OSHA has inspected Industrial Neon Sign Corporation 5 times in Texas since 1985.

The latest one began on Jan 17, 2017 as a planned inspection, in Houston.

Those inspections ended with 13 citation items: 6 serious and 7 other-than-serious.

Penalties were first proposed at $8,976 and now stand at $4,448, 50% lower after settlements or reviews.

Hazard communication comes up most often in these citations: 4 items under 1910.1200.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Industrial Neon Sign Corporation averages $3,803 (1 cited inspection).

1 inspection on this page followed a fatal incident.

Industrial Neon Sign Corporation: OSHA citation items per year, 1985 to 2017
Citation items per year, by inspection date.

Texas · latest 90 days of OSHA records

403employers cited

11 of them in the same industry

Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Texas

Checking a subcontractor, a client or your own company? Watch Industrial Neon Sign Corporation and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342029113 OPENED JAN 17, 2017Closed

Planned · Partial · Safety · 6 employees at the site · Closed Nov 28, 2017

7006 I-45, Houston, TX 77087 · All Other Miscellaneous Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.67(c)(2)(iv) · Vehicle-mounted elevating and rotating work platforms
Other-than-serious$3,803$3,803Mar 21, 2017Final
Citation 1, item 1b
29 CFR 1910.67(c)(2)(v) · Vehicle-mounted elevating and rotating work platforms
Other-than-serious$3,803$0Mar 21, 2017Final

Inspection 306478595 OPENED FEB 25, 2004Closed

Planned · Partial · Safety · 10 employees at the site · Closed Feb 25, 2004

2215 Spencer Hwy., Pasadena, TX 77506 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 301402236 OPENED FEB 23, 1998Closed

Planned · Complete · Health · 9 employees at the site · Closed Sep 28, 1998

6223 St. Augustine St., Houston, TX 77021 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.1052(d)(1)(i) · Methylene chloride
Serious$225$225May 18, 1998Closed
Citation 1, item 2
29 CFR 1910.1200(e)(1) · Hazard communication
Serious$375$0May 18, 1998Closed
Citation 1, item 3
29 CFR 1910.1200(g)(1) · Hazard communication
Serious$125$0May 18, 1998Closed
Citation 1, item 4a
29 CFR 1910.1200(h)(2) · Hazard communication
Serious$225$0May 18, 1998Closed
Citation 1, item 4b
29 CFR 1910.1200(h)(3) · Hazard communication
Serious$0$0May 18, 1998Closed
Citation 2, item 1
29 CFR 1910.134(a)(2) · Respiratory protection
Other-than-serious$0$0May 18, 1998Closed

Inspection 101077220 OPENED AUG 13, 1986Closed

Accident · Partial · Safety · 21 employees at the site · Closed Nov 12, 1986

1800 Augusta, Houston, TX 77080 · OSHA's record · Phone and website on Google Maps

Incident on Aug 8, 1986 (fatal): Electric shock - direct contact with energized parts

AN EMPLOYEE WAS ASSIGNED THE JOB OF REPAIRING AN ELECTRIC SIGN THAT WAS REPORTED TO HAVE A LAMP OUT. THE EMPLOYEE HAD THE POWER TO THE SIGN DISCONNECTED; THEN H E REPLACED THE BALLAST. TO SEE IF THE SIGN WAS NOW IN WORKING ORDER, HE CONNECTE D AN EXTENSION CORD SET (WITH ITS GROUNDING CONDUCTOR DISABLED) INTO A 3.5-KILOW ATT VEHICLE-MOUNTED ELECTRIC GENERATOR. HE CUT THE CONDUCTORS AT THE BASE OF THE SIGN AND CONNECTED THEM TO THE EXTENSION CORD CONDUCTORS. THE EMPLOYEE SAW THAT THE LAMP WAS STILL NOT WORKING AND WENT BACK UP IN HIS AERIAL LIFT. HE WAS LATE R FOUND SLUMPED OVER THE AERIAL LIFT BUCKET. HE HAD BEEN ELECTROCUTED.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.304(f)(4) · Grounding and circuit protection
Serious$420$420Aug 27, 1986Closed

Inspection 100268457 OPENED NOV 12, 1985Closed

Planned · Complete · Health · 30 employees at the site · Closed Jan 15, 1986

6223 St Augustine, Houston, TX 77021 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.106(e)(2)(iva) · Flammable liquids
Other-than-serious$0$0Nov 18, 1985Closed
Citation 1, item 2
29 CFR 1910.132(a) · Personal protective equipment, general requirements
Other-than-serious$0$0Nov 18, 1985Closed
Citation 1, item 3
29 CFR 1910.133(a)(1) · Eye and face protection
Other-than-serious$0$0Nov 18, 1985Closed
Citation 1, item 4
29 CFR 1910.151(c) · First aid and eyewash
Other-than-serious$0$0Nov 18, 1985Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1052 · Methylene chloride

29 CFR 1910.1052(d)(1)(i)

(d) Exposure monitoring—(1) Characterization of employee exposure. (i) Where MC is present in the workplace, the employer shall determine each employee's exposure by either:

29 CFR 1910.106 · Flammable liquids

29 CFR 1910.106(e)(2)(iva)

(iv) Handling liquids at point of final use. (a) Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), shall be kept in covered containers when not actually in use.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(e)(1)

(e) Written hazard communication program. (1) Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met, and which also includes the following:

29 CFR 1910.132 · Personal protective equipment, general requirements

29 CFR 1910.133 · Eye and face protection

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.151 · First aid and eyewash

29 CFR 1910.304 · Grounding and circuit protection

29 CFR 1910.67 · Vehicle-mounted elevating and rotating work platforms

Other electrical contractors and other wiring installation contractors employers in Texas

Alert subscribers get notified of each newly cited employer in Texas the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.