OSHA SearchOSHA records by employer

Indicom Electric Company, LLC: OSHA inspections and violations

Country Club Hills, Illinois · Electrical Contractors and Other Wiring Installation Contractors · NAICS 238210

3inspections
5citation items
$16,000current penalties
Sep 11, 2019last inspection

Indicom Electric Company, LLC has 3 OSHA inspections on record in Illinois, the first in 2006.

OSHA's last visit started on Sep 11, 2019 as part of a related case, in Aurora.

Across those inspections OSHA issued 5 citation items: 5 serious.

OSHA proposed $23,489 in penalties. After settlements and reviews the total is $16,000, down 32%.

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Indicom Electric Company, LLC averages $12,000 over 1 cited inspection in that time.

Indicom Electric Company, LLC: OSHA citation items per year, 2006 to 2019
Citation items per year, by inspection date.

Illinois · latest 90 days of OSHA records

421employers cited

Get notified the morning OSHA posts each new citation in Illinois: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Illinois

Checking a subcontractor, a client or your own company? Watch Indicom Electric Company, LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 344299441 OPENED SEP 11, 2019Closed

Unprogrammed related · Partial · Safety · 1 employee at the site · Closed Mar 2, 2020

600 N. Commerce, Aurora, IL 60504 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Incident on Sep 10, 2019: Two workers are severely burned after arc flash

At 7:00 a.m. on September 10, 2019, two employees were testing electric switch gear. Employee #1, a 55-year-old male, was burned while performing preventative maintenance on 277-600-volt electrical equipment. The equipment included lighting panels and switch gear. The employee received second degree burns to his face, ears and hands as he closed a 600 volt disconnect at the main switch gear. He was not wearing the proper personal protective equipment while performing the work within the restricted flash boundary. This was part of regularly assigned work duties for the employee. Employee #2, an electrician, was in the electrical gear room at the time of the accident. He did not observe the arc flash but was also severely burned. Both employees were hospitalized. Weather did not play a part in the accident as the work was performed indoors in a controlled environment. Language barriers were not identified and did not contribute to the accident.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a Serious$9,282$6,000Nov 25, 2019Final
Citation 1, item 1b
29 CFR 1910.333(a) · Working near live electrical parts
Serious$0$0Nov 25, 2019Final
Citation 1, item 2
29 CFR 1910.335(a)(1)(i) · Safeguards for personnel protection
Serious$9,282$6,000Nov 25, 2019Final

Inspection 311370977 OPENED JAN 18, 2008Closed

Referral · Partial · Safety · 12 employees at the site · Closed Jun 2, 2008

19900 S. Harlem, Frankfort, IL 60423 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.416(a)(3) · Electrical safety in construction
Serious$3,000$3,000Apr 30, 2008Closed

Inspection 309031490 OPENED MAY 23, 2006Closed

Planned · Complete · Safety · 200 employees at the site · Closed Aug 16, 2006

183rd (amphitheater Project), Country Club Hills, IL 60477 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.652(a)(1) · Trench protection
Serious$1,925$1,000Jul 24, 2006Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.332 · Training

29 CFR 1910.332(b)(1)

(b) Content of training—(1) Practices addressed in this standard. Employees shall be trained in and familiar with the safety-related work practices required by §§ 1910.331 through 1910.335 that pertain to their respective job assignments.

29 CFR 1910.333 · Working near live electrical parts

29 CFR 1910.333(a)

(a) General. Safety-related work practices shall be employed to prevent electric shock or other injuries resulting from either direct or indirect electrical contacts, when work is performed near or on equipment or circuits which are or may be energized. The specific safety-related work practices shall be consistent with the nature and extent of the associated electrical hazards.

29 CFR 1910.335 · Safeguards for personnel protection

29 CFR 1910.335(a)(1)(i)

(a) Use of protective equipment—(1) Personal protective equipment. (i) Employees working in areas where there are potential electrical hazards shall be provided with, and shall use, electrical protective equipment that is appropriate for the specific parts of the body to be protected and for the work to be performed.

29 CFR 1926.416 · Electrical safety in construction

29 CFR 1926.652 · Trench protection

Other electrical contractors and other wiring installation contractors employers in Illinois

Alert subscribers get notified of each newly cited employer in Illinois the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.