OSHA SearchOSHA records by employer

Innovative Wall Solutions LLC: OSHA inspections and violations

Brookfield, Wisconsin · All Other Specialty Trade Contractors · NAICS 238990

6inspections
18citation items
$21,193current penalties
Aug 12, 2021last inspection

Innovative Wall Solutions LLC has 6 OSHA inspections on record in Wisconsin, the first in 2005.

OSHA's last visit started on Aug 12, 2021 as a planned inspection, in Madison.

Across those inspections OSHA issued 18 citation items: 13 serious, 3 repeat and 2 other-than-serious.

OSHA proposed $38,865 in penalties. After settlements and reviews the total is $21,193, down 45%.

Most often, OSHA cited 1926.451, scaffolds, general requirements (9 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Innovative Wall Solutions LLC averages $6,083 over 3 cited inspections in that time.

Innovative Wall Solutions LLC: OSHA citation items per year, 2005 to 2021
Citation items per year, by inspection date.

Wisconsin · latest 90 days of OSHA records

229employers cited

3 of them in the same industry

Get notified the morning OSHA posts each new citation in Wisconsin: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Wisconsin

Checking a subcontractor, a client or your own company? Watch Innovative Wall Solutions LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 345472187 OPENED AUG 12, 2021Closed

Planned · Partial · Safety · 5 employees at the site · Closed Sep 29, 2025

261 Junction Rd, Madison, WI 53717 · All Other Specialty Trade Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(11) · Fall protection in construction
Serious$4,505$2,252Sep 24, 2021Final
Citation 1, item 2
29 CFR 1926.503(a)(1) · Fall protection training in construction
Serious$3,218$1,609Sep 24, 2021Final
Citation 2, item 1
29 CFR 1926.501(b)(1) · Fall protection in construction
Repeat$9,011$4,506Sep 24, 2021Final
Citation 3, item 1
29 CFR 1903.19(c)(1) · Proving cited hazards were fixed
Other-than-serious$413$413Mar 1, 2023Final
Citation 3, item 2
29 CFR 1903.19(d)(1) · Proving cited hazards were fixed
Other-than-serious$413$413Mar 1, 2023Final

Inspection 344286604 OPENED SEP 5, 2019Closed

Planned · Partial · Safety · 9 employees at the site · Closed Jul 22, 2022

995 S. Pinehurst Ct., Brookfield, WI 53005 · All Other Specialty Trade Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Repeat$6,252$3,751Oct 11, 2019Final
Citation 1, item 1b
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Repeat$0$0Oct 11, 2019Final

Inspection 344039318 OPENED MAY 28, 2019Closed

Planned · Partial · Safety · 12 employees at the site · Closed Apr 8, 2025

20200 Poplar Creek Parkway, Brookfield, WI 53045 · All Other Specialty Trade Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$5,304$2,652Jul 3, 2019Final
Citation 1, item 1b
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$0$0Jul 3, 2019Final
Citation 1, item 1c
29 CFR 1926.451(g)(4)(iv) · Scaffolds, general requirements
Serious$0$0Jul 3, 2019Final
Citation 1, item 1d
29 CFR 1926.451(h)(1) · Scaffolds, general requirements
Serious$0$0Jul 3, 2019Final
Citation 1, item 1e
29 CFR 1926.454(c)(3) · Scaffold training
Serious$0$0Jul 3, 2019Final
Citation 1, item 2a
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$5,304$2,652Jul 3, 2019Final
Citation 1, item 2b
29 CFR 1926.503(c)(3) · Fall protection training in construction
Serious$0$0Jul 3, 2019Final

Inspection 341060382 OPENED NOV 16, 2015Closed

Planned · Partial · Safety · 1 employee at the site · Closed Feb 5, 2016

1729 N Commerce St, Milwaukee, WI 53212 · Drywall and Insulation Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 339118333 OPENED JUN 14, 2013Closed

Unprogrammed other · Partial · Safety · 20 employees at the site · Closed Feb 6, 2015

Trig's 232 S. Courtney St, Rhinelander, WI 54501 · Drywall and Insulation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(e)(6)(i) · Scaffolds, general requirements
Serious$1,445$1,445Jul 1, 2013Final
Citation 1, item 1b
29 CFR 1926.451(e)(8) · Scaffolds, general requirements
Serious$0$0Jul 1, 2013Final

Inspection 309351526 OPENED NOV 2, 2005Closed

Unprogrammed other · Partial · Safety · 9 employees at the site · Closed Jan 5, 2006

4415 W. Loomis, Greenfield, WI 53220 · Painting and Wall Covering Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$1,500$750Nov 23, 2005Closed
Citation 1, item 2
29 CFR 1926.454(a) · Scaffold training
Serious$1,500$750Nov 23, 2005Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1903.19 · Proving cited hazards were fixed

29 CFR 1903.19(c)(1)

(c) Abatement certification. (1) Within 10 calendar days after the abatement date, the employer must certify to OSHA (the Agency) that each cited violation has been abated, except as provided in paragraph (c)(2) of this section.

29 CFR 1903.19(d)(1)

(d) Abatement documentation. (1) The employer must submit to the Agency, along with the information on abatement certification required by paragraph (c)(3) of this section, documents demonstrating that abatement is complete for each willful or repeat violation and for any serious violation for which the Agency indicates in the citation that such abatement documentation is required.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(1)

(b) Scaffold platform construction. (1) Each platform on all working levels of scaffolds shall be fully planked or decked between the front uprights and the guardrail supports as follows:

29 CFR 1926.454 · Scaffold training

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.503 · Fall protection training in construction

Other all other specialty trade contractors employers in Wisconsin

Alert subscribers get notified of each newly cited employer in Wisconsin the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.