OSHA SearchOSHA records by employer

Iaire LLC: OSHA inspections and violations

Orlando, Florida · Plumbing, Heating, and Air-Conditioning Contractors · NAICS 238220

3inspections
8citation items
$19,691current penalties
Jun 12, 2025last inspection

OSHA has inspected Iaire LLC 3 times in Florida since 2017.

The latest one began on Jun 12, 2025 after a complaint, in Kissimmee; the case is still open.

Those inspections ended with 8 citation items: 7 serious and 1 other-than-serious.

Penalties were first proposed at $30,283 and now stand at $19,691, 35% lower after settlements or reviews.

Respiratory protection comes up most often in these citations: 3 items under 1910.134.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Iaire LLC averages $9,845 (2 cited inspections).

Iaire LLC also files yearly injury logs with OSHA, summarized below.

Iaire LLC: OSHA citation items per year, 2017 to 2025
Citation items per year, by inspection date.

Want to know if OSHA cites Iaire LLC again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 348305525 OPENED JUN 12, 2025Open

Complaint · Partial · Safety · 40 employees at the site · Open

1240 S Hoagland Blvd, Kissimmee, FL 34741 · Commercial, Industrial, and Institutional Electric Lighting Fixture Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.38(f)(3) · Emergency action plans
Serious$4,965$2,979Jul 9, 2025Final
Citation 1, item 1b
29 CFR 1910.157(g)(1) · Portable fire extinguishers
Serious$0$0Jul 9, 2025Final
Citation 1, item 2
29 CFR 1910.253(b)(2)(iv) · Gas welding and cutting
Serious$11,585$6,951Jul 9, 2025Final
Citation 1, item 3
29 CFR 1910.253(b)(4)(iii) · Gas welding and cutting
Serious$9,931$5,959Jul 9, 2025Final
Citation 2, item 1
29 CFR 1910.178(l)(6) · Forklifts and other powered industrial trucks
Other-than-serious$0$0Jul 9, 2025Final

Inspection 347265779 OPENED FEB 7, 2024Closed

Complaint · Partial · Safety · 24 employees at the site · Closed Mar 20, 2024

2100 Consulate Dr., Orlando, FL 32837 · Remediation Services · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 342352424 OPENED MAY 18, 2017Closed

Complaint · Partial · Health · 29 employees at the site · Closed Nov 20, 2017

2100 Consulate Drive, Orlando, FL 32837 · Plumbing, Heating, and Air-Conditioning Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.134(c)(1) · Respiratory protection
Serious$3,802$3,802Aug 23, 2017Final
Citation 1, item 1b
29 CFR 1910.134(c)(1)(ii) · Respiratory protection
Serious$0$0Aug 23, 2017Final
Citation 1, item 1c
29 CFR 1910.134(f)(1) · Respiratory protection
Serious$0$0Aug 23, 2017Final

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2022, the Orlando site logged 0 recordable injuries or illnesses among about 36 workers: 0.0 per 100 full-time workers, against a median of 2.4 for its industry.

Site and yearWorkersCasesDays-away casesRateIndustry median
iAIRE, LLC Florida Plant
Orlando · 2022
36 000.02.4

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.134(c)(1)

(1) The test instrument must have an effective audio-warning device, or a visual-warning device in the form of a screen tracing, that indicates when the test subject fails to hold his or her breath during the test. The test must be terminated and restarted from the beginning when the test subject fails to hold his or her breath during the test. The test subject then may be refitted and retested.

29 CFR 1910.134(c)(1)(ii)

(ii) Medical evaluations of employees required to use respirators;

29 CFR 1910.134(f)(1)

(1) Normal breathing. In a normal standing position, without talking, the subject shall breathe normally.

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.253 · Gas welding and cutting

29 CFR 1910.38 · Emergency action plans

Other plumbing, heating, and air-conditioning contractors employers in Florida