OSHA SearchOSHA records by employer

Ihr Services, Inc.: OSHA inspections and violations

Des Moines, Iowa · Commercial and Institutional Building Construction · NAICS 236220

3inspections
24citation items
$8,500current penalties
Apr 17, 2017last inspection

Since 2016, OSHA inspectors have visited Ihr Services, Inc. in Iowa 3 times.

The most recent inspection opened on Apr 17, 2017 after a complaint, in Des Moines.

In all, OSHA issued 24 citation items: 22 serious and 2 other-than-serious.

The proposed penalties came to $12,500; today they stand at $8,500, 32% less.

The rule cited most here is 1926.62 (lead in construction), 7 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Ihr Services, Inc. averages $2,833 across 3 cited inspections.

Ihr Services, Inc.: OSHA citation items per year, 2016 to 2017
Citation items per year, by inspection date.

Iowa · latest 90 days of OSHA records

63employers cited

Get notified the morning OSHA posts each new citation in Iowa: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Iowa

Checking a subcontractor, a client or your own company? Watch Ihr Services, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342258373 OPENED APR 17, 2017Closed

Complaint · Partial · Safety · 5 employees at the site · Closed Jan 24, 2018

401 Locust Street, Des Moines, IA 50309 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

Incident on Mar 31, 2017: Employee injures eye when poked by metal wire protruding fro

At approximately 10:30 a.m. on March 31, 2017, an employee was climbing two tier section of scaffolding. The employee climbed the two tier scaffolding without safety glasses on and was standing up on the upper section. He was poked in the eye by metal wire protruding from ceiling. The employee suffered left eye injury and was hospitalized.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.403(i)(2) · Electrical equipment on job sites
Serious$500$500May 9, 2017Final
Citation 1, item 2
29 CFR 1926.405(a)(2)(ii)(f) · Job-site wiring
Serious$500$500May 9, 2017Final
Citation 1, item 3
29 CFR 1926.405(b)(1) · Job-site wiring
Serious$500$500May 9, 2017Final
Citation 1, item 4
29 CFR 1926.501(b)(4)(i) · Fall protection in construction
Serious$875$875May 9, 2017Final
Citation 1, item 5a
29 CFR 1926.502(i)(2) · Fall protection systems
Serious$875$875May 9, 2017Final
Citation 1, item 5b
29 CFR 1926.502(i)(3) · Fall protection systems
Serious$0$0May 9, 2017Final
Citation 1, item 5c
29 CFR 1926.502(i)(4) · Fall protection systems
Serious$0$0May 9, 2017Final
Citation 2, item 1
29 CFR 1904.40(a) · Giving injury records to OSHA
Other-than-serious$250$250May 9, 2017Final
Citation 2, item 2
29 CFR 1904.39(a)(2) · Reporting deaths and severe injuries
Other-than-serious$250$250May 9, 2017Final

Inspection 342112612 OPENED FEB 17, 2017Closed

Complaint · Partial · Health · 4 employees at the site · Closed Apr 20, 2017

401 Locust Street, Des Moines, IA 50309 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.403(i)(2)(i) · Electrical equipment on job sites
Serious$2,000$1,000Mar 28, 2017Final
Citation 1, item 1b
29 CFR 1926.416(a)(1) · Electrical safety in construction
Serious$0$0Mar 28, 2017Final
Citation 1, item 2
29 CFR 1926.405(a)(1)(i) · Job-site wiring
Serious$2,000$1,000Mar 28, 2017Final
Citation 1, item 3
29 CFR 1926.405(b)(2) · Job-site wiring
Serious$2,000$1,000Mar 28, 2017Final
Citation 1, item 4
29 CFR 1926.405(j)(1)(ii) · Job-site wiring
Serious$2,000$1,000Mar 28, 2017Final

Inspection 341927572 OPENED NOV 22, 2016Closed

Complaint · Partial · Health · 7 employees at the site · Closed Jul 26, 2017

401 Locust Street, Des Moines, IA 50309 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.134(c)(1) · Respiratory protection
Serious$125$125Jan 11, 2017Final
Citation 1, item 1b
29 CFR 1910.134(g)(1)(i)(b) · Respiratory protection
Serious$0$0Jan 11, 2017Final
Citation 1, item 1c
29 CFR 1926.62(f)(2)(i) · Lead in construction
Serious$0$0Jan 11, 2017Final
Citation 1, item 2a
29 CFR 1926.62(d)(1)(i) · Lead in construction
Serious$125$125Jan 11, 2017Final
Citation 1, item 2b
29 CFR 1926.62(d)(1)(iii) · Lead in construction
Serious$0$0Jan 11, 2017Final
Citation 1, item 3a
29 CFR 1926.62(d)(2)(v)(b) · Lead in construction
Serious$125$125Jan 11, 2017Final
Citation 1, item 3b
29 CFR 1926.62(g)(1)(i) · Lead in construction
Serious$0$0Jan 11, 2017Final
Citation 1, item 4
29 CFR 1926.62(d)(2)(v)(e) · Lead in construction
Serious$125$125Jan 11, 2017Final
Citation 1, item 5
29 CFR 1926.62(h)(1) · Lead in construction
Serious$125$125Jan 11, 2017Final
Citation 1, item 6
29 CFR 1926.404(b)(1)(i) · Ground-fault protection on job sites
Serious$125$125Jan 11, 2017Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1904.39 · Reporting deaths and severe injuries

29 CFR 1904.39(a)(2)

(2) Within twenty-four (24) hours after the in-patient hospitalization of one or more employees or an employee's amputation or an employee's loss of an eye, as a result of a work-related incident, you must report the in-patient hospitalization, amputation, or loss of an eye to OSHA.

29 CFR 1904.40 · Giving injury records to OSHA

29 CFR 1904.40(a)

(a) Basic requirement. When an authorized government representative asks for the records you keep under part 1904, you must provide copies of the records within four (4) business hours.

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.134(c)(1)

(1) The test instrument must have an effective audio-warning device, or a visual-warning device in the form of a screen tracing, that indicates when the test subject fails to hold his or her breath during the test. The test must be terminated and restarted from the beginning when the test subject fails to hold his or her breath during the test. The test subject then may be refitted and retested.

29 CFR 1926.403 · Electrical equipment on job sites

29 CFR 1926.404 · Ground-fault protection on job sites

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.416 · Electrical safety in construction

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.502 · Fall protection systems

29 CFR 1926.62 · Lead in construction

Other commercial and institutional building construction employers in Iowa

Alert subscribers get notified of each newly cited employer in Iowa the morning it is posted. See the alert plans.