Innovative Surfaces Inc: OSHA inspections and violations
Hastings, Minnesota · Cut Stone and Stone Product Manufacturing · NAICS 327991
8inspections
24citation items
$10,260current penalties
Dec 16, 2024last inspection
OSHA has inspected Innovative Surfaces Inc 8 times in Minnesota since 1998.
The latest one began on Dec 16, 2024 as a planned inspection, in Hastings.
Those inspections ended with 24 citation items: 16 serious and 8 other-than-serious.
Penalties were first proposed at $13,800 and now stand at $10,260, 26% lower after settlements or reviews.
Lockout/tagout comes up most often in these citations: 5 items under 1910.147.
How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $4,500, and Innovative Surfaces Inc averages $2,010 (2 cited inspections).
Innovative Surfaces Inc also files yearly injury logs with OSHA, summarized below.
Citation items per year, by inspection date.
Minnesota · latest 90 days of OSHA records
380employers cited
7 of them in the same industry
Get notified the morning OSHA posts each new citation in Minnesota: the employer, the site address, the rules broken and the penalty.
From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.
In 2024, the Hastings site logged 7 recordable injuries or illnesses among about 102 workers: 7.3 per 100 full-time workers, against a median of 2.6 for its industry. Those cases cost 4 days away from work.
Site and year
Workers
Cases
Days-away cases
Rate
Industry median
Innovative Surfaces, Inc.
Hastings · 2024
102
7
2
7.3
2.6
Included with any plan: 6 more yearly logs from these sites, back to 2017, with each site's average rate over its latest three years. Already a subscriber? Sign in.
(ii) Grounding. Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), shall not be dispensed into containers unless the nozzle and container are electrically interconnected. Where the metallic floorplate on which the container stands while filling is electrically connected to the fill stem or where the fill stem is bonded to the container during filling operations by means of a bond wire, the provisions of this section shall be deemed to have been complied with.
(2) The CNP system defaults selected for test pressure shall be set at −15 mm of water (-0.58 inches of water) and the modeled inspiratory flow rate shall be 53.8 liters per minute for performing fit tests.
(4) Energy control procedure. (i) Procedures shall be developed, documented and utilized for the control of potentially hazardous energy when employees are engaged in the activities covered by this section.
Alert subscribers get notified of each newly cited employer in Minnesota the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.