OSHA SearchOSHA records by employer

Ideal Frame Company, Inc.: OSHA inspections and violations

Taylorsville, North Carolina · Nonupholstered Wood Household Furniture Manufacturing · NAICS 337122

8inspections
41citation items
$4,950current penalties
Jan 10, 2020last inspection

Since 1983, OSHA inspectors have visited Ideal Frame Company, Inc. in North Carolina 8 times.

The most recent inspection opened on Jan 10, 2020 to follow up on an earlier case, in Taylorsville.

In all, OSHA issued 41 citation items: 21 serious and 20 other-than-serious.

The proposed penalties came to $7,850; today they stand at $4,950, 37% less.

The rule cited most here is 1910.95 (noise), 9 times.

Among manufacturing employers, the typical cited inspection since 2015 ends with a $3,600 penalty. Ideal Frame Company, Inc. averages $2,850 across 1 cited inspection.

Ideal Frame Company, Inc. also files yearly injury logs with OSHA, summarized below.

Ideal Frame Company, Inc.: OSHA citation items per year, 1983 to 2020
Citation items per year, by inspection date.

North Carolina · latest 90 days of OSHA records

231employers cited

3 of them in the same industry

Get notified the morning OSHA posts each new citation in North Carolina: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in North Carolina

Checking a subcontractor, a client or your own company? Watch Ideal Frame Company, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 344554316 OPENED JAN 10, 2020Closed

Follow-up · Partial · Health · 18 employees at the site · Closed Jan 14, 2020

171 5th Avenue Sw, Taylorsville, NC 28681 · Nonupholstered Wood Household Furniture Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 343932125 OPENED APR 12, 2019Closed

Referral · Partial · Safety · 18 employees at the site · Closed Aug 20, 2019

171 5th Avenue Sw, Taylorsville, NC 28681 · Nonupholstered Wood Household Furniture Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.213(c)(1) · Woodworking machinery
Serious$2,800$2,100Jun 17, 2019Final
Citation 1, item 1b
29 CFR 1910.213(c)(3) · Woodworking machinery
Serious$0$0Jun 17, 2019Final
Citation 1, item 2
29 CFR 1910.219(c)(4)(i) · Belts, pulleys and power-transmission parts
Serious$1,000$750Jun 17, 2019Final

Inspection 316477256 OPENED MAR 29, 2012Closed

Follow-up · Partial · Safety · 40 employees at the site · Closed Apr 5, 2012

171 5th Avenue Sw, Taylorsville, NC 28681 · Showcase, Partition, Shelving, and Locker Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 316259027 OPENED DEC 14, 2011Closed

Complaint · Partial · Safety · 42 employees at the site · Closed Feb 28, 2012

171 5th Avenue Sw, Taylorsville, NC 28681 · Other Millwork (including Flooring) · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.147(c)(5)(i) · Lockout/tagout
Serious$600$400Jan 31, 2012Closed
Citation 1, item 1b
29 CFR 1910.147(d)(2) · Lockout/tagout
Serious$0$0Jan 31, 2012Closed
Citation 1, item 1c
29 CFR 1910.147(c)(7)(ia) · Lockout/tagout
Serious$0$0Jan 31, 2012Closed
Citation 1, item 1d
29 CFR 1910.147(c)(7)(ib) · Lockout/tagout
Serious$0$0Jan 31, 2012Closed
Citation 1, item 2a
29 CFR 1910.213(h)(1) · Woodworking machinery
Serious$600$400Jan 31, 2012Closed
Citation 1, item 2b
29 CFR 1910.213(h)(3) · Woodworking machinery
Serious$0$0Jan 31, 2012Closed
Citation 1, item 3
29 CFR 1910.219(c)(4)(i) · Belts, pulleys and power-transmission parts
Serious$300$100Jan 31, 2012Closed
Citation 1, item 4a
29 CFR 1910.219(d)(1) · Belts, pulleys and power-transmission parts
Serious$600$400Jan 31, 2012Closed
Citation 1, item 4b
29 CFR 1910.219(e)(1)(i) · Belts, pulleys and power-transmission parts
Serious$0$0Jan 31, 2012Closed
Citation 1, item 4c
29 CFR 1910.219(e)(3)(i) · Belts, pulleys and power-transmission parts
Serious$0$0Jan 31, 2012Closed
Citation 2, item 1
29 CFR 1910.178(q)(7) · Forklifts and other powered industrial trucks
Other-than-serious$0$0Jan 31, 2012Closed
Citation 2, item 2
29 CFR 1910.213(a)(1) · Woodworking machinery
Other-than-serious$0$0Jan 31, 2012Closed
Citation 2, item 3
29 CFR 1910.303(b)(2) · Electrical equipment, general requirements
Other-than-serious$0$0Jan 31, 2012Closed

Inspection 314200874 OPENED FEB 8, 2009Closed

Planned · Complete · Health · 25 employees at the site · Closed Sep 20, 2010

171 5th Avenue Sw, Taylorsville, NC 28681 · All Other Miscellaneous Wood Product Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Other-than-serious$0$0Feb 16, 2010Closed
Citation 1, item 2
29 CFR 1910.157(e)(3) · Portable fire extinguishers
Other-than-serious$0$0Feb 16, 2010Closed
Citation 1, item 3
29 CFR 1910.212(b) · Machine guarding
Other-than-serious$0$0Feb 16, 2010Closed

Inspection 311885198 OPENED JAN 30, 2008Closed

Complaint · Partial · Health · 50 employees at the site · Closed Feb 7, 2008

171 5th Avenue Sw, Taylorsville, NC 28681 · Nonupholstered Wood Household Furniture Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 309176576 OPENED JUN 22, 2005Closed

Planned · Complete · Health · 53 employees at the site · Closed Sep 16, 2005

171 5th Avenue Sw, Taylorsville, NC 28681 · Cut Stock, Resawing Lumber, and Planing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a Serious$1,400$500Aug 11, 2005Closed
Citation 1, item 1b Serious$0$0Aug 11, 2005Closed
Citation 1, item 1c Serious$0$0Aug 11, 2005Closed
Citation 1, item 1d Serious$0$0Aug 11, 2005Closed
Citation 1, item 1e Serious$0$0Aug 11, 2005Closed
Citation 1, item 1f Serious$0$0Aug 11, 2005Closed
Citation 1, item 2
29 CFR 1910.212(a)(3)(ii) · Machine guarding
Serious$300$150Aug 11, 2005Closed
Citation 1, item 3
29 CFR 1910.219(f)(3) · Belts, pulleys and power-transmission parts
Serious$250$150Aug 11, 2005Closed
Citation 2, item 1a
29 CFR 1910.147(c)(4)(ii) · Lockout/tagout
Other-than-serious$0$0Aug 11, 2005Closed
Citation 2, item 1b
29 CFR 1910.147(c)(6)(i) · Lockout/tagout
Other-than-serious$0$0Aug 11, 2005Closed
Citation 2, item 2
29 CFR 1910.157(g)(1) · Portable fire extinguishers
Other-than-serious$0$0Aug 11, 2005Closed
Citation 2, item 3
29 CFR 1910.215(b)(9) · Grinders and abrasive wheels
Other-than-serious$0$0Aug 11, 2005Closed
Citation 2, item 4
29 CFR 1910.253(a)(3) · Gas welding and cutting
Other-than-serious$0$0Aug 11, 2005Closed
Citation 2, item 5
29 CFR 1910.303(b)(2) · Electrical equipment, general requirements
Other-than-serious$0$0Aug 11, 2005Closed
Citation 2, item 6
29 CFR 1910.304(e)(1)(via) · Grounding and circuit protection
Other-than-serious$0$0Aug 11, 2005Closed
Citation 2, item 7
29 CFR 1910.304(f)(4) · Grounding and circuit protection
Other-than-serious$0$0Aug 11, 2005Closed
Citation 2, item 8
29 CFR 1910.305(g)(1)(iii) · Electrical wiring methods
Other-than-serious$0$0Aug 11, 2005Closed
Citation 2, item 9
29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods
Other-than-serious$0$0Aug 11, 2005Closed
Citation 2, item 10
29 CFR 1910.334(a)(2)(i) · Using electrical equipment
Other-than-serious$0$0Aug 11, 2005Closed

Inspection 14165070 OPENED OCT 18, 1983Closed

Planned · Complete · Safety · 98 employees at the site · Closed Dec 19, 1983

221 Fifth St Sw, Taylorsville, NC 28681 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.106(g)(8) · Flammable liquids
Other-than-serious$0$0Nov 3, 1983Closed
Citation 1, item 2 Other-than-serious$0$0Nov 3, 1983Closed
Citation 1, item 3 Other-than-serious$0$0Nov 3, 1983Closed

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2018, the Taylorsville site logged 0 recordable injuries or illnesses among about 24 workers: 0.0 per 100 full-time workers, against a median of 3.7 for its industry.

Site and yearWorkersCasesDays-away casesRateIndustry median
Ideal Frame Company Inc.
Taylorsville · 2018
24 000.03.7

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.106 · Flammable liquids

29 CFR 1910.106(g)(8)

(8) Sources of ignition. In addition to the previous restrictions of this paragraph, the following shall apply: There shall be no smoking or open flames in the areas used for fueling, servicing fuel systems for internal combustion engines, receiving or dispensing of flammable liquids. Conspicuous and legible signs prohibiting smoking shall be posted within sight of the customer being served. The motors of all equipment being fueled shall be shut off during the fueling operation.

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.147(c)(4)(ii)

(ii) The procedures shall clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, the following:

29 CFR 1910.147(c)(5)(i)

(5) Protective materials and hardware. (i) Locks, tags, chains, wedges, key blocks, adapter pins, self-locking fasteners, or other hardware shall be provided by the employer for isolating, securing or blocking of machines or equipment from energy sources.

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.212 · Machine guarding

29 CFR 1910.213 · Woodworking machinery

29 CFR 1910.215 · Grinders and abrasive wheels

29 CFR 1910.219 · Belts, pulleys and power-transmission parts

29 CFR 1910.253 · Gas welding and cutting

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.304 · Grounding and circuit protection

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.334 · Using electrical equipment

29 CFR 1910.95 · Noise

Other nonupholstered wood household furniture manufacturing employers in North Carolina

Alert subscribers get notified of each newly cited employer in North Carolina the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.