998Closed
Citation 2, item 2b
29 CFR 1910.147(c)(7)(ib) · Lockout/tagout
Other-than-serious$0$0Apr 13, 1998Closed
Citation 2, item 3
29 CFR 1910.1200(h) · Hazard communication
Other-than-serious$0$0Apr 13, 1998Closed

Inspection 101563518 OPENED MAR 18, 1986Closed

Follow-up · Partial · Safety · 200 employees at the site · Closed Mar 21, 1986

3760 Oakwood Ave., Youngstown, OH 44509 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 214877466 OPENED JAN 20, 1978Closed

Follow-up · Partial · Safety · 212 employees at the site · Closed Mar 10, 1984

3760 Oakwood Avenue, Youngstown, OH 44509 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 214877367 OPENED SEP 30, 1977Closed

Follow-up · Partial · Safety · 180 employees at the site · Closed Jan 20, 1978

3760 Oakwood Avenue, Youngstown, OH 44509 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.217(c)(2)(ic) · Mechanical power presses
Serious$350$350Oct 19, 1977Closed
Citation 2, item 1
29 CFR 1910.22(a)(2) · General requirements
Other-than-serious$0$0Oct 19, 1977Closed
Citation 2, item 2
29 CFR 1910.23(c)(1) · Guarding floor and wall openings and holes
Other-than-serious$0$0Oct 19, 1977Closed
Citation 2, item 3
29 CFR 1910.219(e)(1)(i) · Belts, pulleys and power-transmission parts
Other-than-serious$0$0Oct 19, 1977Closed

Inspection 214976060 OPENED NOV 4, 1976Closed

Follow-up · Partial · Safety · 180 employees at the site · Closed Mar 10, 1984

3760 Oakwood Avenue, Youngstown, OH 44509 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 214965121 OPENED DEC 18, 1974Closed

Follow-up · Complete · Safety · 250 employees at the site · Closed Mar 10, 1984

3760 Oakwood Avenue, Youngstown, OH 44409 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 214964397 OPENED MAY 23, 1974Closed

Planned · Complete · Health · 250 employees at the site · Closed Mar 10, 1984

3760 Oakwood Avenue Po Box 245, Youngstown, OH 44509 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.219(e)(1)(i) · Belts, pulleys and power-transmission parts
Other-than-serious$35$35Jun 11, 1974Closed
Citation 1, item 2 Other-than-serious$50$50Jun 11, 1974Closed

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2025, the Youngstown site logged 12 recordable injuries or illnesses among about 145 workers: 0.1 per 100 full-time workers, against a median of 4.0 for its industry. Those cases cost 84 days away from work.

Site and yearWorkersCasesDays-away casesRateIndustry median
Hynes Industries- Youngstown
Youngstown · 2025
145 12120.14.0
Hynes Industries - Youngstown
Youngstown · 2020
115 545.04.0

Included with any plan: 4 more yearly logs from these sites, back to 2018, with each site's average rate over its latest three years. Already a subscriber? Sign in.

See plans

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.101 · Compressed gases (general requirements)

29 CFR 1910.101(b)

(b) Compressed gases. The in-plant handling, storage, and utilization of all compressed gases in cylinders, portable tanks, rail tankcars, or motor vehicle cargo tanks shall be in accordance with Compressed Gas Association Pamphlet P-1-1965, which is incorporated by reference as specified in § 1910.6.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(h)

(h) Post-mortem data: Increased incidence and/or severity of post-mortem findings may be indicative of maternal toxicity. This can include gross or microscopic pathological findings or organ weight data, including absolute organ weight, organ-to-body weight ratio, or organ-to-brain weight ratio. When supported by findings of adverse histopathological effects in the affected organ(s), the observation of a significant change in the average weight of suspected target organ(s) of treated dams (mothers), compared to those in the control group, may be considered evidence of maternal toxicity.

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.147(c)(4)(i)

(4) Energy control procedure. (i) Procedures shall be developed, documented and utilized for the control of potentially hazardous energy when employees are engaged in the activities covered by this section.

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.179 · Overhead and gantry cranes

29 CFR 1910.212 · Machine guarding

29 CFR 1910.217 · Mechanical power presses

29 CFR 1910.219 · Belts, pulleys and power-transmission parts

29 CFR 1910.22 · General requirements

29 CFR 1910.23 · Guarding floor and wall openings and holes

29 CFR 1910.95 · Noise

Other custom roll forming employers in Ohio

Alert subscribers get notified of each newly cited employer in Ohio the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.